Abstract

The increase in the size and the uptake of PV systems is leading to significant increase in the penetration of PV into local electricity grids. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The current global situation of environmental pollution, climate change and energy demand urgently requires dramatic political, economic and technical decisions in order to avoid a potential collapse of environmental and social systems. Around the world, electricity remains the vital component of national and international development. The implementation of renewable energy resources can provide solutions to these challenges by stimulating the early implementation of economically viable sustainable energy technologies.

태양광발전시스템에 대한 시험인증 기술력 향상을 위한 표준화를 위하여 기 구축된 분야에 대한 국가표준(안)을 제안 및 개정하고, 기업이 수출시 상대국이 인정하는 적합성평가(CB인증)가 국내에서 지원하는 것이 필수적이다. 이를 위하여 국제공인 적합성평가 기관으로서의 능력을 향상시켜 IECEE-CB 제도에 의한 인증기관(NCB-NREC) 및 시험기관으로의 위상 강화를 추진하여 국내기업이 수출장벽을 타개하고 외국에서 시험인증 받기 위한 기간을 단축하고 경비를 대폭 절감하여 수출의 증대 및 대외 경쟁력 확보가 필요하다. 또한 정부가 추진 중인 FTA에 교역시 기술장벽(TBT) 해소를 위한 상호인정 협정에 대비하기 위하여도 국내 시험인증기관의 능력향상이 필수적이다. 현재 태양광모듈 및 인버터의 안전성 평가는 유럽 및 일본에서 강제로 채택하여 국내업체 수출시 외국인증기관을 이용하고 있는 실정으로서 태양광모듈의 안전성 평가에 대한 CBTL를 취득함으로서 국내외 경쟁력 강화 및 태양광 발전 사업을 수출산업으로 육성지원 하는데 기여할 수 있다.

Keywords

OTNBBE_2018_v18n6_207_f0001.png 이미지

그림 1. 태양광분야 안전성 기술기준 및 성능평가 기반구축 Fig. 1. Establishment of Safety Technology Standards and Performance Evaluation Infrastructure for Photovol –taic Field

OTNBBE_2018_v18n6_207_f0002.png 이미지

그림 2. NREL의 분산전원 테스트 시설 Fig. 2. NREL's distributed power test facility

OTNBBE_2018_v18n6_207_f0003.png 이미지

그림 3. 시험 중인 다양한 계통연계 인버터 Fig. 3. Various grid-connected inverters under test

OTNBBE_2018_v18n6_207_f0004.png 이미지

그림 4. 독일 Fraunhofer ISE의 태양광 인버터 시험장비 Fig. 4. Germany Fraunhofer ISE solar inverter test equip –ment

OTNBBE_2018_v18n6_207_f0005.png 이미지

그림 5. 태양광 제품 경쟁력 강화를 위한 시험평가기반 구축 요구사항 Fig. 5. Establishment of test evaluation base for strength -ening competitiveness of PV products

References

  1. E. Troester, "New German Grid Codes for Connecting PV Systems to the Medium Voltage Power Grid", 2008
  2. FGW e.V, "Technical Guidelines for Power Generating Units Part 3", 2009
  3. BENDER, "Electrical Safety of PV installation" https://www.bender.de/en
  4. SMA Solar Technology AG "International Experience with PV Interconnection Standards" https://www.sma.de/en.html
  5. SMA Solar Technology AG, "Transformerless Photovoltaic Inverter Technology Safety, Electri -cal Design and Operation" https://www.sma.de/en.html
  6. Michael A. Quintana, "Utility Scale PV Inverter Reliability Workshop", Sandia National Laboratories. 2011.
  7. IEC 62109-1, Safety of Power Converters for use in Photovoltaic Power Systems - Part 1
  8. IEC 62109-2, Safety of Power Converters for use in Photovoltaic Power Systems-Part 2
  9. P. Suwanapingkarl, A. Singhasathein, Nattaphong Phanthuna, "Impacts of Green Technologies in Distribution Power Network", International Journal of Advanced Culture Technology, Vol.3 No.1, pp. 90-100, 2015. DOI: http:// doi.org/10.17703/IJACT.2015.3.1.90
  10. S.Y. Choi, "Building Energy Management System with Next Day Demand Forecasting of Building Load," The Journal of The Institute of Internet, Broadcasting and Communication(JIIBC), Vol. 14, No. 6, pp. 119-123, 2014. DOI: http:// doi.org/10.7236/JIIBC.2014.14.6.119
  11. G.S. Seo, "Transient Stability Enhancement of Power System by Using Energy Storage System," Journal of the Korea Academia-Industrial cooperation Society(JKAIS), Vol. 18, No. 12, pp. 26-31, 2017. DOI: https://doi.org/10.5762/KAIS.2017.18.12.26