Abstract

The overhead contact line (OCL) is a key piece of equipment for transmitting electrical energy to the pantograph of rail cars. Recently, a 400 km/h OCL was applied to the Honam high-speed line, and its performance was examined by running HEMU-430X. For the study, we analyzed the current of catenary wire concurrently while running HEMU-430X in the Honam high-speed line. Specifically, this study recorded the currents for each speed during operation of the railway vehicle. The analysis of the frequency of line current showed generation of third-harmonics, 15th-harmonics, 17th-harmonics, and 19th-harmonics. The current of catenary wire is a basic technology assessment used to determine the electrical safety of electric railway systems, and it can be used as a technology for analyzing circulating currents generated in the current configuration, as well as for analyzing electric fatigue of the OCL components.

Keywords

JJJRCC_2019_v32n1_1_f0001.png 이미지

Fig. 1. Picture of current monitoring system, (a) installation of current monitoring system on OCL (overhead contact line) in Honam high-speed line and (b) program for analysis of current.

JJJRCC_2019_v32n1_1_f0002.png 이미지

Fig. 2. Infrastructure gauge of Honam high-speed line from Iksan to Jungub.

JJJRCC_2019_v32n1_1_f0003.png 이미지

Fig. 3. Results of current wave from between contact and catenary wire of HEMU-430X on Honam HSR, (a) 159 km/h, (b) 290 km/h, (c) 349 km/h, and (d) 370 km/h.

JJJRCC_2019_v32n1_1_f0004.png 이미지

Fig. 4. Results of current analysis of catenary system on Honam HSR line, (a) current wave and (b) frequency analysis.

Table. 1. Physical properties of overhead contact wire and catenary wire.

JJJRCC_2019_v32n1_1_t0001.png 이미지

References

  1. Y. S. Park, K. M. Na, and Y. Park, Trans. Korean. Inst. Elect. Eng., 67, 976 (2018). [DOI: https://doi.org/10.5370/KIEE.2018.67.7.976]
  2. Y. Park, K. Lee, S. Y. Park, J. Y. Park, and W. S. Choi, Trans. Korean. Inst. Elect. Eng., 64, 1406 (2015). [DOI: https://doi.org/10.5370/KIEE.2015.64.9.1406]
  3. Y. H. Cho, K. Lee, S. Y. Kwon, and H. R. Cho, Trans. Korean. Inst. Elect. Eng., 64, 1789 (2015). [DOI: https://doi.org/10.5370/KIEE.2015.64.12.1789]
  4. Y. Park, S. K. Shin, K. Lee, J. Kim, and W. Kim, Trans. Korean. Inst. Elect. Eng., 62, 573 (2013). [DOI: https://doi.org/10.5370/KIEE.2013.62.4.573]
  5. Y. Park, Y. H. Cho, K. W. Lee, H. J. Kim, and I. C. Kim, J. Korean Inst. Electr. Electron. Mater. Eng., 22, 864 (2009). [DOI: https://doi.org/10.4313/JKEM.2009.22.10.864]
  6. J. H. Kim, J. G. Lee, K. S. Lee, W. Rhee, and H. B. Lee, Trans. Korean. Inst. Elect. Eng., 62, 6 (2013). [DOI: https://doi.org/10.5370/KIEEP.2013.62.1.006]
  7. Y. Park, H. Jung, and K. Lee, Trans. Korean. Inst. Elect. Eng., 62, 1465 (2013). [DOI: https://doi.org/10.5370/KIEE.2013.62.10.1465]