Abstract

The digital facebow device records the trajectory of the mandibular movement where it is then reflected on the computer-aided design software, leading to an improvement on treatment outcomes of prosthetic restorations. In this clinical case, using a digital technology, an implant placement and prosthetic restoration were done in a patient who has lost maxillary and mandibular molars. Following an intraoral scan, a surgical stent for implant surgery was fabricated based on digital diagnostic wax-up, and implants were installed. After six months of sufficient osseointegration, customized abutments and the first temporary prostheses were delivered. Then two months later, at an abutment level, an intraoral scan and digital facebow transfer device were used to mount the intraoral scan data on a virtual articulator, and record the mandibular movements. Once the second temporary prostheses were fabricated and delivered on a basis of the mandibular movement, the definitive zirconia prostheses were designed and delivered based on a stabilized occlusion that was duplicated via double scan technique.

디지털 안궁이전 장치로 하악의 운동로를 기록하고 캐드 소프트웨어(CAD software) 상에 반영할 수 있는데 이를 고려한 보철 수복은 치료 결과를 향상시킨다. 본 증례는 상하악 대구치가 소실된 환자에서 디지털 기술을 활용하여 임플란트를 식립 및 보철 수복한 증례이다. 구내 스캔 후 디지털 진단 왁스업을 토대로 임플란트 수술용 가이드를 제작한 뒤 임플란트 식립했다. 6개월의 충분한 골유착 후, 맞춤형 지대주와 첫번째 임시 보철물을 장착하였다. 2개월 후 지대주 수준에서 구강 스캔 및 디지털 안궁이전 장치로 가상 교합기 상마운팅하고 하악 운동을 기록했다. 하악의 움직임을 고려하여 두번째 임시 보철물을 제작, 장착 후 안정된 교합 상태에서 더블 스캔 과정으로 복제하여 지르코니아 최종 보철물을 디자인하고 장착했다.

Keywords

References

  1. Tahmaseb A, Wu V, Wismeijer D, Coucke W, Evans C. The accuracy of static computer-aided implant surgery: A systematic review and meta-analysis. Clin Oral Implants Res 2018;29:416-35.
  2. Pettersson A, Kero T, Gillot L, Cannas B, Faldt J, Soderberg R, Nasstrom K. Accuracy of CAD/CAM-guided surgical template implant surgery on human cadavers: Part I. J Prosthet Dent 2010;103:334-42. https://doi.org/10.1016/S0022-3913(10)60072-8
  3. Saleh WK, Ariffin E, Sherriff M, Bister D. Accuracy and reproducibility of linear measurements of resin, plaster, digital and printed study-models. J Orthod 2015;42:301-6. https://doi.org/10.1179/1465313315Y.0000000016
  4. Kapos T, Ashy LM, Gallucci GO, Weber HP, Wismeijer D. Computer-aided design and computer-assisted manufacturing in prosthetic implant dentistry. Int J Oral Maxillofac Implants 2009;24:110-7.
  5. Joda T, Bragger U. Digital vs. conventional implant prosthetic workflows: a cost/time analysis. Clin Oral Implants Res 2015;26:1430-5. https://doi.org/10.1111/clr.12476
  6. Lee J, Yoon M, Park T, Chun I, Yun K. The accuracy evaluation of digital surgical stents according to supported type. J Korean Acad Prosthodont 2018;56:8-16. https://doi.org/10.4047/jkap.2018.56.1.8
  7. Woodford SC, Robinson DL, Mehl A, Lee PVS, Ackland DC. Measurement of normal and pathological mandibular and temporomandibular joint kinematics: A systematic review. J Biomech 2020;111:109994. https://doi.org/10.1016/j.jbiomech.2020.109994
  8. Park C. Application of ARCUS digma I, II systems for full mouth reconstruction: a case report. J Dent Rehabil Appl Sci 2016;32:345-50. https://doi.org/10.14368/jdras.2016.32.4.345
  9. Zambrana N, Sesma N, Fomenko I, Dakir EI, Pieralli S. Jaw tracking integration to the virtual patient: A 4D dynamic approach. J Prosthet Dent 2022;S0022-3913(22)00110-X.[published online ahead of print, 2022 Mar 16]
  10. Lepidi L, Galli M, Mastrangelo F, Venezia P, Joda T, Wang HL, Li J. Virtual articulators and virtual mounting procedures: where do we stand? J Prosthodont 2021;30:24-35. https://doi.org/10.1111/jopr.13240
  11. Ury E, Fornai C, Weber GW. Accuracy of transferring analog dental casts to a virtual articulator. J Prosthet Dent 2020;123:305-13. https://doi.org/10.1016/j.prosdent.2018.12.019
  12. Pettersson A, Komiyama A, Hultin M, Nasstrom K, Klinge B. Accuracy of virtually planned and template guided implant surgery on edentate patients. Clin Implant Dent Relat Res 2012;14:527-37. https://doi.org/10.1111/j.1708-8208.2010.00285.x
  13. Sun Y, Luebbers HT, Agbaje JO, Schepers S, Politis C, Van Slycke S, Vrielinck L. Accuracy of dental implant placement using CBCT-derived mucosa-supported stereolithographic template. Clin Implant Dent Relat Res 2015;17:862-70. https://doi.org/10.1111/cid.12189
  14. Papaspyridakos P, Gallucci GO, Chen CJ, Hanssen S, Naert I, Vandenberghe B. Digital versus conventional implant impressions for edentulous patients: accuracy outcomes. Clin Oral Implants Res 2016;27:465-72.
  15. Imburgia M, Logozzo S, Hauschild U, Veronesi G, Mangano C, Mangano FG. Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study. BMC Oral Health 2017;17:92. https://doi.org/10.1186/s12903-017-0383-4
  16. Patzelt SB, Emmanouilidi A, Stampf S, Strub JR, Att W. Accuracy of full-arch scans using intraoral scanners. Clin Oral Investig 2014;18:1687-94. https://doi.org/10.1007/s00784-013-1132-y
  17. Serino G, Hultin K. Periimplant disease and prosthetic risk indicators: a literature review. Implant Dent 2019;28:125-37. https://doi.org/10.1097/ID.0000000000000841
  18. Celar AG, Tamaki K, Nitsche S, Schneider B. Guided versus unguided mandibular movement for duplicating intraoral eccentric tooth contacts in the articulator. J Prosthet Dent 1999;81:14-22. https://doi.org/10.1016/S0022-3913(99)70230-1