Study on the Cable Wall System Applied to Reinforced Concrete Exterior

철근콘크리트구조 외장재에 케이블월 시스템 적용에 관한 연구

  • 박현수 (신한대학교 디자인학부)
  • Received : 2017.01.20
  • Accepted : 2017.03.10
  • Published : 2017.03.31

Abstract

Development of a facade system that can reduce load factor and costs in high-rise building construction is required. The proposed cable wall system is used as a structural support by the glass-cable and can increase openness on lower elevations and the lobby area. Its use in high-rise buildings can reduce construction costs. Without transferring directly a strong initial tension of the cable to the building frame is connected to the steel member and the reinforced concrete structures, by absorbing the initial tension of the cable, it is possible to control the occurrence of a strong concentrated loads to the structure. Comparison of load-displacement test results from the numerical analysis with the test results showed reasonable agreement, Therefore, the proposed numerical results confirm good prediction of cable behavior for the facade system.

본 연구는 건축외장재에 케이블을 이용하여 로비공간에 개방성이 확보되고 시공이 간단하여 공사비용을 절감시킬 수 있는 케이블월 시스템을 제안하였다. 제안된 케이블월 시스템은 외장재의 하중을 지탱하기 위해 건축물에 철골구조를 과대하게 설치하는 기존 커튼월 구조와는 다르게 케이블을 철골부재와 철근콘크리트구조로 연결하므로 구조시스템의 단순화와 개방성을 확보할 수 있다. 또한 수직 케이블에 초기장력을 가력 할 경우 케이블접합부에 압축력이 작용되어 유리패널을 효과적으로 가압 고정할 수 있을 뿐만 아니라 풍하중을 효과적으로 구조물에 전달할 수 있게 되었다. 본 연구에서 제안한 케이블월 이론식을 구조해석 프로그램인 MIDAS-GEN에 이용하여 얻어진 해석 값을 구조실험값과 비교한 결과 하중-변형값이 유사한 것으로 나타났으며, 구조실험에 나타난 최대 처짐 값(57.5mm)은 외국 외장재 처짐규준 AAMA(L/60=150mm)보다는 매우 작게 발생되어 제안된 케이블월 시스템을 사용할 경우 구조성능은 충분히 만족하는 것으로 확인되었다.

Keywords

Acknowledgement

Supported by : 중소기업청

References

  1. Korea Super Tall Building Forum, "Super Tall Building Design and Teclmology", pp. 12-37, 2007.
  2. Korean Association for Spatial Structures, "Design Code and Commentary for Cable Structures", pp. 93-109, 2009.
  3. Gang SHI, Yongzhi ZUO, Xiaohao SHI, Yongjiu SHI, Yuanqing WANG, Zaoyang GUO, "Influence of Damages on Static Behavior of Single-layer Cable Net Supported Glass Curtain Wall: Full-scale Model Test, Research Article", pp. 382-395, 2010. DOl: http://doi.org/10.1007/s11709-010-0074-6
  4. Gang SHI, "Influence of Damage on Static Behavior of Single-layer Cable Net Supported Glass Curtain Wall", Journal of Constructional Steel Research, pp. 54-78, 2010.
  5. Ruo-qiang Feng, Ii-hong Ye, Yue Wu, Shi-zhao Shen, "Mechanical Behavior of Glass Panels Supported by Clamping Joints in Cable Net Facades", Journal of Steel Structures, pp. 213-305, 2012. DOI: http://doi.org/10.1007/s13296-012-1002-5
  6. AAMA, "Maximum Allowable Deflection of Framing Systems for Building Cladding Components at Design Wind Loads", pp. 33-72, 1996.
  7. MIDAS Information Technology Co. Ltd. "Analysis & Design" pp. 14-81 , 2014.
  8. AAMA MCWM-1-89, "Metal Curtain Wall Manual", pp. 9-18, 2010.
  9. Park, Sun-Woo, "Structural Glass-system in Roof and Facade", Korean Association for Spatial Structures, pp. 1-28, 2002.