• Title/Summary/Keyword: PSCAD/EMTDC S/W

Search Result 38, Processing Time 0.032 seconds

Characteristic Analysis and Implementation of 30kW Portable Test Equipment for Performance Evaluation in Energy Storage System (30kW급 ESS용 이동형 성능평가 시험장치의 구현 및 특성분석)

  • Park, Jea-Bum;Kim, Mi-Sung;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.715-723
    • /
    • 2018
  • The energy storage system consists of batteries, power conditioning system and energy management system. If ESS is installed and operated in the field, SAT(Site Acceptance Test) of ESS is being essentially required for the safety and performance of ESS. Furthermore, in order to more accurately and reliably validate the performance of the ESS in advanced countries, it has been required to perform not only performance testing by H/W equipments but also performance verification by S/W tool. Therefore, this paper proposes the modeling of portable test equipment in order to evaluate the performance and reliability of ESS by using the PSCAD/EMTDC S/W. And also, the prototype of 30[kW] scaled portable test equipments is implemented based on the S/W modeling. From the results of various simulations and testings such as power quality, LVRT and anti-islanding tests, it is confirmed that 30[kW] scaled portable test equipment is useful for SAT of ESS, because the simulation results of PSCAD/EMTDC are identical to them of 30[kW] test equipment at the same test conditions.

The PV System Modeling Based on the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 태양광발전(PV) 모델링에 관한 연구)

  • Jeon, Jintaek;Rho, Daeseok;Kim, Chanhyeok;Wang, Yongpeel
    • Journal of the Korea Convergence Society
    • /
    • v.2 no.3
    • /
    • pp.15-23
    • /
    • 2011
  • This paper deals with the analysis for the operation characteristic of PV 3 phase inverter, considering the state equation through d-q coordinates transformation, and proposes an algorithm of controlling current using PI(Proportional Integral) controller to control the output and the theory algorithm of sinusoidal PWM method to design inverter. And also this paper performs PV modelling using PSCAD/EMTDC S/W which is commonly used in analysis of distribution system and confirms effectiveness of the modelling proposed in this paper by analyzing and comparing the EMTDC/PSCAD simulation result with the theoretical method.

Dynamic-state Model[1] Transmission Line Protective Relay Using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 송전선로 보호 계전기의 동특성 모델[1])

  • Lee, H.H.;Kim, C.H.;Cho, K.B.;Chang, B.T.;Lee, J.W.;Ahn, S.P.;Lee, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.348-350
    • /
    • 2003
  • In recent years, with the continuous development of modem power system, the need for high performance protection to meet the customers' requests for more stable and reliable power supply has become increasingly emphasized. So, there is urgent need for a proper testing platform about not only existing digital protection relay but also new digital protection relay on the transmission line. It is also dynamic-state test which can test the performance of digital relay. This paper suggests basic system model for testing transmission line protection using PSCAD/EMTDC, and presents the process of the component modeling in the basic system.

  • PDF

A Study on the Modeling Method of Performance Evaluation System for MW Scaled Energy Storage System Using the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 MW급 ESS용 성능평가설비 모델링 방안에 관한 연구)

  • Kang, Min-Kwan;Choi, Sung-Sik;Park, Jae-Beom;Nam, Yang-Hyeon;Kim, Eung-Sang;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.6
    • /
    • pp.885-891
    • /
    • 2017
  • The energy storage system(ESS) is a core component for exchanging the power system structure of the unidirectional power flow into a bidirectional structure. Its important role has been increasing because it has multiple functions such as output stabilization of new renewable energy, demand management, frequency regulation, etc. However, the performance evaluation technology of ESS in korea is lower than one of advanced countries and the recognition of standardization is also lack compared to advanced countries. Furthermore, in order to more accurately and reliably validate the performance of the ESS in advanced countries, it has been required to perform not only performance testing by H/W devices but also performance verification by S/W tool. Therefore, in order to verify the performance testing of ESS by S/W tool, this paper proposes the modeling method of performance testing devices for MW scaled ESS by using the PSCAD/EMTDC S/W, based on real testing devices in domestic institute. From the simulation results of proposed modeling method, it is confirmed that the proposed modeling method is a useful tool for performance validation of ESS.

Analysis and Design for Simulator of Test Devices of New Energy Sources Based on the PSCAD/EMTDC (PSCAD/EMTDC에 의한 분산전원용 계통연계 시뮬레이터의 설계 및 분석)

  • Son, Jun-Ho;Park, Hyen-Seok;Kim, Chang-Hyeok;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.842-845
    • /
    • 2009
  • 본 연구에서는 신 에너지전원(태양광)이 배전계통에 연계되어 운용되는 것을 상정하여, 정상상태와 비상(사고)상태, 전력품질(순시), 스마트배전설비 등에 대한 배전계통의 특성 및 신 에너지전원의 특성을 시험하고 분석할 수 있는 분산전원용 계통연계 시뮬레이터를 제작하고 평가하기 위하여, 배전계통 전용해석 S/W인 PSCAD/EMTDC를 이용하여 사전 시뮬레이션을 수행하여 설계를 수행하고, 시험결과를 분석하였다. 본 연구에서 제작한 시뮬레이터는 배전용변전소(154/22.9KV)의 주변압기와 3상 4선식 22.9KV 고압배전선로의 2개 선로 및 부하를 축약형태(약 1/100)로 모의한 것이지만, 주상변압기(13,200/380/220V) 이하의 저압 배전선로는 실계통과 거의 동일한 상태로 모의한 것이다. 이상의 구성요소 데이터를 산출하기 위하여 PSCAD/EMTDC를 이용하여 사전 시뮬레이션을 수행하여 설계 및 제작을 수행하고 그 효용성을 확인하였다.

