• Title/Summary/Keyword: "Effective" block width

Search Result 28, Processing Time 0.028 seconds

Thinning Processor for 160 X 192 Pixel Array Fingerprint Recognition

  • Jung, Seung-Min
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.5
    • /
    • pp.570-574
    • /
    • 2010
  • A thinning algorithm changes a binary fingerprint image to one pixel width. A thinning stage occupies 40% cycle of 32-bit RISC microprocessor system for a fingerprint identification algorithm. Hardware block processing is more effective than software one in speed, because a thinning algorithm is iteration of simple instructions. This paper describes an effective hardware scheme for thinning stage processing using the Verilog-HDL in $160\times192$ Pixel Array. The ZS algorithm was applied for a thinning stage. The hardware scheme was designed and simulated in RTL. The logic was also synthesized by XST in FPGA environment. Experimental results show the performance of the proposed scheme.

A Case Study on the High-quality DCM applied to the Foundation of Breakwater (방파제 기초에 적용된 고품질 DCM공법의 설계 및 시공 사례)

  • Kang, Yeoun-Ike;Shim, Min-Bo;Shim, Sung-Hyun;Kim, Ha-Young;Shim, Jae-Bum;Chun, Youn-Chul;Yoon, Jung-Ik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.815-826
    • /
    • 2009
  • The paper presents a case study addressing the design and construction aspects for DCM(Deep Cement Mixing) method employed as the foundation of a caisson type breakwater with heavy weight(10,700 ton/EA) and a high design wave height($H_{1/3}$=8.7m). The DCM was designed for the project(Ulsan New Port North Breakwater Phase 1) by optimizing the pattern of DCM columns with a combination of short and long columns (i.e., block type(upper 3m)+wall type(lower)) and considering overlapped section between columns as a critical section against shear force where the coefficient of effective width of treated column($\alpha$) was estimated with caution. It was shown that the value can be 0.9 under the condition with the overlapped width of 30cm. In addition to that, a field trial test was performed after improving conventional DCM equipment (e.g., mixing blades, cement paste supplying pipes, multi auger motor, etc.) to establish a standardized DCM construction cycle (withdrawal rate of mixing blades) which can provide the prescribed strength. The result of the field strength test for cored DCM specimens shows that the averaged strength is larger than the target strength and the distribution of the strength(with a defect rate of 7%) also satisfies with the quality control normal distribution curve which allows defect rate of 15.9%.

  • PDF

The Effect of a Piezoelectric Ultrasonic Scaler with Curette Tip on Root Substitute Removal in Vitro (큐렛형 팁을 장착한 압전방식 초음파 치석제거기가 치근대체물 삭제에 미치는 영향)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.429-442
    • /
    • 2000
  • Based on current evidence in the literature, it is known that endotoxin is a weakly adherent surface phenomenon and that power-driven instruments can be used to accomplish definitive root detoxification and maximal wound healing without overinstrumentation of root and without extensive cementum removal. And one of the newly developed curette tips used with low power of piezoelectric ultrasonic scaler, is effective to remove calculus and not to remove the excessive cementum. The purpose of this study is therefore, to assess the influence of ultrasonic power and various working parameters on root substitute removal when instrumentation is performed with the curette tip on piezoelectric ultrasonic scaler. This study assessed defect depth, width and area resulting from instrumentation using a piezoelectric ultrasonic scaler with a curette type tip in vitro to acrylic resin block as a root substitute. The working parameters was standardized by the sledge device which controls lateral force(0.5 N, 1 N, 2 N) and instrumentation time(5 sec, 10 sec, 20 sec) and power setting was adjusted 0,2,4,8 in P mode. Power setting had the greatest influence on defect depth compared to lateral force and instrumentation time(standardized regression parameter estimates${\pm}$standard error, $0.37{\pm}0.02$, $0.19{\pm}0.02$, $0.07{\pm}0.02$). The effects on defect area also greatest for power setting($0.57{\pm}0.03$) compared to lateral force and instrumentation time($0.33{\pm}0.03$, $0.12{\pm}0.03$). The effect of the power setting on the defect width($0.15{\pm}0.01$) is not so great as defect depth or defect area compared to lateral force($0.12{\pm}0.01$) and effect of instrumentation time is minimal($0.02{\pm}0.01$). It could be concluded that the power setting has the greatest influence on the defect depth and area in curette type tip with low power of piezoelectric ultrasonic device. Many parameters can be adjusted in various situation in clinical use of piezoelectric ultrasonic scaler but the power setting is the first parameter to be adjusted.

