Study on Microstructure and Electrical Properties of Cement Mortar Containing Conductive Fibers

전도성 섬유가 함유된 시멘트 모르타르의 미세구조 및 전기적 특성 연구

  • 박종건 (건양대학교 공공안전연구소) ;
  • 서동주 (건양대학교 재난안전공학과) ;
  • 임두열 (건양대학교 재난안전공학과) ;
  • 이유재 (건양대학교 재난안전공학과) ;
  • 허광희 (건양대학교 해외건설플래트학과)
  • Received : 2022.03.28
  • Accepted : 2022.06.23
  • Published : 2022.06.30

Abstract

This paper studied the effect on the microstructure, electrical properties, and compressive strength of cement mortar containing carbon fiber (CF) and steel fiber (SF), which are conductive materials. The resistivity of conductive fiber-reinforced cement mortar (FRCM) was measured using the 4-probe method, and the compressive strength was measured based on the compression test. Their performance was compared and reviewed with plain mortar (PM). Furthermore, the surface shape and composition of the fracture surface of the conductive FRCM were analyzed using a scanning electron microscope (SEM) and an energy disperse X-ray spectrometer (EDS). The results showed that the resistivity gradually increased as the curing time increased in all specimens, whereas the resistivity decreased significantly as the fiber volume fraction increased. Adding steel fibers up to 1.25% did not affect the resistivity of cement mortar considerably. On the contrast, the resistivity of carbon fiber was somewhat decreased even at low contents (ie, 0.1 to 0.3%), and thereafter, it was significantly decreased. The percolation threshold of the conductive CFRCM containing CF used in this experiment was 0.4%, and it is judged to be the optimum carbon fiber dosage to maximize the conductive effect while maintaining the compressive strength performance as much as possible. For the surface shape and composition analysis of conductive FRCM, the fracture surface was observed through SEM-EDS. These results are considered to be very useful in establishing the microstructure mechanism of reinforcing fibers in cement mortars.

본 논문에서는 전도성 재료인 탄소섬유(carbon fiber, CF)와 강섬유(steel fiber, SF)를 함유한 시멘트 모르타르의 미세구조 및 전기적 특성, 압축강도에 미치는 영향을 연구하였다. 전도성 섬유보강 시멘트 모르타르(fiber-reinforced cement mortar, FRCM)의 비저항은 4-probe 방법을 이용하여 측정하였고, 압축강도는 압축시험을 기반으로 측정하였다. 이들의 성능은 플레인 모르타르(plain mortar, PM)와 비교, 검토하였다. 게다가 전도성 FRCM 파단면의 표면형상과 구성성분은 주사전자현미경(scanning electron microscope, SEM)과 에너지 분산형 X-ray 분광분석기(energy disperse X-ray spectrometer, EDS)를 이용하여 분석하였다. 그 결과 모든 시편에서 양생재령이 경과됨에 따라 비저항이 점차 증가하는 반면, 섬유혼입률이 증가할수록 비저항은 상당히 감소하였다. 강섬유를 1.25%까지 추가하여도 시멘트 모르타르의 비저항에는 크게 영향을 미치지 않았다. 대조적으로, 탄소섬유는 낮은 함량(즉, 0.1~0.3%)에서도 비저항이 다소 감소하였고, 그 이후에는 현저히 저하되었다. 본 실험에 사용된 CF가 함유된 전도성 CFRCM의 침투 임계점은 0.4%이었고, 압축강도 성능을 유지하면서 전도성 효과를 극대화하는 최적의 탄소섬유 혼입량이라고 판단된다. 전도성 FRCM의 표면형상 및 구성성분 분석을 위해 SEM/EDS를 통해 파단면을 관찰하였다. 이러한 결과는 시멘트 모르타르 내에서 보강섬유의 미세구조 메커니즘을 확립하는 데 매우 유용할 것으로 사료된다.

Keywords

Acknowledgement

이 논문은 2018년도 정부(교육부)의 재원으로 한국연구재단의 지원을 받아 수행된 기초연구사업입니다(Grant No. NRF-2018R1A6A1A03025542).

