Metal artifact production and reduction in CBCT with different numbers of basis images

  • Queiroz, Polyane Mazucatto (Department of Oral Diagnosis, Area of Oral Radiology, Piracicaba Dental School, University of Campinas) ;
  • Santaella, Gustavo Machado (Department of Oral Diagnosis, Area of Oral Radiology, Piracicaba Dental School, University of Campinas) ;
  • Groppo, Francisco Carlos (Department of Physiological Sciences, Area of Pharmacology, Piracicaba Dental School, University of Campinas) ;
  • Freitas, Deborah Queiroz (Department of Oral Diagnosis, Area of Oral Radiology, Piracicaba Dental School, University of Campinas)
  • Received : 2017.10.16
  • Accepted : 2018.01.31
  • Published : 2018.03.31

Abstract

Purpose: To evaluate the effect of different numbers of basis images and the use of metal artifact reduction (MAR) on the production and reduction of artifacts in cone-beam computed tomography images. Materials and Methods: An acrylic resin phantom with a metal alloy sample was scanned, with 450 or 720 basis images and with or without MAR. Standard deviation values for the test areas (around the metal object) were obtained as a way of measuring artifact production. Two-way analysis of variance was used with a 5% significance level. Results: There was no significant difference in artifact production among the images obtained with different numbers of basis images without MAR (P=.985). MAR significantly reduced artifact production in the test areas only in the protocol using 720 basis images (P=.017). The protocol using 450 basis images with MAR showed no significant difference in artifact production when compared to the protocol using 720 basis images with MAR (P=.579). Conclusion: Protocols with a smaller number of basis images and with MAR activated are preferable for minimizing artifact production in tomographic images without exposing the patient to a greater radiation dose.

Keywords

References

  1. Scarfe WC, Farman AG, Sukovic P. Clinical applications of cone-beam computed tomography in dental practice. J Can Dent Assoc 2006; 72: 75-80.
  2. Vande Berg B, Malghem J, Maldague B, Lecouvet F. Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware. Eur J Radiol 2006; 60: 470-9. https://doi.org/10.1016/j.ejrad.2006.08.008
  3. Draenert FG, Coppenrath E, Herzog P, Muller S, Mueller-Lisse UG. Beam hardening artefacts occur in dental implant scans with the NewTom cone beam CT but not with the dental 4-row multidetector CT. Dentomaxillofac Radiol 2007; 36: 198-203. https://doi.org/10.1259/dmfr/32579161
  4. Schulze R, Heil U, Gross D, Bruellmann DD, Dranischnikow E, Schwanecke U, et al. Artefacts in CBCT: a review. Dentomaxillofac Radiol 2011; 40: 265-73. https://doi.org/10.1259/dmfr/30642039
  5. Kamburoglu K, Kolsuz E, Murat S, Eren H, Yuksel S, Paksoy CS. Assessment of buccal marginal alveolar peri-implant and periodontal defects using a cone beam CT system with and without the application of metal artefact reduction mode. Dentomaxillofac Radiol 2013; 42: 20130176. https://doi.org/10.1259/dmfr.20130176
  6. Bechara B, McMahan CA, Nasseh I, Geha H, Hayek E, Khawam G, et al. Number of basis images effect on detection of root fractures in endodontically treated teeth using a cone beam computed tomography machine: an in vitro study. Oral Surg Oral Med Oral Pathol Oral Radiol 2013; 115: 676-81. https://doi.org/10.1016/j.oooo.2013.01.026
  7. Bezerra IS, Neves FS, Vasconcelos TV, Ambrosano GM, Freitas DQ. Influence of the artefact reduction algorithm of Picasso Trio CBCT system on the diagnosis of vertical root fractures in teeth with metal posts. Dentomaxillofac Radiol 2015; 44: 20140428. https://doi.org/10.1259/dmfr.20140428
  8. Scarfe WC, Farman AG. What is cone-beam CT and how does it work? Dent Clin North Am 2008; 52: 707-30. https://doi.org/10.1016/j.cden.2008.05.005
  9. Wenzel A, Sewerin I. Sources of noise in digital subtraction radiography. Oral Surg Oral Med Oral Pathol 1991; 71: 503-8. https://doi.org/10.1016/0030-4220(91)90441-E
  10. Spin-Neto R, Matzen LH, Schropp L, Gotfredsen E, Wenzel A. Movement characteristics in young patients and the impact on CBCT image quality. Dentomaxillofac Radiol 2016; 45:20150426. https://doi.org/10.1259/dmfr.20150426

Cited by

  1. Digital three-dimensional visualization of intrabony periodontal defects for regenerative surgical treatment planning vol.20, pp.1, 2018, https://doi.org/10.1186/s12903-020-01342-w
  2. Application of an auto-edge counting method for quantification of metal artifacts in CBCT images: a multivariate analysis of object position, field of view size, tube voltage, and metal artifact reduc vol.132, pp.6, 2018, https://doi.org/10.1016/j.oooo.2021.03.012