Effect of Dry Fog Injection on Waste Decomposition in an Aerobic Landfill

호기성매립지에서 드라이포그 주입에 의한 폐기물분해 촉진에 관한 연구

  • Received : 2018.04.09
  • Accepted : 2018.06.07
  • Published : 2018.06.30

Abstract

The objective of this research was to assess the effect of moisture content and water injection method into the landfill on waste decomposition in an aerobic landfill. Firstly, respirometric experiments were performed in order to assess the effect of initial moisture content (20%, 30%, 40% and 50% respectively) on landfilled waste decomposition. The cumulative oxygen uptake and oxygen uptake rate were highly increased with the increase of initial moisture content. Secondly, lysimeter experiments showed that in comparison with the vertical injection method, dry fog system enhanced decomposition of organic wastes. Also, dry fog system provided uniform moisture distribution more than the vertical injection method within landfill.

본 연구의 목적은 호기성 매립지에서 함수율 및 수분주입 방법이 폐기물 분해에 미치는 영향을 평가하는데 있다. 초기 함수율(20%, 30%, 40% 및 50%)이 매립 폐기물 분해에 미치는 영향을 평가하기 위해 호흡율 실험을 수행하였다. 그 결과 누적 산소소모량과 산소 소모율은 초기 함수율에 의해 크게 영향을 받는 것으로 나타났으며, 초기 함수율이 증가할수록 증가하였다. 둘째, 매립지 내부 수분주입 방법으로서 드라이포그 시스템의 효율을 평가하기 위해 모의매립 실험을 수행하였다. 실험 결과 수분의 수직 주입방법과 비교하여 드라이포그 시스템이 유기성 폐기물의 분해를 촉진함을 보여 주었다. 또한 드라이포그 시스템은 수직 주입방식보다 매립지 내부에서 더욱 균일한 수분 분포를 나타내었다.

Keywords

References

  1. Heyer, K.-U., Hupe, K., Ritzkowski, M. and Stegmann, R., "Pollutant Release and Pollutant Reduction - Impact of the Aeration of Landfills", Waste Management, 25(4), pp. 353-359. (2005). https://doi.org/10.1016/j.wasman.2005.02.007
  2. Lee, N., Kusuda, T., Shimaoka, T., Matsufuji, Y. and Hanashima, M., "Pollutant Transformations in Landfill Layers", Waste Management and Research, 12(1), pp. 33-48. (1994). https://doi.org/10.1177/0734242X9401200105
  3. Prantl, R., Tesar, M., Huber-Humer, M. and Lechner, P., "Changes in Carbon and Nitrogen Pool during In-situ Aeration of Old Landfills under Varying Conditions", Waste Management, 26(4), pp. 373-380. (2006). https://doi.org/10.1016/j.wasman.2005.11.010
  4. Rich, C., Gronow, J. and Voulvoulis, N., "The Potential for Aeration of MSW Landfills to Accelerate Completion", Waste Management, 28(6), pp. 1039-1048. (2008). https://doi.org/10.1016/j.wasman.2007.03.022
  5. Lee, N. H., "Improvement of Post-care System for Solid Waste Landfills", Korea Environment Resources Corporation, pp. 98-103 (2008).
  6. Ritzkowski, M., Heyer, K.-U. and Stegmann, R., "Fundamental Processes and Implications during In Situ Aeration of Old Landfills", Waste Management, 26(4), pp. 356-372. (2006). https://doi.org/10.1016/j.wasman.2005.11.009
  7. Ritzkowski, M. and Stegmann, R., "Generating $CO_2$-credits through Landfill In Situ Aeration", Waste Management, 30(4), pp. 702-706. (2010) https://doi.org/10.1016/j.wasman.2009.11.014
  8. Park, J. K., Lee, N. H. and Yoon, S. P., "Change in Biodegradability of Landfilled Waste by Field-Scale Aerobic Landfill Stabilization", Journal of Korea Society of Waste Management, 28(3), pp. 242-248. (2011).
  9. Yoon, S. P., Kim, H. W., Lee, N. H., Kim, K. and Lee, B. S., "Change of Leachate Characteristics at Aerobic Landfill Lysimeter with Different Air Flow-rate", Journal of Korea Society of Waste Management, 29(3), pp. 275-280. (2012).
  10. Park, J. K., Lee, N. H. and Kim, N. J., "The Effect of Air Injection Quantity on Stabilization of Screened Soil in Aerobic Bioreactor Landfill", Journal of the Korea Organic Resources Recycling Association, 12(1), pp. 104-109. (2004).
  11. Yoon. S. P., Zhao, X., Lee, N. H., Jeon, Y. H., Byun, Y. D., Ahn, Y. M. and Min, J. H., "A Field Study on Early Stabilization of Waste Landfill Using Air Injection and Leachate Recirculation", Journal of the Korea Organic Resources Recycling Association, 18(2), pp. 45-54. (2010).
  12. Kim, H. J. and Lee, N. H., "Effect of Oxygen and Moisture on Stabilization of Municipal Solid Wastes in Landfill", Journal of the Korea Organic Resources Recycling Association, 14(1), pp. 139-150. (2006).
  13. Kim, K., Jeong, S. R., Yoon, S. P., Lee, B. S. and Lee, N. H., "The Suggestion of a Pre-stabilization Technology for Sustainable Solid Waste Landfill", Proceedings of the 2011 Autumn Conference of the Korea Society of Waste Management, pp. 489-491. (2011).
  14. Kim, Y. H., Park, H. S. and Choi, Y. H., "Mean Size of Droplets Ejected from Humidifier and Distributions of Relative Humidity as Affected by Different Humidifying Methods in Graft-taking Enhancement System", Journal of Bio-Environment Control, 12(1), pp. 12-16. (2003).
  15. Pommier, S., Chenu, D., Quintard, M. and Lefebvre, X., "Modelling of Moisture-dependent Aerobic Degradation of Solid Waste", Waste Management, 28(7), pp. 1188-1200. (2008). https://doi.org/10.1016/j.wasman.2007.05.002
  16. Kallel, A., Matsuto, T. and Tanaka, N., "Determination of Oxygen Consumption for Landfilled Municipal Solid Wastes", Waste Management and Research, 21(4), pp. 346-355. (2003). https://doi.org/10.1177/0734242X0302100407
  17. Haug, R., "The Practical Handbook of Compost Engineering", Lewis Publishers, Boca Raton, pp. 385-436. (1993).
  18. Petric, I. and Selimbasic, "Development and validation of mathematical model for aerobic composting process", Chemical Engineering Journal, 139(2), pp. 304-317. (2008). https://doi.org/10.1016/j.cej.2007.08.017
  19. Krivan, V., "The ideal free distribution and bacterial growth on two substrates", Theoretical Population Biology, 69(2), pp. 181-191. (2006). https://doi.org/10.1016/j.tpb.2005.07.006
  20. Kim, H. J., Jung, S. R., Park, J. K. and Lee, N. H., "Evaluation of Anaerobic Biodegradability of Organic Waste Considering Diauxic Growth", Journal of Korea Society of Waste Management, 25(7), pp. 652-658. (2008).