References

  1. ACI Committee 544. (2018), Guide to Design with Fiber-Reinforced Concrete(ACI 544.4R-18), Farmington Hills, MI 48331; American Concrete Institute (ACI).
  2. Belli, A., Mobili, A., Bellezze, T., and Tittarelli, F. (2020), Commercial and Recycled Carbon/Steel Fibers for Fiber-Reinforced Cement Mortars with High Electrical Conductivity. Cement and Concrete Composites, 109(2020), 103569. https://doi.org/10.1016/j.cemconcomp.2020.103569
  3. Brandt, A.M. (2008), Fibre Reinforced Cement-Based(FRC) Composites after over 40 Years of Development in Building and Civil Engineering. Composites Structures, 86, 3-9. https://doi.org/10.1016/j.compstruct.2008.03.006
  4. Lee, H.J., and Lim, H.J. (2018), Evaluation of Setting Delay in Mortar Adding Superplasticizer Using Electrical Resistivity Measurement. Journal of the Korea Institute for Structural Maintenance and Inspection, 22(6), 9-15. (in Korean) https://doi.org/10.11112/JKSMI.2018.22.6.009
  5. McCarter, W.J., Starrs, G., and Chrisp, T.M. (2000), Electrical Conductivity, Diffusion, and Permeability of Portland Cement-Based Mortars. Cement and Concrete Research, 30(9), 1395-1400. https://doi.org/10.1016/S0008-8846(00)00281-7
  6. Chiarello, M., and Zinno, R. (2005), Electrical Conductivity of Self-Monitoring CFRC. Cement and Concrete Composites, 27(4), 463-469. https://doi.org/10.1016/j.cemconcomp.2004.09.001
  7. Han, B., Ding, S.D., and Yu, X. (2015), Intrinsis Self-Sensing Concrete and Structures: A Review. Measurement, 59(2015), 110-128. https://doi.org/10.1016/j.measurement.2014.09.048
  8. Yildirim, G., Ozturk, O., Al-Dahawi, A., Ulu, A.A., and Sahmaran, M. (2020), Self-Sensing Capability of Engineered Cementitious Composites: Effects of Aging and Loading Conditions. Construction and Building Materials, 231(2020), 117132. https://doi.org/10.1016/j.conbuildmat.2019.117132
  9. Lim, Y.C. (2018), Experimental Study on the Effect of Specimen Size on Electrical Resistivity Measurement. Journal of the Korea Institute for Structural Maintenance and Inspection, 22(6), 164-169. (in Korean) https://doi.org/10.11112/JKSMI.2018.22.6.164
  10. Yoon, I.S. (2013), Influence of Micro-Structural Characteristics of Concrete on Electrical Resistivity. Journal of the Korea Institute for Structural Maintenance and Inspection, 17(6), 122-129. (in Korean) https://doi.org/10.11112/JKSMI.2013.17.6.122
  11. Kang. S.H. (1998), Electrically Conductive Concrete. Magazin of the Koea Concrete Institute, 10(6), 34-40.
  12. Chung, D.D.L. (2004), Electrically Conductive Cement-Based Materials. Advances in Cement Research, 16(4), 167-176. https://doi.org/10.1680/adcr.16.4.167.46658
  13. Han, B., Guan, X., and Ou, J. (2007), Electrode Design, Measuring Method and Data Acquisition System of Carbon Fiber Cement Paste Piezoresistive Sensors. Sensors and Actuators A: Physical, 135(2), 360-369. https://doi.org/10.1016/j.sna.2006.08.003
  14. Kang, M.S., Kang, M.S., Lee, H.J., Yim, H.J., and An, Y.K. (2018), Crack Initiation and Temperature Variation Effects on Self-Sensing Impedance Responses of FRCCs. Journal of the Korea Institute for Structural Maintenance and Inspection, 22(3), 69-74. (in Korean) https://doi.org/10.11112/JKSMI.2018.22.3.069
  15. Lee, N.K., Park, G.J., Park, J.J., and Kim, S.W. (2019), A Study on the Electrical Conductivity and Electromagnetic Shielding of High Performance Fiber Reinforced Cementitious Composites(HPFRCC). Journal of the Korea Institute for Structural Maintenance and Inspection, 23(2), 37-43. (in Korean)
  16. Xie, P.,. Gu, P., and Beaudoin, J.J. (1996), Electrical Percolation Phenomena in Cement Composites Containing Conductive Fibres, Journal of Materials Science, 31, 4093-4097. https://doi.org/10.1007/BF00352673
  17. KSL ISO 679. (2016), Methods of Testing Cements-Determination of Strength. Seoul, Korea: Korea Agency for Technology and Standards (KATS). (In Korean)
  18. EI-Enein, S.A., Kotkata, M.F., Hanna, G.B., Sadd, M., and EI Razek, M.M.A. (1995), Electrical Conductivity of Concrete Containing Silica Fume, Cement and Concrete Research, 25(8), 1615-1620. https://doi.org/10.1016/0008-8846(95)00156-5
  19. Wang, C., Jiao, G.S., Li, B.L., Peng, L., Feng, Y., Gao, N., and Li, K.Z. (2017), Dispersion of Carbon Fibers and Conductivity of Carbon Fiber-Reinforced Cement-Based Composites, Ceramics International, 43(17), 15122-15132. https://doi.org/10.1016/j.ceramint.2017.08.041
  20. Whittington, H., McCarter, J., and Forde, M. (1981), The Conduction of Electricity Through Concrete, Magazin of Concrete Research, 33, 48-60. https://doi.org/10.1680/macr.1981.33.114.48
  21. Dehghani, A., and Aslani, F. (2020), The Effect of Shape Memory Alloy, Steel, and Carbon Fibres on Fresh, Mechanical, and Electrical Properties of Self-Compacting Cementitious Composites, Cement and Concrete Composites, 112 (2020), 103659. https://doi.org/10.1016/j.cemconcomp.2020.103659
  22. Heo, G.H., Park, J.G., Song, K.C., Park, J.H., and Jun, H.M. (2020), Mechanical Properties of SiO2-Coated Carbon Fiber-Reinforced Mortar Composites with Different Fiber Length and Fiber Volume Fractions, Advances in Civil Engineering, (2020), 8881273.