  • PDF

A Vacuum Circuit Breaker Model for simulation of Transient Overvoltages Using the PSCAD/EMTDC (PSCAD/EMTDC를 이용한 과도전압 모의를 위한 진공차단기 모델 개발)

  • Lee, Wook-Hwa;Lee, J.H.;Lee, Jin;Choi, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.232-234
    • /
    • 2002
  • A Vacuum Circuit Breaker Model for simulation of transient overvoltages was developed by using the PSCAD/EMTDC. The Model includes the power frequency chopping current. Breaker withstand voltage, and quenching capability of High frequency currents. To verify the abilities of the breaker model, the simulation on the Lindmayer's single-phase circuit was carried out. The results show that using the proposed model, the transient overvoltages, current chopping, and multiple reignitions of vacuum breaker are properly reproduced as real phenomena. In further study, virtual chopping current will be incorporated into the model for 3 phase system.

  • PDF

Performance Evaluation for Test Devices of Distributed Generations Using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 분산전원 계통연계시험장치 성능평가)

  • Park, Hyeon-Seok;Son, Joon-Ho;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.89-92
    • /
    • 2011
  • 본 연구에서는 전력계통(특히 배전계통)의 해석분야에서 가장 일반적으로 사용되고 있는 상용 S/W인 PSCAD/EMTDC를 이용하여, 분산전원이 배전계통에 연계되어 운용되는 상태(정상, 사고, 품질상태)를 모의할 수 있는 계통연계 시험장치를 모델링하는 방법을 제시하였다. 이 모델링에 의한 다양한 시뮬레이션 결과를 바탕으로 분산전원 계통연계 시험장치의 기능을 확인하여, 분산전원이 연계된 배전 계통의 모의 시험장치를 제작하는데 기초적인 데이터로 활용할 수 있도록 하였다.

  • PDF

A Study on the Site Acceptance Test(SAT) Evaluation Algorithm of Energy Storage System using Li-ion Battery (리튬이온전지를 이용한 전기저장장치의 SAT용 성능평가 알고리즘에 관한 연구)

  • Park, Jea-Bum;Kim, Byung-Ki;Kim, Mi-Sung;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.26-37
    • /
    • 2019
  • Recently, standardization of installation progress and technology of site acceptance test(SAT) for energy storage system(ESS) are being required due to performance of ESS depending on working condition and environment even though the quality and safety of each component of ESS is guaranteed. And also, it has been required to perform not only performance testing by H/W equipments but also performance verification by S/W tool, in order to more accurately and reliably validate the performance of the ESS in advanced countries. Therefore, this paper proposes evaluation algorithm for SAT to evaluate performance of ESS and presents modeling of SAT test equipment for ESS by using PSCAD/EMTDC. Furthermore, 30[kW] scaled portable test equipments is implemented based on the proposed algorithm and modeling. From the various simulation and test results, it is confirmed that performance of ESS related to characteristics of capacity and Round-trip efficiency, Duty-cycle efficiency, low voltage ride through(LVRT) and Anti-islanding can be accurately evaluated and that the simulation results of PSCAD/EMTDC are identical to test results of 30[kW] test equipment.

Analysis of the Harmonic Resonance of Primary Restorative Transmission System Using PSCAD/EMTDC PART II (PSCADI/EMTDC를 이용한 시송전계통의 고조파 공진현상 분석 II)

  • Lee H. J.;Yoo W. K.;Lee K. S.;Park S. M.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.48-50
    • /
    • 2004
  • The energization of high voltage transmission lines and transformers, that is an inevitable process in most countries as the first restorative action for wide-area blackout, may induce overvoltages such as sustained overvoltage, transient overvoltage and harmonic resonant overvoltage. And these may cause damages to power system equipments or failure of surge arresters. The harmonic resonant overvoltage originates in switching operations and nonlinear characteristics of equipments. Actually it is difficult to predict the occurrence of harmonic overvoltage, since they result from nonlinear characteristics of transformers and other equipments. This paper describes the analysis of domestic primary restorative transmission system using PSCAD/EMTDC. The harmonic resonance is verified and the solution to prevent harmonic resonance is proposed in this paper. As a result, the PSCAD/EMTBC simulation showed slightly conflictive results that had been presented by IEEE Power System Restoration Working Group report.

  • PDF

The Development of Transient Analysis Model and Performace Analysis of 345[kV] 100[MVA] STATCOM (345[kV] 100[MVA] STATCOM 과도해석 모델 개발 및 동특성 분석)

  • Yoon, Jong-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.28-34
    • /
    • 2011
  • This paper describes the development of the transient analysis model of 345[kV] 100[MVA] STATCOM and the result of the performance analysis. The Korea power utility company, KEPCO began a commercial operation of a 100[MVA] STATCOM(Static synchronous COMpensator) at 345[kV] Migeum substation in Seoul. In order to operate a new control device like STATCOM to the power system, suitable transient model is needed. Therfore, Korea Electric Power Coporation(KEPCO) developed a transient analysis models using EMTDC/PSCAD. The development of this transient analysis model is based on the actual STATCOM S/W algorithm and H/W specification that was provided by its manufacture. Through this model, the transient/dynamic performance of STATCOM at Migeum substation can be analyzed.