Browse > Article
http://dx.doi.org/10.12989/sem.2017.62.4.391

Effect of rapid screening parameters on seismic performance of RC buildings  

Ozmen, Hayri B. (Department of Civil Engineering, Usak University)
Inel, Mehmet (Department of Civil Engineering, Pamukkale University)
Publication Information
Structural Engineering and Mechanics / v.62, no.4, 2017 , pp. 391-399 More about this Journal
Abstract
This study investigates the effects of soft story, short columns, heavy overhangs, pounding, and construction and workmanship quality parameters on seismic response of reinforced concrete buildings through nonlinear static and dynamic procedures. The accounted parameters are selected for their common use in rapid screening of RC buildings. The 4- and 7-story buildings designed according to pre-modern codes are used to reflect majority of the existing building stock. The relative penalty scores are employed in this study to evaluate relative importance of certain irregularities in the existing rapid seismic assessment procedures. Comparison of relative scores for the irregularities considered in this study show that the overall trend is similar. The relatively small differences may be accounted for regional construction practices. It is concluded that initial-phase seismic assessment procedures based on architectural features yield in somewhat similar results independent of their bases. However, the differences in the scores emphasize the proper selection of the method based on the regional structure characteristics.
Keywords
existing buildings; irregularity; mid-rise; seismic assessment; pounding; reinforced concrete;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 TS500 (2000), Design and construction specifications for reinforced concrete structures, Turkish Standards Institute, Ankara, Turkey.
2 Turkish Earthquake Code (TEC) 1975 Specifications for buildings to be built in seismic areas. Ministry of Public Works and Settlement, Ankara, Turkey.
3 Turkish Earthquake Code (TEC) 2007 Specifications for buildings to be built in seismic areas. Ministry of Public Works and Settlement, Ankara, Turkey.
4 UBC (1997), Uniform Building Code (1997), International Conference of Building Officials (ICBO), California: Whittier.
5 Vimala, A. and Kumar, R.P. (2016), "Estimation of energy dissipation capacity of a structure using pushover analysis", Ind. Concrete J., 90(4), 72-77.
6 Yakut, A. (2004), "Preliminary seismic assessment procedure for existing RC buildings", Eng. Struct., 26(10), 1447-1461.   DOI
7 Yon, B., Sayin, E., Calayir, Y., Ulucan, Z.C., Karatas, M., Sahin, H., ... and Bildik, A.T. (2015), "Lessons learned from recent destructive Van, Turkey earthquakes", Earthq. Struct., 9(2), 431-453.   DOI
8 Akbas, B., Tugsal, U.M. and Kara, F.I. (2009), "An evaluation of energy response and cumulative plastic rotation demand in steel moment-resisting frames through dynamic/static pushover analyses", Struct. Des. Tall Spec., 18(4), 405-426.   DOI
9 ATC-40 (1996), Seismic Evaluation and Retrofit of Concrete Buildings, Applied Technology Council, Redwood City, California.
10 Bilgin, H. (2015), "Generation of fragility curves for typical RC health care facilities: emphasis on hospitals in Turkey", J. Perform. Constr. Facil., 30(3), 04015056.
11 Building Census 2000 (2001), State Institute of Statics Prime Ministry of Turkey, Ankara, Turkey.
12 Cirak, I.F., Kaplan H., Yilmaz S., Degirmenci O.D. and C etinkaya N. (2015), "A model for shear behavior of anchors in external shear walled frames", Res. Eng. Struct. Mater., 1, 53-71.
13 Elnashai, A.S., Papanikalaou, V. and Lee, D.H. (2006), ZeusNL: A System for Inelastic Analysis of Strutures.
14 FEMA-154 (1988), Rapid Visual Screening of Buildings for Potential Seismic Hazards: A Handbook, Federal Emergency Management Agency, Washington.
15 FEMA-154 (2002), Rapid Visual Screening of Buildings for Potential Seismic Hazards: A Handbook, Federal Emergency Management Agency, Washington.
16 FEMA-307 (1998), Evaluation of Earthquake Damaged Concrete and Masonry Wall Buildings, Federal Emergency Management Agency, Washington.
