• Title/Summary/Keyword: Complete dentures

Search Result 157, Processing Time 0.026 seconds

FACTORS INFLUENCING PATIENT SATISFACTION WITH COMPLETE DENTURES (총의치 환자 만족도의 영향요인)

  • Lee Suk-Won;Chung Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.633-649
    • /
    • 2005
  • Statement of problem: In spite of the progress in techniques and materials in complete denture prosthodontics, patients still complain of discomfort after the insertion of complete dentures. For the last several decades many prosthodontists tried to find factors influencing patient complete denture satisfaction, however the reported results became a controversy. Purpose: The purpose of the present study was to verify the factors influencing patient satisfaction with complete dentures using multiple regression analysis. Materials and methods: 33 patients who visited the department of prosthodontics, dental hospital of Yonsei University, 4 to 6 weeks after the complete denture delivery, were asked to complete the questionnaires on complete denture satisfaction, social variables and psychological variables. The Prosthodontists who treated the patients with complete dentures were also asked to complete the questionnaires on evaluation of patients' oral condition and technical quality of dentures. The factors influencing patients' satisfaction with their complete dentures were analyzed using multiple regression analysis. Results: Among the patients' sociodemographic variables. the variables of relationship with children, economic status, housing condition, other people's opinions of dentures and gender were the influential factors on patients' satisfaction with complete dentures. Patients showing the symptoms of depression, one of the psychological variables, were dissatisfied with their complete dentures. In spite of the good oral condition, patients were dissatisfied with complete dentures, where-as the technical quality of dentures did not influence patients' complete denture satisfaction. Conclusion : According to the results above, patients' sociodemographic and psychological variables rather than clinical variables including oral condition and technical quality of dentures were the influential factors on complete denture satisfaction. The results of this study may not only enable prosthodontists to predict the success and failure of complete denture treatment, but also help both prosthodontists and patients be informed of the essentials of increasing satisfaction with complete dentures.

PSYCHOLOGICAL ASPECT OF PATIENT SATISFACTION AND ACCEPTANCE OF COMPLETE DENTURES (총의치 환자 만족도에 대한 정신의학적 측면)

  • Chung, Moon-Kyu;Lee, Suk-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.494-505
    • /
    • 1999
  • In spite of the progress in techniques and materials of the prosthodontic rehabilitation of patients with complete edentulous arches, prosthodontists still face patients' complaints about dissatisfaction and discomfort from their dentures. In the past several decades, prosthodontists tried to find the factors that influence the patient's satisfaction with dentures. However the results are contraversial especially with the psychological factor. In this study using 'patient denture satisfaction questionnaire' and Hopkins Symptom Checklist, we tried to find the correlation between the patient's denture satisfaction and the patient's psychological aspects. 23 complete edentulous patients who have visited the Department of Prosthodontics, Yonsei University Dental Hospital from September 1998 to June 1999 for complete denture treatment were asked to complete the questionnaires 4 to 6 weeks after the upper and lower complete delivery. After the measurement of validity of the questionnaires, correlations between the patient's general satisfaction with their new upper and lower complete dentures and the other satisfaction questions including the satisfactions with esthetics, retention, mastication, speech, comfort and other people's opinion and between the patient's general satisfaction with their new upper and lower complete dentures and the 5 symptoms of Hopkins Symptoms Checklist including somatic, obsessive-compulsive, interpersonal sensitivity, depression and anxiety were analyzed. Among the several satisfaction questionnaire items, comfort with the lower denture showed highest relation to the patient's general satisfaction with dentures. However, only the anxiety scale of Hopkins Symptoms Checklist among the other symptom scales was related to the patient's general satisfaction with dentures. The two questionaires used in this study turned out to be valid means of analyzing patient's denture satisfaction and psychological status before and after the complete denture treatment.

  • PDF

Factors influencing the frequency of denture adjustments after delivery of complete denture: a retrospective study (총의치 장착 후 의치 조정 횟수에 영향을 미치는 요인에 관한 후향적 연구)

