Abstract
This paper describes the experimental results for the structural performance of full-scale coupling beams with different reinforcement layout (diagonal and horizontal). For the reinforcements of the coupling beams, high-strength steel bars(SD500 and SD600) were used in order to improve workability and economic feasibility. The rigid steel frames and linked joints were used to maintain the clear span length (distance between both shear walls) of the coupling beam during the cyclic loading. Experimental results indicated that the diagonally reinforced coupling beam specimen could exhibit more ductile behavior compared to horizontally reinforced specimen. ACI318-14 code is applicable to design of coupling beam with diagonally reinforcement, however, that is overestimating the strength of horizontally reinforced coupling beam. It is remarkable that effective elastic stiffness values of both reinforcement details coupling beam significantly lees than ASCE 41-13.
본 연구는 철근상세(대각선 및 수평 철근상세)가 실규모 연결보의 구조성능에 미치는 영향을 평가하기 위하여 실시되었다. 연결보의 시공성 및 경제성을 향상시키기 위하여 고강도 철근(SD500 및 SD600)을 사용하였다. 반복하중이 작용하는 동안 연결보의 순경간(양쪽 전 단벽 사이의 간격)을 유지하기 위하여 강체 프레임 및 링크조인트를 설치하였다. 실험결과 대각선 철근상세을 적용한 연결보가 수평 철근상세 연결보에 비해 높은 연성을 나타내었다. AC1318-14 기준은 대각선 철근상세의 연결보 설계에는 적용이 가능할 것으로 판단되나, 수평 철근상세 연결보의 최대내력은 과대평가하는 것으로 나타났다. ASCE 41-13에서 제시된 연결보의 유효강성은 대각선 및 수평 철근상세를 적용한 연결보의 실험결과를 과대평가하고 있는 것으로 판단된다.