  • PDF

Drafting Method of Upper Bodice Pattern using 3-D Anthropometric Data for Elderly Women (노년 여성 3-D 입체형상 데이터를 활용한 상반신 원형 설계방법 연구)

  • Suh, Chu-Yeon;Park, Soon-Jee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.5
    • /
    • pp.846-858
    • /
    • 2008
  • This study was designed to propose a method to draft bodice block pattern from 3D body scan data. Subjects were ten elderly women in their 60's, who wear basic size(B: 94cm, W: 82cm) garment. Scanning was done using 3D whole body scanner(WB4, Cyberware). Measurements for 3D data and cross section were attained using Auto CAD, by which a upper bodice pattern for elderly women was drawn on the basis of short measured method. The results are as following: As for most items, no significant differences were shown between measurements from Martin's anthropometry and those from 3D scan data, suggesting measurement from 3D scan data could be used to draft a pattern. The drafting equations acquired were as follows; width of pattern=B/2+5.5, width of waist=W/2+3.5cm, dart amount=8cm. Dart distributions were 23%(B.P.) : 20%(front armpit) : 17%(side seam) : 18%(back armpit) : 15%(back protruded point) : 7% (center back line). Through wearing test using 5-point Likert scale, resultant pattern was evaluated as appropriate for elderly women's pattern to get over 4 point. As a result, it might be said that 3D scanning application is effective for elderly women in that it doesn't take time so much as Martin's anthropometry and that their body shape vary compared with those of young women.

Measurement of Depth Dose Distribution Using Plastic Scintillator

  • Hashimoto, Masatoshi;Kodama, Kiyoyuki;Hanada, Takashi;Ide, Tatsuya;Tsukahara, Tomoko;Maruyama, Koichi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.244-247
    • /
    • 2002
  • We examined a possibility to use inorganic plastic scintillator, which has the effective atomic number close to that of human soft tissue, for the measurement of dose distributions in a shorter time period. The method was to irradiate a block of plastic scintillator as a phantom, and to measure the distribution of the scintillation light by a wave length analyzer through a thread of plastic optical fiber. By irradiating the diagnostic x-ray, we observed the emission spectrum of the scintillation light from the scintillator. It showed a peak at around 420nm with a full width of 140 nm. The emission spectrum was integrated to determine the total number of photons. The dependences of the amount of photons on the irradiated dose were measured. The results of the experiment show that the amount of emission light is in proportional to the irradiated dose. From this fact, we conclude that the present method can be used for the measurement of the depth dose distribution of the diagnostic x-rays.

  • PDF

Printmaking Style Effect using Image Processing Techniques (영상처리 기법을 이용한 판화 스타일 효과)

  • Kim, Seung-Wan;Gwun, Ou-Bong
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.4
    • /
    • pp.76-83
    • /
    • 2010
  • In this paper, we propose a method that converts a inputted real image to a image feeling like printmaking. That is, this method converts a inputted real image to man made rubber printmaking style image using image processing techniques such as spatial filters, image bit-block transfer, etc. The process is as follows. First, after detecting edges in source image, we get the first image by deleting noise lines and points, then by sharpening. Secondly, we get second image using the similar method to the first image. Finally, we blend the first and the second image by logical AND operation This processing enables us to represent rubber panel and knife effects. Also, the proposed method shows that double edge detecting is effective in enhancing line-width and removing the tiny lines.

Microstructure and Magnetic Properties of Nanocomposite Sm2Fe15Ga2Cx/α-Fe Permanent Magnets

  • Cheng, Zhao-hua
    • Journal of Magnetics
    • /
    • v.8 no.1
    • /
    • pp.18-23
    • /
    • 2003
  • In our previous work, microstructure and magnetic properties of two-phase exchange-coupled $Sm_2Fe_{15}Ga_2C_{x}$/$\alpha$-Fe nanocomposites have been investigated by means of x-ray diffraction, transmission electron microscopy and magnetization measurement. It was found the exchange coupling between the magnetically hard phase $Sm_2Fe_{15}Ga_2C_{x}$ and the magnetically soft one ${\alpha}$-Fe results in an enhancement of the remanence. The sizes of crystallites of both phases are, however much larger than the Block domain-wall width of the magnetically hard phase. This microstructure gives rise to a concave demagnetization curve and consequently reduces the maximum energy Product. In order to improve their magnetic properties, a few Percent of Zr, which may be effective to refine the microstructure through rapid quenching, was introduced into the nanocomposites. The addition of Zr was found to improve the magnetic properties significantly, Under optimum heat-treatment conditions, the remanence, coercivity and maximum energy Product increase from 0.65 T, 0.48 T and 50 kJ/$m^{3}$ for the Zr-free sample to 0.72 T, 0.77 T and 71.6 kJ/$m^{3}$ for the 1 at.% Zr-containing one, respectively, The improvements of magnetic properties are due to the refinement of microstructure by the addition of Zr.

