DOI QR코드

DOI QR Code

A Study on Operation Method of Protection Device for LVDC Distribution Feeder in Light Rail System

경전철용 LVDC 배전계통의 보호기기 운용 방안에 관한 연구

  • Kang, Min-Kwan (Department of Electrical Engineering, Korea University of Technology and Education) ;
  • Choi, Sung Sik (Department of Electrical Engineering, Korea University of Technology and Education) ;
  • Lee, Hu-Dong (Department of Electrical Engineering, Korea University of Technology and Education) ;
  • Kim, Gi-Yung (Department of Electrical Engineering, Korea University of Technology and Education) ;
  • Rho, Dae-Seok (Department of Electrical Engineering, Korea University of Technology and Education)
  • 강민관 (한국기술교육대학교 전기공학과) ;
  • 최성식 (한국기술교육대학교 전기공학과) ;
  • 이후동 (한국기술교육대학교 전기공학과) ;
  • 김기영 (한국기술교육대학교 전기공학과) ;
  • 노대석 (한국기술교육대학교 전기공학과)
  • Received : 2019.03.12
  • Accepted : 2019.04.05
  • Published : 2019.04.30

Abstract

Recently, when a fault occurs at a long-distance point in a LVDC (low voltage direct current) distribution feeder in a light rail system, the magnitude of the current can decrease to less than that of the load current of a light rail system. Therefore, proper protection coordination method to distinguish a fault current from a load current is required. To overcome these problems, this paper proposes an optimal algorithm of protection devices for a LVDC distribution feeder in a light rail system. In other words, based on the characteristics of the fault current for ground resistance and fault location, this paper proposes an optimal operation algorithm of a selective relay to properly identify the fault current compared to the load current in a light rail system. In addition, this paper modelled the distribution system including AC/DC converter using a PSCAD/EMTDC S/W and from the simulation results for a real light rail system, the proposed algorithm was found to be a useful and practical tool to correctly identify the fault current and load current.

최근, 출력전압의 제어가 가능하고 양방향 운용이 가능한 PWM(Pulse Width Modulation) 정류기가 도입되고 있다. 그러나, PWM 정류기가 적용될 경우, 전력계통측에서 사고발생하면, 회생전력에 의한 사고전류 공급으로 기존의 사고전류 크기 및 방향이 바뀔 가능성이 있다. 또한, 경전철용 급전시스템에서는 장거리 지점에서 사고가 발생하는 경우, 사고전류의 크기가 크게 감소되고, 부하전류와 비슷하거나 더 작은 경우가 발생할 수 있기 때문에 이에 대한 적절한 보호협조 운용 방안이 필요한 실정이다. 따라서, 본 논문에서는 상기의 문제점들을 해결하기 위하여, 경전철용 LVDC 배전선로의 보호기기 운용 방안을 제안한다. 구체적으로는 LVDC 배전선로에서의 거리 및 단락저항별 사고특성을 분석하여, 다양한 조건에서 사고를 적절하게 판별하는 직류선택계전기의 보호협조 운용방안을 제안한다. 또한, 배전계통 상용 해석 프로그램인 PSCAD/EMTDC를 이용하여 AC 계통, PWM 정류기, LVDC 배전선로로 구성된 경전철용 급전시스템의 모델링을 제시한다. 한편, 제안한 보호협조 알고리즘과 모델링을 이용하여 LVDC 배전선로의 보호기기 특성을 분석한 결과, 제안한 운용방식에서는 전류 경사각의 급격한 감소를 판정하는 보호요소를 추가한다. 따라서, 사고지점의 단락저항이 높거나 장거리 선로인 경우에도, 보호기기가 사고전류와 부하전류를 적절히 판별할 수 있어, 본 논문에서 제안한 보호협조 운용알고리즘의 유용성을 확인하였다.

Keywords

SHGSCZ_2019_v20n4_25_f0001.png 이미지

Fig. 1. Protection Coodination diagram in LVDC

SHGSCZ_2019_v20n4_25_f0002.png 이미지

Fig. 2. Concept of fault and load currents

SHGSCZ_2019_v20n4_25_f0003.png 이미지

Fig. 3. Operation plan of LVDC selection protection relay

SHGSCZ_2019_v20n4_25_f0004.png 이미지

Fig. 4. Operation algorithm of selection protection relay

SHGSCZ_2019_v20n4_25_f0005.png 이미지

Fig. 5. Modeling of power distributions

SHGSCZ_2019_v20n4_25_f0006.png 이미지

Fig. 6. Modeling of MW scaled PWM rectifier

SHGSCZ_2019_v20n4_25_f0007.png 이미지

Fig. 7. Entire modeling of power system

SHGSCZ_2019_v20n4_25_f0008.png 이미지

Fig. 8. Fault characteristics of ground resistance(0[Ω])

SHGSCZ_2019_v20n4_25_f0009.png 이미지

Fig. 9. Fault characteristics of ground resistance(3[Ω])

