A Study on the Characteristics of Peak Wind Pressure Coefficient according to Type of Pilotis of High-rise Buildings

고층건물의 필로티 형태별 피크풍압계수 특성에 대한 연구

  • 김근호 (전북대학교 건축공학과 대학원) ;
  • 유장열 (송원대학교 건축공학과) ;
  • 김영문 (전북대학교 건축공학과) ;
  • 유기표 (전북대학교 건축공학과, 장경간철골구조 농촌시설물연구센터)
  • Received : 2018.01.23
  • Accepted : 2018.04.10
  • Published : 2018.04.30

Abstract

Various types of pilotis frames are used on the ground level of high-rise buildings. In some cases, their interior finishing is destroyed by strong winds or typhoons. In the case of a corner pilotis, the peak wind pressure coefficients were greater on the ceiling than they were on the wall for all wind angles. Specifically, on the ceiling portion of a pilotis, the coefficient increased gradually from the outside to the inside in a symmetrical form that centered on the corner edge. However, the minimum peak wind pressure coefficient was greater at the center of the ceiling than it was on the edge of the pilotis' interior. Additionally, the higher the height of the pilotis, the greater the peak wind pressure coefficient was due to the turbulent flow that occurs within a pilotis. In this study, we evaluated peak wind pressures to design an interior finishing for the end edge of a pilotis and for corner piloti. In terms of specific wind angles, the maximum and minimum peak wind pressure coefficients were each observed. They were a maximum of $320^{\circ}$ and a minimum of $270^{\circ}$ for corner piloti and $0^{\circ}$ and $270^{\circ}$, respectively, for the end edge piloti.

Keywords

Acknowledgement

Supported by : 한국연구재단

References

  1. Cho, C. (2006). A Study on the Planning of Wind Flow in Apartment Housing, Journal of the Urban Design Institute of Korea, 25-45.
  2. Jo, J., & Gil, Y. (2014). Evaluation of Wind Effect for Piloti Space of Buildings using Numerical Analysis Method, The Wind Engineering Institute of Korea, 47-50.
  3. Kim, J. (2013). Need for Strengthening Standards of Water-reinforce Design, Korea River Association vol.10, 92-97.
  4. Korea Building Code, (2016).
  5. Lee, J., Song, Y., & Yoo, U. (2005). A Study on the Pilotis Design Characteristics in the Highrise Apartment Housing Estates, Journal of the Korean Housing Association, 121-128.
  6. Shin, S., Park, C., & Son, E. (2015). Analyzing the Effects and Costs of Flood Protection Measures for Buildings, Journal of Korean Planning Association, 50(2), 243-260.
  7. Zeng, Z., Qinli, D., & Akashi, M. (2014). Effect of piloti on wind environment in residential area in a hot and humid cuty, Journal of the Wind Engineering Institute of Japan, 73-78.