Estimation of 3D active earth pressure under nonlinear strength condition

  • Zhang, D.B.;Jiang, Y.;Yang, X.L.
    • Geomechanics and Engineering
    • /
    • v.17 no.6
    • /
    • pp.515-525
    • /
    • 2019
  • The calculation of active earth pressure behind retaining wall is a typical three-dimensional (3D) problem with spatial effects. With the help of limit analysis, this paper firstly deduces the internal energy dissipation power equations and various external forces power equations of the 3D retaining wall under the nonlinear strength condition, such as to establish the work-energy balance equation. The pseudo-static method is used to consider the effect of earthquake on active earth pressure in horizontal state. The failure mode is a 3D curvilinear cone failure mechanism. For the different width of the retaining wall, the plane strain block is inserted in the symmetric plane. By optimizing all parameters, the maximum value of active earth pressure is calculated. In order to verify the validity of the new expressions obtained by the paper, the solutions are compared with previously published solutions. Agreement shows that the new expressions are effective. The results of different parameters are given in the forms of figures to analysis the influence caused by nonlinear strength parameters.

Effects of Mixed Application of Chemical Fertilizer and Liquid Swine Manure on Agronomic Characteristics, Yield and Feed Value of Sorghum × Sudangrass Hybrid for Silage in Paddy Field Cultivation

  • Hwang, Joo Hwan;Lee, Sang Moo
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.34 no.3
    • /
    • pp.155-162
    • /
    • 2014
  • This study was conducted to investigate the influence of the mixed application of chemical fertilizer (CF) and liquid swine manure (LSM) on the agronomic characteristics, dry matter yield, amino acids, minerals, and free sugars in cultivating Sorghum ${\times}$ Sudangrass hybrid (SSH) on paddy soil. The field experiment was designed in a randomized block design with three replications and consisted of CF 100% (C), CF 70% + LSM 30% (T1), CF 50% + LSM 50% (T2), CF 30% + LSM 70% (T3), and LSM 100% treatment (T4). The application of LSM was based solely on the nitrogen. Plant length, leaf length, leaf width and number of leaf were significantly higher in T4 (p<0.05), but stem diameter did not show significant differences among treatments. Stem hardness increased significantly (p<0.05) as the LSM application rate decreased, but sugar degree decreased significantly (p<0.05) as the LSM application rate decreased. Fresh yield, dry matter yield and TDN yield were the highest in T4, whereas the lowest in T2 (p<0.05). Crude protein, crude fat and crude ash were the highest in C, T4 and T2, respectively (p<0.05). However, NDF and ADF did not show significant difference among treatments. Crude fiber decreased significantly (p<0.05) as the LSM application rate increased. The total mineral content was decreased significantly (p<0.05) as the LSM application rate increased. Total amino acid content was higher in the order of T1> C> T3> T4> T2 (p<0.05). Free sugar content increased significantly (p<0.05) as the LSM application rate increased. The analysis of all the above results suggests that the application of liquid swine manure is very effective, considering the yield performance and the content of sugar degree and free sugar. In addition, liquid swine manure may be possible to grow Sorghum ${\times}$ Sudangrass hybrid without chemical fertilizer.

Correction of Recurrent Ingrowing Toenail Using Partial Matricectomy and Paronychial Advancement Flap (부분기질절제술과 발톱주위전진피판을 이용한 재발성 내증식발톱의 교정)

  • Kim, Eui Sik;Kim, Sung Nam;Noh, Bok Kyun;Hwang, Jae Ha;Kim, Kwang Seog;Lee, Sam Yong
    • Archives of Plastic Surgery
    • /
    • v.33 no.3
    • /
    • pp.347-352
    • /
    • 2006
  • Ingrowing toenail has been treated conventionally by various surgical treatment modlities. However, none of these procedures are perfect to achieve esthetic results with low cost, recurrence, and complication rates. Although mild cases can be treated conservatively, in severe recurrent cases, surgical treatment is preferred. The purpose of this study is to evaluate the effectiveness and safety of using partial matricectomy and paronychial advancement flap for correction of recurrent ingrowing toenail. Eight patients suffering from recurrent ingrowing toenail were operated using partial matricectomy and paronychial advancement flap in our department from August 2004 to August 2005. The number of recurrent episodes ranged from 2 to 5. With digital nerve block, the excision area was marked on nailplate and inflammed lateral nail fold. The horizontally designed paronychial flap considering defect size was effective for wide exposure of the neighboring germinal matrix, which is later to be completely excised or cauterized because remnant germinal matrix made postoperative spicule formation. The nailplate on the affected side was removed about 3-5 mm width longitudinally, being cautious not to damage the proximal dorsal nail fold. The same width of the sterile matrix including germinal matrix was excised longitudinally with inflammed granulation tissue and partial lateral nail fold on the affected side. The subcutaneously elevated paronychial flap was advanced to cover the defect and was anatomically sutured with 5-0 nylon sutures. We evaluated our procedure's effectiveness by examining some factors such as cosmetic results, recurrence, spicule formation, postoperative pain and duration of return to normal activities. In eight patients, no complication was observed such as recurrence, severe pain and spicule formation except for 1 case of infection. Postoperative discomfort was minimal. Average duration of return to normal activities was 12 days. Cosmetically the results were acceptable in all patients. The partial matricectomy and paronychial advancement flap for correction of recurrent ingrowing toenail were found to be technically simple, efficient procedure with a relative low recurrence rate and better cosmetic results.