References
- Ministry of Public Safety and Security, "National Fire Information Center E-Fire Statistics" (2019).
- A. C. Fernandez-Pello, H. K. Hasegawa, K. Staggs, A. E. Lipska-Quinn and N. J. Alvares, "A Study of the Fire Performance of Electrical Cables", Proceedings of the International Symposium, International Association for Fire Safety Science, pp. 237-247 (2006).
- NRC and EPRI, "Nuclear Power Plant Fire Modeling Analysis Guidelines", NUREG-1934 and EPRI 1023259, Finial Report (2012).
- NRC and EPRI, "Verification and Validation of Selected Fire Models for Nuclear Power Plant Application", NUREG-1824 and EPRI 1011999, Finial Report (2007).
- Y. Niu and W. Li, "Simulation Study on Value of Cable Fire in the Cable Tunnel", Journal of Procedia Engineering, Vol. 43, pp. 569-573 (2012). https://doi.org/10.1016/j.proeng.2012.08.100
- IEEE Power Engineering Society, "IEEE Standard for Qualifying Class 1E Electric Cables and Field Splices for Nuclear Power Generating stations", IEEE Std 383 (1974).
- IEEE Power Engineering Society, "IEEE Standard for Qualifying Class 1E Electric Cables and Field Splices for Nuclear Power Generating stations", IEEE Std 383 (2003).
- IEEE Power Engineering Society, "Standard for Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies", IEEE Std 1202 (1991).
- E. Braun, J. R. Shields and R. H. Harris, "Flammability Characteristics of Electrical Cables Using the Cone Calorimeter", NIST Rep. NISTIR 88 (1989).
- M. A. Barnes, P. J. Briggs, M. M. Hirschler, A. F. Matheson and T. J. O'Neill, "A Comparative Study of the Fire Performance of Halogenated and Non-halogenated Materials for Cable Applications. Part I Tests on Materials and Insulated Wires", Journal of Fire and Materials, Vol. 20, pp. 1-16 (1996). https://doi.org/10.1002/(SICI)1099-1018(199601)20:1<1::AID-FAM553>3.0.CO;2-W
- M. A. Barnes, P. J. Briggs, M. M. Hirschler, A. F. Matheson and T. J. O'Neill, "A Comparative Study of the Fire Performance of Halogenated and Non-halogenated Materials for Cable Applications. Part II Tests on Cable", Journal of Fire and Materials, Vol. 20, pp. 17-37 (1996). https://doi.org/10.1002/(SICI)1099-1018(199601)20:1<17::AID-FAM554>3.0.CO;2-C
- A. Matala and S. Hostikka, "Probabilistic Simulation of Cable Performance and Water Based Protection in Cable Tunnel Fires", Journal of Nuclear Engineering and Design, Vol. 241, pp. 5263-5274 (2011). https://doi.org/10.1016/j.nucengdes.2011.09.014
- R. Meinier, R. Sonnier, P. Zavaleta, S. Suard and L. Ferry, "Fire Behavior of Halogen-free Flame Retardant Electrical Cables with the Cone Calorimeter", Journal of Hazard Materials, Vol. 342, pp. 306-316 (2018). https://doi.org/10.1016/j.jhazmat.2017.08.027
- R. Sonnier, A. Viretto, A. Taguet and J.-M. Lopez-Cuesta, "Influence of the Morphology on the Fire Behavior of a Polycarbonate/poly(butylene terephthalate) Blend", Journal of Applied Polymer Science, Vol. 125, pp. 3148-3158 (2012). https://doi.org/10.1002/app.36480
- Q. Xie, H. Zhang and L. Tong, "Experimental Study on the Fire Protection Properties of PVC Sheath for Old and New Cables", Journal of Hazard Materials, Vol. 179, pp. 373-381 (2010). https://doi.org/10.1016/j.jhazmat.2010.03.015
- H. Yang, Q. Fu, X. Cheng, R. K. K. Yue and H. Zhang, "Investigation of the Flammability of Different Cables using Pyrolysis Combustion Flow Calorimeter", Journal of Procedia Engineering, Vol. 62, pp. 778-785 (2013). https://doi.org/10.1016/j.proeng.2013.08.125
- J. Luche, E. Mathis, T. Rogaume, F. Richard and E. Guillaume, "High-density Polyethylene Thermal Degradation and Gaseous Compound Evolution in a Cone Calorimeter", Journal of Fire Safety, Vol. 54, pp. 24-35 (2012). https://doi.org/10.1016/j.firesaf.2012.08.002
- ISO 5660-1, "Rate of Heat Release of Building Products (Cone Calorimeter)", International Standards Organization, Geneva, Switzerland (1992).
- P. J. DiNenno, D. Drysdale, C. L. Beyler, W. D. Walton, L. P. Richard, J. R. Hall and J. M. Watts, "SFPE Hand Book of Fire Protection Engineering (Third Edition)", National Fire Protection Association, Society of Fire Protection Engineers (2002).
- V. Babrauskas, "Development of the Cone Calorimeter. A bench-scale Heat Release Rate Apparatus based on Oxygen Consumption", Journal of Fire and Materials, Vol. 8, pp. 81-95 (1984). https://doi.org/10.1002/fam.810080206
- R. A. Bryant, T. J. Ohlemiller, E. L. Johnsson, A. Hamins, B. S. Grove, W. F. Gutherie, A. Maranghides and G. W. Mulholland, "The NIST 3MW Quantitative Heat Release Rate Facility-Description and Procedure", NISTIR-7052, (2004).
- K. K-Hoinghaus and J. B. Jeffries, "Applied Combustion Diagnostics", Combustion: An International Series, Taylor & Francis, New York (2002).
- G. W. Mulholland, "Smoke Production and Properties", SFPE Handbook of Fire Protection Engineering, 3rd Ed., Section 2, Chapter 13, NFPA, US (2002).