DOI QR코드

DOI QR Code

Comparison of Tangential and Axial Flow Cyclones for Small Dust Collectors

소형 집진기용 접선식 및 축류식 사이클론 성능비교

  • Lee, Sungwon (School of Mechanical Engineering, Daegu University) ;
  • Lee, Chungmin (School of Mechanical Engineering, Daegu University) ;
  • Yoon, Jong-Hwan (School of Mechanical Engineering, Daegu University)
  • Received : 2018.07.31
  • Accepted : 2018.08.29
  • Published : 2018.08.31

Abstract

The tangential and axial cyclones were fabricated using a 3D printer and the total collecting efficiency, cut-diameter, and pressure drop characteristics of the two types of cyclones with the same inlet area were investigated experimentally. The results show that the total collecting efficiency tends to increase as the inlet velocity increases. However, at a 20m/s condition of the tangential cyclone, the collected particles were re-entrained to the ascending vortex flow, resulting in a decrease of the total collecting efficiency. In the axial cyclone, the cross-sectional area is designed to increase at the inlet and the velocity is reduced, so that the re-entrainment effect does not appear in this study. The pressure loss of the tangential cyclone was larger than that of the axial cyclone. The cut-diameter tends to decrease with increasing the inlet velocity in two types of cyclones, except for the 20m/s condition of the tangential cyclone.

Keywords

References

  1. Shapiro, M. and Galperin, V., 2005, "Air Classification of Solid Particles: a Review," Chem. Eng. and Process., Vol. 44, pp. 279-285. https://doi.org/10.1016/j.cep.2004.02.022
  2. Malvern Instruments Worldwide, 2012, A Basic Guide to Particle Characterization, Malvern Instruments Limited, Worcestershire, pp. 1-26.
  3. Cooper, C. D. and Alley, F. C., 2011, Air Pollution Control: A Design Approach, Waveland Press, Long Grove, pp. 135-159.
  4. Lee, C. and Lee, C., 2011, "Comparisons of Dust Collection Efficiency on the Tangental Entry and Axial-vane Type Cyclone," Journal of the Korean Society of Manufacturing Process Engineers, Vol. 10, No. 6, pp. 115-121.
  5. Lee, C. and Lee. C., 2012, "A Numerical Analysis on Prediction of Cut-diameter according to Vane Outflow Angle in the Axial-flow Cyclone," Journal of the Korean Society of Manufacturing Process Engineers, Vol. 11, No. 4, pp. 111-117.
  6. http://www.heumannenviro.com
  7. Ogawa, A., 1984, "Re-entrainment of Dusts from the Dust Layer on the Deposited Dusts in the Cyclone Dust Collectors," Particulate Science and technology, Vol. 2, No. 4, pp. 305-314. https://doi.org/10.1080/02726358408906414
  8. Zuo, Z. and Chen, Q., 2015, "The Structure Optimization Design of Anti Re-entrainment Cone in Cyclone Separator," International Conference on Industrial Electronics and Applications, pp. 491-494.