초록

Ibuprofen is one of the most popular analgesic and antipyretic drugs. An isotope dilution mass spectrometry method based on LC/MS was developed as a candidate reference method for the accurate determination of ibuprofen in pharmaceutical tablets. Isotope labelled ibuprofen, $ibuprofen-d_3$, was added as an internal standard into sample extracts. Ibuprofen and $ibuprofen-d_3$, was analysed by LC/MS in a selected ion monitoring (SIM) mode to detect ions at m/z 205 and 208, respectively. The repeatability and reproducibility of the developed ID-LC/MS method were tested for the validation and assessment of metrological quality of the method.

키워드

참고문헌

  1. Huidobro, A. L.; Ruperez, F. J.; Barbas, C. J. Chromatogr. A 2006, 1119, 238. https://doi.org/10.1016/j.chroma.2005.11.090
  2. Gasco-Lopez, A. I.; Izquierdo-Hornillos, R.; Jimenez. A. J. Pharm. Biomed. Anal. 1999, 21, 143. https://doi.org/10.1016/S0731-7085(99)00127-2
  3. Sun, Y.; Takaba, K.; Kido, H.; Nakashima, M. N.; Nakashima, K. J. Pharm. Biomed. Anal. 2003, 30, 1611. https://doi.org/10.1016/S0731-7085(02)00549-6
  4. Whelan, M. R.; Ford, J. L.; Powell, M. W. J. Pharm. Biomed. Anal. 2002, 30, 1355. https://doi.org/10.1016/S0731-7085(02)00394-1
  5. Tsikas, D.; Kayacelebi, A. A.; Hanff, E.; Mitschke, A.; Beckmann, B.; Tillmann, H.-C.; Gutzk, F.-M.; Muller, M.; Bernasconi. C. J. Chromatogr. B 2017, 1043, 158. https://doi.org/10.1016/j.jchromb.2016.06.014
  6. Stubberud, K. P.; Astron, O. J. Chromatogr. A 1998, 826, 92.
  7. Hamoudova, R.; Pospisilova, M. J. Pharm. Biomed. Anal. 2006, 41, 1463. https://doi.org/10.1016/j.jpba.2006.03.024
  8. Palabiyik, I. M.; Dinc, E.; Onur, F. J. Pharm. Biomed. Anal. 2004, 34, 473. https://doi.org/10.1016/S0731-7085(03)00578-8
  9. Alnouti, Y.; Srinivasan, K.; Waddell, D.; Bi, H.; Kavetskaia, O.; Gusev, A. I. J. Chromatogr. A 2005, 1080, 99. https://doi.org/10.1016/j.chroma.2005.04.056
  10. Wu, J.; Qian, X.; Yang, Z.; Zhang, L. J. Chromatogr. A 2010, 1217, 1471. https://doi.org/10.1016/j.chroma.2009.12.074
  11. Quinn, T. J. Metrologia 1997, 34, 61. https://doi.org/10.1088/0026-1394/34/1/9
  12. Lee, J.; Jang, E. S.; Kim, B. Anal. Chim. Acta 2013, 787, 132. https://doi.org/10.1016/j.aca.2013.05.034
  13. Shin, H.; Kim, B.; Lee, J. Food Chem. 2013, 138, 1109. https://doi.org/10.1016/j.foodchem.2012.11.046
  14. Lee, J.; Song, Y.-S.; Sim, H.-J.; Kim, B. J. Food Compos. Anal. 2016, 50, 49. https://doi.org/10.1016/j.jfca.2016.05.008
  15. Shin, H.; Kim, B.; Lee, J., Hwang, E. Bull. Kor. Chem. Soc. 2010, 31, 3663. https://doi.org/10.5012/bkcs.2010.31.12.3663