DOI QR코드

DOI QR Code

Cyberknife Dosimetric Planning Using a Dose-Limiting Shell Method for Brain Metastases

  • Yoon, Kyoung Jun (Radiosurgery Center, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Cho, Byungchul (Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Kwak, Jung Won (Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Lee, Doheui (Radiosurgery Center, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Kwon, Do Hoon (Department of Neurosurgery, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Ahn, Seung Do (Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Lee, Sang-Wook (Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Kim, Chang Jin (Department of Neurosurgery, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Roh, Sung Woo (Department of Neurosurgery, Asan Medical Center, University of Ulsan College of Medicine) ;
  • Cho, Young Hyun (Department of Neurosurgery, Asan Medical Center, University of Ulsan College of Medicine)
  • 투고 : 2018.04.02
  • 심사 : 2018.08.04
  • 발행 : 2018.11.01

초록

Objective : We investigated the effect of optimization in dose-limiting shell method on the dosimetric quality of CyberKnife (CK) plans in treating brain metastases (BMs). Methods : We selected 19 BMs previously treated using CK between 2014 and 2015. The original CK plans ($CK_{original}$) had been produced using 1 to 3 dose-limiting shells : one at the prescription isodose level (PIDL) for dose conformity and the others at low-isodose levels (10-30% of prescription dose) for dose spillage. In each case, a modified CK plan ($CK_{modified}$) was generated using 5 dose-limiting shells : one at the PIDL, another at intermediate isodose level (50% of prescription dose) for steeper dose fall-off, and the others at low-isodose levels, with an optimized shell-dilation size based on our experience. A Gamma Knife (GK) plan was also produced using the original contour set. Thus, three data sets of dosimetric parameters were generated and compared. Results : There were no differences in the conformity indices among the $CK_{original}$, $CK_{modified}$, and GK plans (mean 1.22, 1.18, and 1.24, respectively; p=0.079) and tumor coverage (mean 99.5%, 99.5%, and 99.4%, respectively; p=0.177), whereas the $CK_{modified}$ plans produced significantly smaller normal tissue volumes receiving 50% of prescription dose than those produced by the $CK_{original}$ plans (p<0.001), with no statistical differences in those volumes compared with GK plans (p=0.345). Conclusion : These results indicate that significantly steeper dose fall-off is able to be achieved in the CK system by optimizing the shell function while maintaining high conformity of dose to tumor.