17 Inel, M. and Meral, E. (2016), "Seismic performance of RC buildings subjected to past earthquakes in Turkey", Earthq. Struct., 11(3), 483-503.   DOI
18 FEMA-310 (1998), Handbook for the Seismic Evaluation of Buildings-A Prestandard, American Society of Civil Engineers for the Federal Emergency Management Agency, Washington, D.C
19 FEMA-356 (2000), Prestandard and Commentary for Seismic Rehabilitation of Buildings, Federal Emergency Management Agency, Washington, D.C.
20 Gunes, O. (2015), "Turkey's grand challenge: Disaster-proof building inventory within 20 years", Case Stud. Constr. Mater., 2, 18-34.   DOI
21 Inel, M., Bilgin, H. and Ozmen, H.B. (2008), "Seismic capacity evaluation of school buildings in Turkey", Proceedings of the Institution of Civil Engineers-Structures and Buildings, 161(3), 147-159.   DOI
22 Inel, M., Ozmen, H.B. and Akyol, E. (2013), "Observations on the building damages after 19 May 2011 Simav (Turkey) earthquake", B. Earthq. Eng., 11(1), 255-283.   DOI
23 Licari, M., Sorace, S. and Terenzi, G. (2015), "Nonlinear modeling and mitigation of seismic pounding between R/C frame buildings", J. Earthq. Eng., 19(3), 431-460.   DOI
24 Lim, H.K., Kang, J.W., Lee, Y.G. and Chi, H.S. (2016), "Seismic performance evaluation of a three-dimensional unsymmetrical reinforced concrete building", Multisc. Multiphys. Mech., 1(2), 143-156.   DOI
25 Mander, J.B. (1984), "Seismic design of bridge piers", Ph.D. Dissertation, University of Canterbury, New Zealand.
26 Ozmen, H.B., Inel, M. and Cayci, B.T. (2013), "Engineering implications of the RC building damages after 2011 Van Earthquakes", Earthq. Struct., 5(3), 297-319.   DOI
27 Ohkubo, M. (1991), "Current Japanese system on seismic capacity and retrofit techniques for existing reinforced concrete buildings and post-earthquake damage inspection and restoration techniques", Report No. SSRP-91/02, Department of Applied Mechanics and Engineering Sciences, University of California, San Diego.
28 Otani S. (1997), "Lessons learned from past earthquakes", Proceedings of the 4th Turkish National Conference on Earthquake Engineering, Ankara, Turkey.
29 Ozcebe, G. (2004), "Seismic assessment and rehabilitation of existing buildings", Tubitak Research Report. No: ICTAG YMAU I574, Ankara, Turkey
30 Ozdemir, G. and Bayhan, B. (2015), "Response of an isolated structure with deteriorating hysteretic isolator model", Res. Eng. Struct. Mater., 1(1), 1-10.
31 Ozmen, H.B., Inel, M., Senel, S.M. and Kayhan, A.H. (2015), "Load carrying system characteristics of existing Turkish RC building stock", Int. J. Civil Eng., 13(1), 76-91.
32 Park, R. and Paulay, T. (1975), Reinforced Concrete Structures, John Wiley & Sons, New York
33 SAP2000, Computers and Structures Inc., Integrated finite element analysis and design of structures basic analysis reference manual. Berkeley, CA, USA.
34 Park, R., Priestly, M.J.N. and Gill, W.D. (1982), "Ductility of square confined concrete columns", J. Struct. Eng., 108(4), 929-950.
35 Priestley, M.J.N., Seible, F. and Calvi, G.M.S. (1996), Seismic Design and Retrofit of Bridges, John Wiley & Sons, New York.
36 Santiago, P., Ramirez, J. and Sarria, A. (2003), Observations on the behaviour of low-rise reinforced concrete buildings January 25 Colombia Earthquake, http://nisee.berkeley.edu/lessons/colombia.pdf.
37 Scott, B.D., Park, R. and Priestley, M.J.N. (1982), "Stress-strain behavior of concrete confined by overlapping hoops at low and high strain rates", ACI Struct. J., 76(1), 13-27.
38 TS 498 (1987), Design Loads for Buildings, Turkish Standards Institute, Ankara, Turkey.
39 Tama, Y.S. (2012), "Structural damages observed in state buildings after Simav/Turkey Earthquake occurred on 19 May 2011", Nat. Hazard. Earth Syst. Sci, 12, 2709-2718.   DOI