DOI QR코드

DOI QR Code

Fitness of heat - pressed ceramic laminate veneer using additive manufacturing process: 3 Dimensional analysis

적층가공방식을 이용한 열가압 세라믹 라미네이트 비니어의 적합도: 3차원 분석

  • Kang, Seen-Young (Department of Public Health Science, Graduate school, Korea University) ;
  • Lee, Ha-Na (Department of Public Health Science, Graduate school, Korea University) ;
  • Kim, Eo-Bin (Department of Public Health Science, Graduate school, Korea University) ;
  • Lee, Kyung-Eun (Department of Public Health Science, Graduate school, Korea University) ;
  • Kim, Ji-Hwan (Department of Public Health Science, Graduate school, Korea University) ;
  • Kim, Woong-Chul (Department of Public Health Science, Graduate school, Korea University)
  • 강신영 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 이하나 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 김어빈 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 이경은 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 김지환 (고려대학교 대학원 보건과학과 치의기공전공) ;
  • 김웅철 (고려대학교 대학원 보건과학과 치의기공전공)
  • Received : 2017.05.25
  • Accepted : 2017.09.15
  • Published : 2017.09.30

Abstract

Purpose: The purpose of this study is to analyze the fitness of heat - pressed ceramic laminate veneers fabricated using the additive manufacturing. Methods: Impression was replicated by using light body silicone and heavy body silicone on the custom tray, and it was fabricated using Type IV Stone. The test specimens were prepared by using a dental scanner, a laminating veneer using a dental design program, and a specimen with a 3D printer. The control specimens were prepared by the lost wax technique and heat - pressed to fabricate the specimens. The data of the specimens were measured by the RMS value of the internal fitness a using a 3-dimensional measurement program. Results: The Stereolithography laminate veneer group was measured at $78.10(4.09){\mu}m$ and the LWV group was measured at $31.50(5.10){\mu}m$. There is a significant difference between the two groups (p<0.001) Conclusion : Evaluation of fitness laminate veneers was fabricated by additive manufacturing showed the difference statistically significantly and clinically acceptable result.

Keywords

References

  1. Aboushelib MN, Elmahy WA, Ghazy MH. Internal Adaptation, Marginal Accuracy and Microleakage of a Pressable Versus a Machinable Ceramic Laminate Veneers. J Dent, 40(8), 670-677, 2012. https://doi.org/10.1016/j.jdent.2012.04.019
  2. Alajaji NK, Bardwell D, Finkelman M, Ali A. Micro-Ct Evaluation of Ceramic Inlays: Comparison of the Marginal and Internal Fit of Five and Three Axis Cam Systems with a Heat Press Technique. J Esthet Restor Dent, 2016.
  3. Bae SY, Park JY, Jeong ID, Kim HY, Kim JH, Kim WC. Three-Dimensional Analysis of Marginal and Internal Fit of Copings Fabricated with Polyetherketoneketone (Pekk) and Zirconia. J Prosthodont Res, 61(2), 106-112, 2017. https://doi.org/10.1016/j.jpor.2016.07.005
  4. Berger U. Aspects of accuracy and precision in the additive manufacturing of plastic gears. Virtual Phys Prototype, 10(2), 49-57, 2015. https://doi.org/10.1080/17452759.2015.1026127
  5. De Beer N. Advances in Three Dimensional Printing-State of the Art and Future Perspectives. J for New Generation Sciences, 4(1), 21-49, 2006.
  6. Dehurtevent M, Robberecht L, Behin P. Influence of Dentist Experience with Scan Spray Systems Used in Direct Cad/Cam Impressions. J Prosthet Dent, 113(1), 17-21, 2015. https://doi.org/10.1016/j.prosdent.2014.07.006
  7. Ghaffari T, Hamedi-Rad F, Fakhrzadeh V. Marginal Adaptation of Spinell Inceram and Feldspathic Porcelain Laminate Veneers. Dent Res J, 13(3), 239, 2016 https://doi.org/10.4103/1735-3327.182183
  8. Han MS. An evaluation of quality of dental prostheses printed by dental 3-dimensional printing system. J Korean Acad Dent Tech, 38(3), 188-191, 2016.
  9. Kim CM, Jeon JH, Lee JJ, Kim JH, Kim WC. Precision Evaluation of Crown Prosthesis Manufactured by Two Bur and Three Bur. J Korean Acad Dent Tech, 38(2), 57-62, 2016. https://doi.org/10.14347/kadt.2016.38.2.57
  10. Kim KB, Kim JH, Kim WC, Kim HY, Kim JH. Marginal fit evaluation of 3 unit fixed dental prostheses fabricated by rapid prototyping method. J Korean Acad Dent Tech, 34(2) 105-11. 2012. https://doi.org/10.14347/kadt.2012.34.2.105
  11. Kim KB, Kim JH, Kim WC, Kim HY, Kim JH. Evaluation of the Marginal and Internal Gap of Metal-Ceramic Crown Fabricated with a Selective Laser Sintering Technology: Twoand Three- dimensional replica techniques. J Adv Prosthodont, 5(2), 179-86, 2013. https://doi.org/10.4047/jap.2013.5.2.179
  12. Dehurtevent M, Robberecht L, Behin P. Influence of dentist experience with with scan spray system used indirect CAD/CAM impressions. J Prosthet Dent, 113(1), 17-21, 2015. https://doi.org/10.1016/j.prosdent.2014.07.006
  13. Neves FD, Prado CJ, Prudente MS, Carneiro TA, Karla Zancope K, Davi LR, Mendonca G, Cooper LF, Soares CJ. Micro-Computed Tomography Evaluation of Marginal Fit of Lithium Disilicate Crowns Fabricated by Using Chairside Cad/Cam Systems or the Heat-Pressing Technique. J Prosthet Dent, 112(5), 1134-1140, 2014. https://doi.org/10.1016/j.prosdent.2014.04.028
  14. Oh SC, Dong JK, Luthy H, Scharer P. Strength and Microstructure of Ips Empress 2 Glass-Ceramic after Different Treatments. Int J Prosthodont, 13(6), 468-472, 2000.
  15. Oh SC, Shin YH. Esthetic restoration of upper anterior teeth by porcelain laminate veneer. J Dent Rehabil appl Sci, 19(1), 35-41, 2003.
  16. Schaefer O, Watts DC, Sigusch BW, Kuepper H, Guentsch A. Marginal and Internal Fit of Pressed Lithium Disilicate Partial Crowns in Vitro: A Three-Dimensional Analysis of Accuracy and Reproducibility. Dent Mater, 28(3), 320-326, 2012. https://doi.org/10.1016/j.dental.2011.12.008
  17. Sorensen, JA. A Standardized Method for Determination of Crown Margin Fidelity. J Prosthet Dent, 64(1), 18-24, 1990. https://doi.org/10.1016/0022-3913(90)90147-5
  18. Ural C, Burgaz Y, Sarac D. In Vitro Evaluation of Marginal Adaptation in Five Ceramic Restoration Fabricating Techniques, Quintessence Int, 41(7), 585-590, 2010.
  19. Van Noort R. Richard. The Future of Dental Devices is Digital. Dent Mater, 28(1), 3-12, 2012. https://doi.org/10.1016/j.dental.2011.10.014
  20. Zanotto ED. Bright Future for Glass-Ceramics. American Ceramics Society Bulletin, 89(8), 19-27, 2010.