키워드

참고문헌

  1. Blonigen BJ, Steinmetz RD, Levin L, Lamba MA, Warnick RE, Breneman JC : Irradiated volume as a predictor of brain radionecrosis after linear accelerator stereotactic radiosurgery. Int J Radiat Oncol Biol Phys 77 : 996-1001, 2010 https://doi.org/10.1016/j.ijrobp.2009.06.006
  2. Chin LS, Ma L, DiBiase S : Radiation necrosis following gamma knife surgery: a case-controlled comparison of treatment parameters and longterm clinical follow up. J Neurosurg 94 : 899-904, 2001 https://doi.org/10.3171/jns.2001.94.6.0899
  3. Cho YH, Lee JM, Lee D, Park JH, Yoon K, Kim SO, et al. : Experiences on two different stereotactic radiosurgery modalities of Gamma Knife and Cyberknife in treating brain metastases. Acta neurochir (Wien) 157 : 2003-2009; discussion 2009, 2015 https://doi.org/10.1007/s00701-015-2585-3
  4. Fahrig A, Ganslandt O, Lambrecht U, Grabenbauer G, Kleinert G, Sauer R, et al. : Hypofractionated stereotactic radiotherapy for brain metastases--results from three different dose concepts. Strahlenther Onkol 183 : 625-630, 2007 https://doi.org/10.1007/s00066-007-1714-1
  5. Feuvret L, Vinchon S, Martin V, Lamproglou I, Halley A, Calugaru V, et al. : Stereotactic radiotherapy for large solitary brain metastases. Cancer Radiother 18 : 97-106, 2014 https://doi.org/10.1016/j.canrad.2013.12.003
  6. Gevaert T, Levivier M, Lacornerie T, Verellen D, Engels B, Reynaert N, et al. : Dosimetric comparison of different treatment modalities for stereotactic radiosurgery of arteriovenous malformations and acoustic neuromas. Radiother Oncol 106 : 192-197, 2013 https://doi.org/10.1016/j.radonc.2012.07.002
  7. Giubilei C, Ingrosso G, D'Andrea M, Benassi M, Santoni R : Hypofractionated stereotactic radiotherapy in combination with whole brain radiotherapy for brain metastases. J Neurooncol 91 : 207-212, 2009 https://doi.org/10.1007/s11060-008-9700-8
  8. Jiang XS, Xiao JP, Zhang Y, Xu YJ, Li XP, Chen XJ, et al. : Hypofractionated stereotactic radiotherapy for brain metastases larger than three centimeters. Radiat Oncol 7 : 36, 2012 https://doi.org/10.1186/1748-717X-7-36
  9. Kaul D, Badakhshi H, Gevaert T, Pasemann D, Budach V, Tuleasca C, et al. : Dosimetric comparison of different treatment modalities for stereotactic radiosurgery of meningioma. Acta Neurochir (Wien) 157 : 559-563; discussion 563-564, 2015 https://doi.org/10.1007/s00701-014-2272-9
  10. Kim YJ, Cho KH, Kim JY, Lim YK, Min HS, Lee SH, et al. : Single-dose versus fractionated stereotactic radiotherapy for brain metastases. Int J Radiat Oncol Biol Phys 81 : 483-489, 2011 https://doi.org/10.1016/j.ijrobp.2010.05.033
  11. Korytko T, Radivoyevitch T, Colussi V, Wessels BW, Pillai K, Maciunas RJ, et al. : 12 Gy gamma knife radiosurgical volume is a predictor for radiation necrosis in non-AVM intracranial tumors. Int J Radiat Oncol Biol Phys 64 : 419-424, 2006 https://doi.org/10.1016/j.ijrobp.2005.07.980
  12. Kwon AK, Dibiase SJ, Wang B, Hughes SL, Milcarek B, Zhu Y : Hypofractionated stereotactic radiotherapy for the treatment of brain metastases. Cancer 115 : 890-898, 2009 https://doi.org/10.1002/cncr.24082
  13. Ma L, Sahgal A, Descovich M, Cho YB, Chuang C, Huang K, et al. : Equivalence in dose fall-off for isocentric and nonisocentric intracranial treatment modalities and its impact on dose fractionation schemes. Int J Radiat Oncol Biol Phys 76 : 943-948, 2010 https://doi.org/10.1016/j.ijrobp.2009.07.1721
  14. Massager N, Maris C, Nissim O, Devriendt D, Salmon I, Levivier M : Experimental analysis of radiation dose distribution in radiosurgery. II. Dose fall-off outside the target volume. Stereotact Funct Neurosurg 87 : 137-142, 2009 https://doi.org/10.1159/000209293
  15. Meeks SL, Buatti JM, Bova FJ, Friedman WA, Mendenhall WM : Treatment planning optimization for linear accelerator radiosurgery. Int J Radiat Oncol Biol Phys 41 : 183-197, 1998 https://doi.org/10.1016/S0360-3016(98)00044-3
  16. Minniti G, Clarke E, Lanzetta G, Osti MF, Trasimeni G, Bozzao A, et al. : Stereotactic radiosurgery for brain metastases: analysis of outcome and risk of brain radionecrosis. Radiat Oncol 6 : 48, 2011 https://doi.org/10.1186/1748-717X-6-48
  17. Minniti G, D'Angelillo RM, Scaringi C, Trodella LE, Clarke E, Matteucci P, et al. : Fractionated stereotactic radiosurgery for patients with brain metastases. J Neurooncol 117 : 295-301, 2014 https://doi.org/10.1007/s11060-014-1388-3
  18. Murai T, Ogino H, Manabe Y, Iwabuchi M, Okumura T, Matsushita Y, et al. : Fractionated stereotactic radiotherapy using CyberKnife for the treatment of large brain metastases: a dose escalation study. Clin Oncol (R Coll Radiol) 26 : 151-158, 2014 https://doi.org/10.1016/j.clon.2013.11.027
  19. Paddick I, Lippitz B : A simple dose gradient measurement tool to complement the conformity index. J Neurosurg 105 Suppl : 194-201, 2006 https://doi.org/10.3171/sup.2006.105.7.194
  20. Sio TT, Jang S, Lee SW, Curran B, Pyakuryal AP, Sternick ES : Comparing Gamma Knife and CyberKnife in patients with brain metastases. J Appl Clin Med Phys 15 : 4095, 2014
  21. Solberg TD, Balter JM, Benedict SH, Fraass BA, Kavanagh B, Miyamoto C, et al. : Quality and safety considerations in stereotactic radiosurgery and stereotactic body radiation therapy: executive summary. Pract Radiat Oncol 2 : 2-9, 2012 https://doi.org/10.1016/j.prro.2011.06.014
  22. Wagner TH, Bova FJ, Friedman WA, Buatti JM, Bouchet LG, Meeks SL : A simple and reliable index for scoring rival stereotactic radiosurgery plans. Int J Radiat Oncol Biol Phys 57 : 1141-1149, 2003 https://doi.org/10.1016/S0360-3016(03)01563-3
  23. Wowra B, Muacevic A, Tonn JC : Quality of radiosurgery for single brain metastases with respect to treatment technology: a matched-pair analysis. J Neurooncol 94 : 69-77, 2009 https://doi.org/10.1007/s11060-009-9802-y
  24. Yu C, Jozsef G, Apuzzo ML, Petrovich Z : Dosimetric comparison of CyberKnife with other radiosurgical modalities for an ellipsoidal target. Neurosurgery 53 : 1155-1162; discussion 1162-1163, 2003 https://doi.org/10.1227/01.NEU.0000088805.01793.5A
  25. Zeverino M, Jaccard M, Patin D, Ryckx N, Marguet M, Tuleasca C, et al. : Commissioning of the leksell Gamma Knife(R) $Icon^{TM}$. Med Phys 44 : 355-363, 2017 https://doi.org/10.1002/mp.12052