DOI QR코드

DOI QR Code

A Study on MR Imaging Method for The Patient with Inserting Shoulder Joint Suture Anchor

견관절 삽입술을 시행한 환자의 자기 공명 영상법에 관한 연구

  • 박의철 (건양대학교 일반대학원 보건학과) ;
  • 배석환 (건양대학교 방사선학과) ;
  • 류연철 (가천대학교 방사선학과) ;
  • 박영준 (제주한라대학교 방사선과) ;
  • 김용권 (건양대학교 방사선학과)
  • Received : 2021.01.15
  • Accepted : 2021.04.02
  • Published : 2021.04.30

Abstract

Metallic suture anchors are very useful and common fixation devices that are inserted into the target bone to sustain the tendon of a patient with musculus supraspinatus tendon ruptures. On the other hand, the presence of a metallic material prosthesis, such as a metal suture anchor, causes severe MR imaging artifacts, including field distortion, signal loss, and failure of fat suppression. The difference in magnetic susceptibility between metal and other organic materials causes magnetic field distortion surrounding the prosthesis. The resulting magnetic field inhomogeneity makes the images with a lower signal-to-noise ratio and distortion. For a patient with a suture anchor implanted, MR imaging is the golden standard for determining the postoperative prognosis, and a fat-saturation sequence is one of the imaging methods most affected by metal-induced artifacts. In this study, three fat-saturation sequences were compared. Artifact quantification and contrast comparison between the supraspinatus tendon and the surrounding muscle were presented. The images obtained using the STIR pulse sequence showed fewer susceptibility artifacts and better visibility in the supraspinatus tendon and the tissue area. Therefore, the STIR sequence is the most appropriate fat-saturation imaging method for patients with a metallic prosthesis.

봉합 나사못을 이용한 견관절 수술 환자들의 예후를 확인하기 위하여 MRI(Magnetic Resonance Imaging)를 이용하여 추적검사를 시행한다. 봉합나사못을 삽입한 경우에는 임상적 관찰을 용이하게 하기 위하여 지방소거법을 이용한 영상촬영 기법이 이용되는데, 이때 이용되는 지방 신호 억제 기법으로 CHESS(Chemical Shift Selective), STIR(Short Tau Inversion Recovery), Dixon 기법 등이 주로 이용되고 있다. 봉합나사못은 비자성 재료를 이용해서 제작되지만, 환부에 삽입되는 티타늄 재질의 금속물질은 비자성체임에도 불구하고 국소자장을 왜곡시켜 결과 영상의 기하학적인 왜곡은 물론 심각한 영상신호의 감소 현상을 발생시킨다. 봉합나사못을 삽입하여 환부를 관찰하는 경우에는 뼈 혹은 뼈 인접 부위의 영상을 획득하여야 하는데 뼈와 주변 조직의 임상적 관찰을 위해서는 뼈의 지방 신호를 억제할 필요가 있다. 이때 이용되는 지방 신호 억제 기법은 금속 삽입물로 인한 자기장 불균일의 영향을 받는다. 본 연구에서는 3가지 지방억제 영상기법(CHESS, STIR, Dixon)을 이용하여 금속물질을 삽입한 환자로부터 영상을 획득하여 비교, 분석하였으며, 그 결과로 봉합나사못을 삽입한 환자의 병변 관찰 및 수술 후 예후를 관찰하기 위한 영상기법으로 STIR 영상기법이 가장 적합함을 알 수 있었다. 연구 결과에 따르면 금속 물질을 인체에 삽입한 환자의 경우, 지방 신호 억제가 필요한 MRI 검사에서는 STIR 기법을 이용하는 것이 임상적 가치가 높은 영상을 얻을 수 있을 것이다.

Keywords

References

  1. J. K. Yeom, H. J. Chung, H. J. Ra, "Arthroscopic Repair of Type II SLAP lesion with Bio-Knotless Anchor", Clinics in Shoulder and Elbow, Vol.10, No.1, pp.73-77, 2007. DOI : https://doi.org/10.5397/CiSE.2007.10.1.073
  2. O. Beuf, A. Bnquet, M. Lissac, R. Davis, "Magnetic resonance imaging for the determination of magnetic susceptibility of materials", Journal of Magnetic Resonance, Series B, Vol.1, No.2, pp.111-118, 1996. DOI : http://doi.org/10.1006/jmrb.1996.0120
  3. J. F. Schenck, "The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds", Medical Physics, Vol.23, pp.815-850, 1996. DOI : http://dx.doi.org/10.1118/1.597854
  4. F. K. Schaefer, P. J. Schaefer, J. Brossmann, C. Frahm, C. Muhle, R. E. Hilgert, et al., "Value of fat-suppressed PD-weighted TSE-sequences for detection of anterior and posterior cruciate ligament lesions-comparison to arthroscopy", Eur J Radiol, Vol.58, No.3, pp.411-415, 2006. DOI: https://doi.org/10.1016/j.ejrad.2005.12.034
  5. S. W. Atlas, R. I. Grossman, D. B. Hackney, "STIR MR imaging of the orbit", AJR, Vol.151, pp.1025-1030, 1988. DOI: https://doi.org/10.2214/ajr.151.5.1025
  6. R. Kluger, R. Mayrhofer, A. Kroner, et al., "Sonographic versus magnetic resonance arthrographic evaluation of full-thickness rotator cuff tears in millimeters", J Shoulder Elbow Surg., Vol.12, pp.110-116, 2005. DOI: https://doi.org/10.1067/mse.2003.10
  7. L. Favard, G. Bacle, J. Berhouet, "Rotator cuff repair", Joint Bone Spine, Vol.74, No.6, pp.551-557, 2007. DOI: https://doi.org/10.1016/j.jbspin.2007.08.003
  8. K. S. Kim, D. H. Ha, S. M. Lee, K. E. Yoo, J. H. Kim, "Efficiency of Contrast-Enhanced Fat-Suppressed Proton Density Images for Shoulder MRI: Comparison with Contrast-enhanced Fat-suppressed T1 Weighted Image and Arthroscopy", JKSR, Vol.60, pp.173-180, 2009. DOI : http://doi.org/10.3348/jksr.2009.60.3.173
  9. R. D. Singson, T. Hoang, S. Dan, M. Friedman, "MR evaluation of rotator cuff pathology using T2 Weighted fast spin-echo technique with and without fat-suppression", AJR, Vol.166, No.5, pp.1061-1065, 1996. DOI: http://doi.org/10.2214/ajr.166.5.8615243
  10. G. Krinsky, N. M. Rofsky, J. C. Weinreb, "Nonspecificity of short inversion time recovery(STIR) as a technique of fat suppression: pitfalls in image interpretation", AJR, Vol.166, No.3, pp.523-526, 1996. DOI: http://doi.org/10.2214/ajr.166.3.8623620
  11. A. Haase, J. Frahm, W. Hanicke, D. Matthaei, "1H NMR chemical shift selective(CHESS)imaging", Phys. Med. Biol., Vol.30, No.4, pp.341-344, 1985. DOI: http://doi.org/10.1088/0031-9155/30/4/008
  12. W. T. Dixon, "Simple proton spectroscopic imaging", Radiology, Vol.153, pp.189-194, 1984. DOI: http://doi.org/10.1148/radiology.153.1.6089263
  13. G. Glover, "Multipoint Dixon technique for water and fat proton and susceptibility imaging", J Magn Reson Imaging, Vol.1, pp.521-530, 1991. DOI: http://doi.org/10.1002/jmri.1880010504