DOI QR코드

DOI QR Code

Hysteretic Behavior of Diagonally Reinforced Concrete Coupling Beams According to Aspect Ratio and Volume Fraction of Steel Fiber Under Cyclic Loading

반복하중을 받는 대각보강된 철근콘크리트 연결보의 강섬유 형상비와 혼입률에 따른 이력거동

  • 최지윤 (한양대학교 건축공학과) ;
  • 손동희 (한양대학교 건축공학과) ;
  • 배백일 (한양사이버대학교, 디지털건축도시공학과) ;
  • 최창식 (한양대학교 건축공학부)
  • Received : 2022.04.07
  • Accepted : 2022.06.24
  • Published : 2022.06.30

Abstract

In this study, an experimental study was conducted to analyze the hysteresis behavior according to the steel fiber aspect ratio and volume fraction of diagonally reinforced concrete coupling beams under to cyclic loading. The aspect ratio and volume fraction of the steel fibers were set as the main variables, and 4 specimens were fabricated in which the amount of transverse reinforcement of the coupling beam suggested in the domestic building structural standard was relaxed by about 53%. In the experiment, cyclic loading experiments were performed in the displacement control method in accordance with ACI 374.2R-13, and as a result of the experiment, it was found that all specimens containing steel fibers exceeded the nominal shear strength suggested by the current structural standards. As the aspect ratio of the steel fibers increased, the steel fibers prevented the buckling of the diagonal reinforcement, and the bridging effect of the steel fibers held the crack surface of the concrete. The shear strength, stiffness reduction and energy dissipation capacity of the specimens containing steel fibers were superior to those of the Vf0 specimens without steel fibers. Therefore, it is judged that the steel fiber reinforced concrete can relieve the details of the transverse reinforced.

본 연구에서는 반복하중을 받는 대각선 철근콘크리트 커플링 보의 강섬유 형상비와 혼입률에 따른 이력거동을 분석하기 위한 실험적 연구를 수행하였다. 강섬유의 형상비와 혼입률을 주요변수로 설정하였으며, 국내 건축구조기준에서 제시한 연결보의 횡방향 보강량이 약 53% 완화된 4개의 실험체를 제작하였다. 실험에서는 ACI 374.2R-13에 따른 변위제어법으로 반복하중 실험을 수행하였으며, 실험 결과 강섬유가 혼입된 모든 실험체가 현행 구조기준에서 제시하는 공칭전단강도를 상회함을 확인하였다. 강섬유의 형상비가 증가할수록 대각선 철근의 좌굴을 방지하고 강섬유의 브리징 효과로 콘크리트의 균열면 증가를 방지하였다. 강섬유가 혼입된 실험체의 전단강도, 강성감소 및 에너지 소산능력은 강섬유가 혼입되지 않은 Vf0 실험체보다 우수하였다. 따라서 강섬유 철근콘크리트가 횡철근의 디테일을 완화할 수 있다고 판단된다.

Keywords

Acknowledgement

2022년도 정부(과학기술정보통신부)의 재원으로 한국연구 재단의 지원을 받아 수행된 연구임(No. NRF-2020R1A4A1019074).

References

  1. Korea Design Standard (2021). "Concrete seismic design standards", Korea construction standards center, KDS 14 20 80
  2. ACI 544.4R-88. (2017). Design considerations for steel fiber reinforced concrete, ACI Committee 544, American Concrete Institute, 18.
  3. ACI 374.2R-13. (2013). Guide for testing reinforced concrete structural elements under slowly applied simulated seismic load, ACI Committee 374, American Concrete Institute, 18.
  4. Paulay, T., and Binney, J.R. (1974), "Diagonally Reinforced Coupling Beams of Shear Walls", Shear in Reinforced Concrete, SP-42, American Concrete Institute, Farmington Hills, MI, Jan 1974, pp. 579-598.
  5. Naish, D., Fry, A., Klemencic, R., and Wallace, J. (2013). Reinforced concrete coupling beams-Part I: testing. ACI Structural Journal, 110(6), 1057.
  6. Fortney, P. J., Rassati, G. A., and Shahrooz, B. M. (2008). Investigation on effect of transverse reinforcement on performance of diagonally reinforced coupling beams. ACI Structural Journal, 105(6), 781.
  7. Oh, H. C., Lee, K.H., Han, S. W., Shin, M. S., and Jo. Y. W. (2015). Hysteretic Behavior Evaluation of a RC Coupling Beam using a Steel Fiber and Diagonal Reinforcement. Journal of the Korea Concrete Institute, 27(3), 288-295.
  8. Lee, H. H., Lee, H. J. (2004). Characteristic Strength and Deformation of SFRC Considering Steel Fiber Factor and Volume Fraction. Journal of the Korea Concrete Institute,16(6),759-766. https://doi.org/10.4334/JKCI.2004.16.6.759
  9. Kim, J. S., Bae, B. I., Choi, C. S.(2019). A Study on the Effect of Steel Fiber in Reinforced Concrete Coupling Beam Subjected to Cyclic Loading. JOURNAL OF THE ARCHITECTURAL INSTITUTE OF KOREA Structure & Construction, 35(10), 181-190.
  10. Park, W. S., Kang, T. H., Kim, S., & Yun, H. D. (2020). Seismic performance of moderately short concrete coupling beams with various reinforcements. ACI Structural Journal, 117(3), 141-152.
  11. Yazici, S., Inan, G., and Tabak, V. (2007). Effect of aspect ratio and volume fraction of steel fiber on the mechanical properties of SFRC. Construction and Building Materials, 21(6), 1250-1253. https://doi.org/10.1016/j.conbuildmat.2006.05.025
  12. Jang, S. J., Jeong, G. Y., & Yun, H. D. (2018). Use of steel fibers as transverse reinforcement in diagonally reinforced coupling beams with normal-and high-strength concrete. Construction and Building Materials, 187, 1020-1030. https://doi.org/10.1016/j.conbuildmat.2018.08.063
  13. Jang, S. J., Kang, D. H., Ahn, K. L., Park, W. S., Kim, S. W., and Yun, H. D. (2015). Feasibility of using high-performance steel fibre reinforced concrete for simplifying reinforcement details of critical members. International Journal of Polymer Science, 1-13
  14. Jang, S. J., Kim, S. W., Park, W. S., and Yun, H. D. (2013). Application of Steel Fiber Reinforced Concrete (SFRC) for Detail Simplification of Diagonally Reinforced Concrete Coupling Beam. Proceedings of the Korean Concrete Association Conference, 619-620.