Browse > Article

A Dipstick-Type Electrochemical Immunosensor for The Detection of The Organophosphorus Insecticide Fenthion  

Cho, Young-Ae (Department of Food Science and Nutrition, Kyungpook National University)
Cha, Geun-Sig (Department of Chemistry, Kwangwoon University)
Lee, Yong-Tae (Department of Biochemistry, and Institute of Natural Sciences, Yeungnam University)
Lee, Hye-Sung (Department of Food Science and Nutrition, Kyungpook National University)
Publication Information
Food Science and Biotechnology / v.14, no.6, 2005 , pp. 743-746 More about this Journal
Abstract
A dipstick-type immunochemical biosensor for the detection of the organophosphorus insecticide fenthion was developed using a screen-printed electrode system as an amperometric transducer with polyclonal antibodies against fenthion as a bioreceptor. The assay of the biosensor involved competition between the pesticide in the sample and pesticide-glucose oxidase conjugate for binding to the antibody immobilized on the membrane. This was followed by measurement of the activity of the bound enzyme by the supply of the enzyme substrate (glucose) and amperometric determination of the enzyme reaction product ($H_2O_2$). The activity of the bound enzyme was inversely proportional to the concentration of pesticide. The optimized sensor system showed a linear response against the logarithm of the pesticide concentration ranging from $10^{-2}$ to $10^3\;{\mu}g/L$.
Keywords
fenthion; organophosphorus insecticide; amperometry; immunosensor; dipstick;
Citations & Related Records

Times Cited By Web Of Science : 3  (Related Records In Web of Science)
연도 인용수 순위
  • Reference
1 AOAC. Official Methods of Analysis, 18th ed. Section 970.52. Association of Official Analytical Communities, Arlington, VA, USA (1995)
2 Synthesis of haptens for immunoassay of organophosphorus pesticides and effect of heterology in hapten spacer arm length on immunoassay sensitivity /
[ Kim, Y.J.;Cho, Y.A.;Lee, H.S.;Lee, Y.T.;Gee, S.J.;Hammock, B.D. ] / Anal. Chim. Acta
3 Development of a microtiter plate ELISA and a dipstick ELISA for the determination of the organophosphorus insecticide fenthion /
[ Cho, Y.A.;Kim, Y.J.;Hammock, B.D.;Lee, Y.T.;Lee, H.S. ] / J. Agric. Food Chem.
4 Official Methods of Analysis /
[ AOAC ] /
5 Strengths and limitations of immunoassays for effective and efficient use for pesticide analysis in water samples: A review /
[ Hennion, M.C.;Barcelo, D. ] / Anal. Chim. Acta.
6 A disposable amperometric immunosensor for 2,4-dichlorophenoxyacetic acid /
[ Kalab, T.;Sklidal, P. ] / Anal. Chim. Acta
7 Development of a new immuno?sensor for pesticide detection: a disposable system with liposomeenhancement and amperometric detection /
[ Baumner, A.J.;Schmid, R.D. ] / Biosens. Bioelectron
8 Separation-free electrochemical immunosensor for rapid determination of atrazine /
[ Keay, R.W.;McNeal, C.J. ] / Biosens. Bioelectron
9 Application of screen-printed electrodes as transducers in affinity flow-through sensor systems /
[ Fernandez Romero, J.M.;Stiene, M.;Luque de castro, M,D.;Bilitewski, U. ] / Biosens. Bioelectron.
10 Polychlorinated biphenyls (PCBs) detection in food samples using an electrochemical immunosensor /
[ Laschi, S.;Mascini, M.;Scortichini, G.;Franek, M.;Mascini, M. ] / Agric. Food Chem.
11 Development of a sensitive, selective electrochemical immunoassay for progesterone in cow's milk based on a disposable screen-printed amperometric biosensor /
[ Pemberton, R.M.;Hart, J.P.;Foulkes, J.A. ] / Electrochim. Acta
12 A separation free amperometric immunosensor for vitellogenin based on screen-printed carbon arrays modified with a conductive polymer /
[ Darain, F.;Park, O.S.;Park, J.S.;Chang, S.C.;Shim, Y.B. ] / Biosens. Bioelectron.
13 The Pesticide Manual: A World Compendium;The British Crop Protection Council /
[ Tomlin, C.D.S. ] /