  • Lee, Seungwon;Yoon, Joon-Ho;Yoo, Jin-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.239-245
    • /
    • 2022
  • Purpose. The purpose of this study was to analyze the frequency and duration of adjustments after delivery of complete denture according to age, sex, arch with complete denture, insurance coverage of a denture, type of antagonist, the experience of wearing denture, the period of edentulism, and the type of denture base. Materials and methods. For 5 years, medical records of patients aged 65 or older who had treated full dentures were assessed for the frequency and duration of follow-up visits after complete denture delivery. Statistical analysis was performed at the 5% level of significance to analyze the correlation between the frequency and duration of follow-up according to sex, insurance coverage, arch with the complete denture, type of denture base, type of antagonist, experience of wearing a denture, age, and healing period. Results. 247 complete dentures were included in this study. The median frequency of follow-up visits was 3, and the median duration of follow-up was 36 days. Lower dentures had significantly higher frequency of follow-up visits than upper dentures (P = .036). According to the type of antagonist, dentures opposing a complete denture had a significantly higher frequency of follow-up visits than dentures opposing a removable partial denture (P = .016). There was no statistically significant difference in the frequency and duration of adjustments after delivery of complete denture by age, sex, insurance coverage, healing period, the experience of wearing a denture, and type of denture base. Conclusion. Within the limitations of the present study, lower complete dentures or dentures opposing a complete denture had an increased frequency of follow-up visits.

Adherence of Candida to complete denture surfaces in vitro: A comparison of conventional and CAD/CAM complete dentures

  • Al-Fouzan, Afnan F.;Al-mejrad, Lamya A.;Albarrag, Ahmed M.
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.5
    • /
    • pp.402-408
    • /
    • 2017
  • PURPOSE. The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. MATERIALS AND METHODS. Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. RESULTS. There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure (P<.05). CONCLUSION. The CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures.

Analysis of curriculum related to subjects of Korean Dental Technicians' Licensing Examination (국가고시 교과목에 따른 치기공과 교육과정의 분석)

  • Bae, Bong-Jin;Lee, Hwa-Sik
    • Journal of Technologic Dentistry
    • /
    • v.28 no.2
    • /
    • pp.399-415
    • /
    • 2006
  • This research collected the curriculum for Dental Technology from a total of 20 schools-eighteen 3-year colleges and two 4-year colleges all in Korea. We divided 4 groups as regions from 20 colleges, and we compared the credit of university students who finished all the required courses and want to apply for a national examination and the credit to be had from another educational institution. As a result of this analysis, we get the conclusion below: 1. In the curriculum, average credit are shown like this order: Science of Dental materials 5.45 Orthodontics Technology 4.10 Dental Morphology 3.80 Oral Anatomy 3.05 Dental Health Science 2.45 Public Health Science 2.40 These show that the credit of fundamental studies, which is in order to take Dental Prosthetics, is increased. 2. In the curriculum, average credit are shown like this order: Crown and Bridge Technology 7.25 Removable Partial Dentures Technology 6.55 Complete Dentures Technology 6.40 Dental Ceramics 4.95 Inlay Technology 2.30 3. In the curriculum, average credit are shown like this order: Crown and Bridge Technology(Lab) 5.90 Removable Partial Dentures Technology(Lab) 5.35 Complete Dentures Technology(Lab) 5.30 Dental Ceramics(Lab) 4.35 Average points between regions in the subject of a national written exam are mostly similar, but the deviation among Science of Dental Materials, Crown and Bridge Technology, Removable Partial Dentures Technology, and Complete Dentures Technology is large. And in the practical technique exam, the deviation among Crown and Bridge Technology(Lab), Removable Partial Dentures Technology(Lab), and Complete Dentures Technology(Lab) is great.

  • PDF

Complete denture rehabilitation of edentulous patient using mandibular suction denture: a clinical report (완전 무치악 환자에서 하악 흡착 의치를 통한 총의치 수복 증례)

  • Lim, Seo-Ryeon;Seo, Yoon-Hee;Kim, Hyun-Young;Song, Young-Gyun;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.346-351
    • /
    • 2014
  • Suction dentures enhance retention and support by forming negative pressure temporarily at the internal surface of denture base at times of swallowing and chewing because the areas surrounding the denture flanges are sealed by mobile mucosa. In this case, an 81-year-old male visited for new dentures. Considering the high expectations for retention and masticatory efficiency of dentures, fabricating complete dentures with suction dentures was planned. Preliminary impression was taken without applying pressure on retromolar pad area and diagnostic cast was fabricated. Afterwards, individual tray was made and final impression was taken, at the same time, gothic arch tracing was done to acquire centric relation and vertical dimension. Then, anatomic teeth were placed on maxilla and non-anatomic teeth were placed on mandible forming lingualized occlusion. Consequently, restoring a complete edentulous patient with complete dentures using mandibular suction denture resulted in recovering satisfying retention and function.

