Fig. 1 Schematic diagram of the Unit-type GHX
Fig. 2 Mechanism of the groundsurface heat flux12)
Fig. 3 Numerical model of unit-type GHX
Fig. 4 Underground temperature at depth 1 m and 5 m
Fig. 5 Daily average HER according to change of EWT
Fig. 6 Performance of uni-type GHX according to local climate
Table 1 Simulation conditions
Table 2 Case study condition and average annual outdoor/ground surface temperature
References
- Oh, J. h., Seo, J. H., and Nam, Y. J., Performance Analysis of a Low-depth Unit-type Ground Heat Exchanger using Numerical Simulation, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 27, No. 3, pp. 169-173, 2015. https://doi.org/10.6110/KJACR.2015.27.3.169
- Kim, M. J., Lee, S. R., Yoon, S., and Jeon, J. S., Suggestions of Design Method for a Horizontal Straight Ground Heat Exchanger, Transactions of the Korea society of Geothermal Energy Engineers, Vol. 12, No. 4, pp. 1-7, 2016. https://doi.org/10.17664/KSGEE.2016.12.4.001
- Sohn, B. H., Effect of Soil Thermal Conductivity and Moisture Content on Design Length of Horizontal Ground Heat Exchanger, Transactions of Korea society of Geothermal Energy Engineers, Vol. 8, No. 1, pp. 21-31, 2012.
- Pu, L., Xu, L., Qi, D., and Li, Y., Structure Optimization for Horizontal Ground Heat Exchanger, Applied Thermal Engineering, Vol. 136, pp. 131-140, 2018. https://doi.org/10.1016/j.applthermaleng.2018.02.101
- Sohn, B., Performance Analysis of Ground-Coupled Heat Pump System with Slinky-Type Horizontal Ground Heat Exchanger, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 24, No. 3, pp. 230-239, 2012. https://doi.org/10.6110/KJACR.2012.24.3.230
- Yoon, S. and Lee, S., Analysis of Construction Cost and Influence Factors on Horizontal Ground Heat Exchangers, New & Renewable Energy, Vol. 10, No. 3, pp. 6-13, 2014. https://doi.org/10.7849/ksnre.2014.10.3.006
- Naili, N., Hazami, M., Attar, I., and Farhat, A., In-field Performance Analysis of Ground Source Cooling System with Horizontal Ground Heat Exchanger in Tunisia, Energy, Vol. 61, pp. 319-331, 2013. https://doi.org/10.1016/j.energy.2013.08.054
- Oh, J. H. and Nam, Y., The Performance Analysis for Low-depth Unit-type Ground Heat Exchanger according to Grouting Materials, Transactions of the Korea Society of Geothermal Energy Engineers, Vol. 11, No. 2, pp. 7-11, 2015. https://doi.org/10.17664/KSGEE.2015.11.2.007
- Kim, J. M., Bae, S., and Nam, Y. J., Performance and Feasibility Analysis on the Unit-Type Ground Heat Exchanger under a Building, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 30, No. 5, pp. 228-236, 2018. https://doi.org/10.6110/KJACR.2018.30.5.228
- Bae, S., Kim, H., Jeon, J. Y., and Nam, Y., Sensitivity Analysis of the Design Factor for Vertical Closed-loop Geothermal System using Numerical Analysis -Focused on Heating Operation-, KIEAE Journal, Vol. 18, No. 5, pp. 55-61, 2018. https://doi.org/10.12813/kieae.2018.18.5.055
- Bae, S., Feasibility analysis and Performance Prediction of Ground Source Heat Pump System using Deep Ground Heat Exchanger, Master Thesis, Pusan National University, Korea, 2017.
- Nam, Y., Ooka, R., and Hwang, S., Development of a Numerical Model to Predict Heat Exchange Rates for Ground-source Heat Pump System, Energy and Buildings, Vol. 40, pp. 2133-2140, 2008. https://doi.org/10.1016/j.enbuild.2008.06.004