SHGSCZ_2019_v20n4_25_f0010.png 이미지

Fig. 10. Fault current characteristics of 5km distance

SHGSCZ_2019_v20n4_25_f0011.png 이미지

Fig. 11. Fault current characteristics of 8km distance

Table 1. Detailed parameters

SHGSCZ_2019_v20n4_25_t0001.png 이미지

Table 2. Simulation conditions of Protection relay

SHGSCZ_2019_v20n4_25_t0002.png 이미지

References

  1. Joorak Kim, Kijun Park, Chang-reung Park, Eun-Sang Choo, Jun-Young Lee, "Analysis on Voltage and Cost of Substation with PWM Rectifier in DC Traction Power Supply System" The Transactions of the KIEE, Vol. 64, No. 4, pp.640-645, 2015 DOI: http://dx.doi.org/10.5370/KIEE.2015.64.4.640
  2. Joorak Kim, Chang-reung Park, Kijun Park, Joo-Uk Kim, "A Study on DC Traction Power Supply System Using PWM Converter", J. Korean Inst. Electr. Electron. Mater. Eng Vol. 29, No. 4, pp.250-254, 2016. DOI: http://dx.doi.org/10.4313/JKEM.2016.29.4.250
  3. Sung-Yeol Kwon, Hyun-Chang Lee, Kyu-Tae Lee, "A Study on Performance Improvement of Detecting Current of the Norton Amplifier", The Journal of The Institute of Internet, Broadcasting and Communication, Vol. 18, No. 3, pp.185-191, 2018. DOI: https://doi.org/10.7236/JIIBC.2018.18.3.185
  4. Joorak Kim, "A Study on Power Flow Analysis of DC Traction Power Supply System with PWM Rectifier", The Transactions of the Korean Institute of Electrical Engineers Vol. 65, No. 11, pp.1919-1924, 2016. DOI: http://dx.doi.org/10.5370/KIEE.2016.65.11.1919
  5. Go-Woon Jeon, Hyeong-Jun Yoo, Jae-Sae Park, "Improving Regenerative Break Energy Efficiency and Voltage Regulation Capability of DC Electric Railway by Coordination of VSC and EDLC", The Transactions of the Korean Institute of Electrical Engineers, Vol. 64, No. 1, pp.176-181, 2015. DOI: http://doi.org/10.5370/KIEE.2015.64.1.176
  6. Kim Yong-Ki, Bae Chang-Han, Han Moon-Seob, Yang Young-Chul, Jang Su-jin, "Direction for Development of Energy Regeneration Device for DC Electric Railway System", Korean Society for Railway, pp.5, 2005.
  7. Joorak Kim, Moonseob Han, Yong-Ki Kim, Jung-Hoon Kim, "Development and Test of Inverter for Regenerative Power of DC Traction Power Supply System", Journal of the Korean Society for Railway. Vol. 12, No. 2, pp.254-259, 2009. DOI: http://uci.or.kr/G704-001404.2009.12.2.009
  8. Chang-Yong Lee, Jinho Kim, "The Prediction and Analysis of the Power Energy Time Series by Using the Elman Recurrent Neural Network", Journal of the Society of Korea Industrial and Systems Engineering, Vol. 41, No. 1, pp.84-93, 2018. DOI: https://doi.org/10.11627/jkise.2018.41.1.084
  9. Jae-Wan Yang, Young-Doo Lee, In-Soo Koo, "Sensor Fault Detection Scheme based on Deep Learning and Support Vector Machine", The Journal of The Institute of Internet, Broadcasting and Communication, Vol. 18, No. 2, pp.185-195, 2018. DOI: https://doi.org/10.7236/JIIBC.2018.18.2.185
  10. Min-Seop So, Hong-Bae Jun, Jong-Ho Shin, "Failure Analysis to Derive the Causes of Abnormal Condition of Electric Locomotive Subsystem", Journal of the Society of Korea Industrial and Systems Engineering, Vol. 41, No. 2, pp.84-94, 2018. DOI: https://doi.org/10.11627/jkise.2018.41.2.084
  11. Sung-Hee Park, Kee-Hong Um, "A Study on Development and Diagnosis Factors of On-Line DC Leakage Current System for Junctions of High-Voltage Cables in Operation at Thermoelectric Power Station", The Journal of The Institute of Internet, Broadcasting and Communication, Vol. 18, No. 6, pp.187-193, 2018. DOI: https://doi.org/10.7236/JIIBC.2018.18.6.187
  12. Byung-San Baek.Jae-Chul Kim, "A Study on the Development and Application of Digital Protective Relay for DC Feeding System of Light Rail Transit System", Journal of the Korean Institute of IIIuminating and Electrical Installation Engineers Vol. 19, No.2, pp.77-86, 2005. DOI: http://uci.or.kr/G704-000642.2005.19.2.016
  13. Yun-Sik Oh, Joon Han, Gi-Hyeon Gwon, Doo-Ung Kim, Chul-Ho Noh, Tack-Hyun Jung, Chul-Hwan Kim, "Analysis of Human Safety and System Effect according to Grounding Scheme in LVDC Distribution System", The Transactions of the Korean Institute of Electrical Engineers Vol. 63, No. 5, pp.608-614, 2014. DOI: http://dx.doi.org/10.5370/KIEE.2014.63.5.608
  14. Chan-Ki Kim, "A Study on the Algorithm Detecting DC Line Faults", HE The Transactions of the Korean Institute of Power Electronics, vol. 9, No. 5, pp.498-506, 2004. DOI: http://uci.or.kr/G704-000449.2004.9.5.012
  15. Sang-Gi Chung, Rag-Gyo Jeong, Hong-Sik Cho, Ahn-Ho Lee, Sam-Young Kwon, "Development of Ground Fault Protective Relaying Schemes for DC Traction Power Supply System", The Transactions of the Korean Institute of Electrical Engineers Vol. 54, No. 9, pp.427-433, 2005. DOI: http://uci.or.kr/G704-A00119.2005.54.9(A).002
  16. No-Geon Jung, Jae-Moon Kim, "An Experimental Study on Operation Setting Optimization of Circuit Breaker for Improving Safety on DC Railroad Feeder System", The Transactions of the Korean Institute of Electrical Engineers Vol. 65, No. 3, pp.526-531, 2016. DOI: http://uci.or.kr/G704-001404.2009.12.2.009 https://doi.org/10.5370/KIEE.2016.65.3.526