Effect of Metals used in Orthopedic on Magnetic Resonance Imaging II  

Kim, Hyeong-Gyun (금오공과대학교 대학원 지능기계공학과)
Choi, Seong-Dae (금오공과대학교 지능기계공학과)
Publication Information
Journal of the Korean Society of Manufacturing Process Engineers / v.11, no.5, 2012 , pp. 115-120 More about this Journal
Abstract
Metals used orthopedic in human magnetic resonance imaging scan of the metal to be inserted, The information to users about the image distortion is to propose a basis for judgment. Metals used orthopedic on Stainless, Titanium and Clip using ferromagnetic artifacts and distortion of the image were measured. Using Phantom "Effect of Metals used in Orthopedic on Magnetic Resonance ImagingI" pig in a paper subsequently was carried out using the same bone. Experimental results using a pure Titanium is a relatively high diagnostic value was found that.
Keywords
MRI; Orthopedic; Bone; Image Distortion; Implant Metal; T2WI; T1WI;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Kim Hyeong Gyun et al, "Effect of Metals used in Orthopedic on Magnetic Resonance Imaging I". Journal of the Korean Society of Manufacturing Process Engineers, Vol. 11 No. 4, pp. 46-50, 2012.
2 Shellock FG, Morisoli S, Kanal E, MR procedures and biomedical implants, materials, and devices:1993updates. Radiology, Vol. 189, pp. 587-599, 1993.   DOI
3 Shellock FG, MR imaging of metallic implants and materials: a complication of the literature. AJR, Vol. 151, pp. 811-814, 1998.
4 New PJ, Rosen BR. Brady TJ et al., Potential Hazards and Artiacts of Ferromagnetic Surgical and Dental Materials and Devics in Nuclear Magnetic Resonance Imaging, Radiology 147:139-148, 1983.   DOI
5 Davis PL. Crooks L. Arakawa M et al., Potential Hazards in NMR Imaging : Heating effects of Changing Magnetic Field and RF fields on Small Metallic Implants, AJR 137 : 857-860, 1981.   DOI
6 Shellock FG, Crues JV, High-field strength MR image and metallic biomedical implants: an ex vivo evaluation of deflection forces, AJR. Vol. 151, pp. 389-392, 1988.   DOI
7 Hong Hyun Sook et al., Artifacts of Biomedical Implants on Magnetic Resonance Imaging, Korea Journal Vol. 29, No. 1. 1992.
8 Hong Hyun Sook et al., Artifacts of Biomedical Implants on Magnetic Resonance Imaging, Korea Journal Vol. 29, No. 1. 1992.
9 Lee Sung Woo, The newest magnetic resonance imaging studies, Ryo Moon Gak, pp. 288-289, 1998.
10 Farahani K, Sinha U, Sinaha S, Chiu LC, Lufkin RB, Effect of field strength on susceptibility artifacts in magnetic resonance imaging Comput Med Imaging Graph, Vol. 14, pp. 409-413, 1990.   DOI
11 Park Yong Hun et al., A research on Metallic susceptibility Artifact according to the Magnet Depth type, Journal of The Korean Society of MR Technology, Vol. 19, pp. 45-52, 2009.