Precision evaluation of impression surface of lower complete dentures reinforced with glass fiber (유리섬유 보강재를 삽입한 하악 레진의치 인상면의 정밀성 평가)

  • Kim, Dong-Yeon;Yang, Cheon-Seung;Lee, Gwang-Young;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.42 no.1
    • /
    • pp.27-33
    • /
    • 2020
  • Purpose: This study is to compare and analyze the precision of glass fiber resin dentures. Methods: A lower edentulous model was prepared. Ten study models were produced using Type IV stone. Ten wax lower resin dentures containing artificial teeth were prepared. The lower wax denture was buried with plaster and deflasking was performed to remove the wax. Five conventional lower resin dentures and five glass fiber lower resin dentures were produced. The scanning spray was coated on the impression surface and then scanned. Independent sample t-test were performed using statistical software. Results: In the color different map, which is a qualitative evaluation, the green area of the precision of the conventional lower resin denture occupied the whole. The glass fiber conventional resin dentures had many negative and positive area. In quantitative evaluation, the RMS of conventional lower resin was 89.83 ㎛ and that of fiberglass resin was 224.92 ㎛. The two groups showed statistically significant differences (p<0.05). Conclusion: Conventional lower resin dentures were superior in precision, and glass fiber resin dentures would have to improve the process.

Acoustic Characteristics of Patients with Maxillary Complete Dentures (상악 총의치 장착 환자 언어의 음향학적 특성 연구)

  • Ko, Sok-Min;Hwang, Byung-Nam
    • Speech Sciences
    • /
    • v.8 no.4
    • /
    • pp.139-156
    • /
    • 2001
  • Speech intelligibility in patients with complete dentures is an important clinical problem depending on the material used. The objective of this study was to investigate the speech of two edentulous subjects fitted with a complete maxillary prosthesis made of two different palatal materials: chrome-cobalt alloy and acrylic resin. Three patients with complete dentures in the experiment group and ten people in the controls groups participated in the experiment. CSL, Visi-Pitch were used to measure speech characteristics. The test words consisted of a simple vowel /e/, meaningless three syllabic words containing fricative, affricated and stops sounds, and sustained fricative sounds /s/ and /$\int$/. The analysis speech parameters were vowel and lateral formants, VOT, sound durations, sound pressure level and fricative frequency. Data analysis was conducted by a series of paired T-test. The findings like the following: (1) Vowel formant one of patients with complete denture is higher than that of the control group (p<0.05), while lateral formant three of patients with complete denture is lower than that of the control group (p<0.0l). (2) Patients with complete denture produced lower speech intelligibility with low fricative frequency (/$\int$/) than control group (p<0.0). The speech intelligibility of patients with metal prosthesis was higher than that of those with resin prosthesis (p<0.05). (3) Fricative, lateral and stop sound durations of patients with complete denture were longer than those of the control group (p<0.01 and p<0.05), respectively. Total sound durations of patients with metal prosthesis were similar to that of the control group (p<0.05), while those with resin prosthesis had a shorter duration (p<0.01). This implied that those with metal prosthesis had higher speech intelligibility than those with resin prosthesis. (4) Patients with complete denture had higher sound pressure levels /t/ and /c/ than the control group (p<0.01). However, sound pressure levels for /c/ of patients with metal prosthesis or resin prosthesis was similar to the control group (p<0.05). (5) Patients with complete denture had higher fundamental frequency than the control group (p<0.01).

  • PDF

Comparative evaluation of two sets of complete dentures fabricated by digital and conventional workflow in a single patient: A case report (단일 환자에서 디지털 및 전통적인 워크플로우로 제작한 두 쌍의 총의치를 장착하여 비교평가한 증례 보고)

  • Kim, Sang Hyun;Oh, Kyung Chul;Park, Ji Man;Kim, Jee Hwan;Moon, Hong Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.350-358
    • /
    • 2021
  • Application of digital technology in dental treatments can simplify the treatment process and reduce patient discomfort. In regards of digital complete dentures, several commercial systems are available. However, these systems are not being routinely applied in Korea. In this case report, comparative analyses were performed regarding the two sets of complete dentures fabricated in digital and conventional workflow in a single patient. Complete dentures made with digital workflow were able to form an ideal occlusion because customized teeth were used. Compared to that, there were also limitations such as lower retention of mandibular dentures, so we would like to report this.

Prosthodontic management of worn dentition in pediatric patient with complete overlay dentures: a case report

  • Kumar, Prince;Rastogi, Jyoti;Jain, Chandni;Singh, Harkanwal Preet
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.239-242
    • /
    • 2012
  • Overlay complete dentures are simple, reversible and economical treatment modality for patients with congenital or acquired disorders that severely affect the tooth development. It satisfies both the esthetic and functional demands where the extraction of teeth is not generally indicated. In pediatric patients, the overlay dentures establish a relatively stable occlusion that improves patient's tolerance to the future treatment procedures for worn dentition. This clinical report highlights the imperative need of appropriate treatment strategy and application of maxillary and mandibular overlay dentures in a pediatric patient who suffered from congenitally mutilated and worn dentition.