In the last few years, a considerable number of studies have been made on On-Off solenoid for fluid control. But, only few attempts have so far been made at solenoid actuator for high-voltage circuit breaker. In case of the high-pressure and high-flow system like high-voltage circuit breaker, a big size of On/Off solenoid is necessary which size is proportional to control pressure and flow rate. So, it is non-effective in the view point of system optimization. In this paper, On/Off solenoid actuator with the farce amplifier connected to the solenoid rod was proposed to get a high mechanical force and a fast response time. The magnetic force and the mechanical stress distributions were analysed using finite element analysis. The performances of suggested solenoid actuator were evaluated through the experimental results and compared with the analysis results.