참고문헌
- Lee, D. W., Cho, Y. H., 2008, A Continuous Electrical Cell lysis Chip using a DC Bias Voltage for Cell Disruption and Electroosmotic Flow, KSME, 32:10 831-835. https://doi.org/10.3795/KSME-A.2008.32.10.831
- Ha, S. M., Cho, W., Ahn, Y. M., Hwang, S. Y., 2010, Study on Microbiochip for Buccal Cell Lysis and DNA Purification, KSME, 34:12 1785-1791. https://doi.org/10.3795/KSME-A.2010.34.12.1785
- Kim, J., Hong, J. W., Kim, D. P., Shin, Jeniffer H., Park, I. K., 2012, Nanowire-Integrated Microfluidic Devices for Facile and Reagent-free Mechanical Cell Lysis, Lap Chip, 12 2914-2921. https://doi.org/10.1039/c2lc40154a
- Jen, C. P., Amstislavskaya, Tamara. g., Liu, Y. H., Hsiao, J. H., Chen, Y. H., 2012, Single-cell Electric Lysis on an Electroosmotic-Driven Fig Microfluidic Chip with Arrays of Microwells, Sensors, 12 6967-6977. https://doi.org/10.3390/s120606967
- Yun, S. S., Yoon, S. Y., Song, M. K., Im, S. H., Lee, J. H., Yang, S., 2010, Handheld Mechanical Cell Lysis Chip with Ultra-sharp Silicon Nano-Blade Arrays for Rapid Intracellular Protein Extraction, Lap chip, 10 1442-1446. https://doi.org/10.1039/b925244d
- So, H. Y., Lee, K. W., Seo, Y. H., Murthy, N., Pisano, Albert. P., 2014, Hierarchical Silicon Nanospikes Membrane for Rapid and High-Throughput Mechanical Cell Lysis, ACSAMI, 6 6993-6997.
- Carlo, D. D., Jeong, K. H., Lee, Luke. P., 2003, Reagentless Mechanical Cell Lysis by Nanoscale Barbs in Microchannels for Sample Preparation, Lap chip, 3 287-291. https://doi.org/10.1039/b305162e
- Brown, R. B., Audet, J., 2008, Current Techniques for Single-cell Lysis, J. R. Soc. Interface, 5 S131-S138. https://doi.org/10.1098/rsif.2008.0009.focus
- Tsukada, K., Sekizuka, E., Oshio, C., Minamitani, H., 2001, Direct Measurement of Erythrocyte Deformability in Diabetes Mellitus with a Transparent Microchannel Capillary Model and High-Speed Video Camera System, Microvascular Research, 61 231-239. https://doi.org/10.1006/mvre.2001.2307
- Hou, H. W., Li, Q. S., Lee, G. Y. H., Kumar, A. P., Ong, C. N., Lim, C. T., 2009, Deformability Study of Breast Cancel Cells Using Microfluidics, Biomed Microdevices, 11 557-564. https://doi.org/10.1007/s10544-008-9262-8
- Shin, H, G., Kwon, J. T., Seo, Y. H., Kim, B. H., 2008, Properties of Pore Generation by Variation of Temperature in AAO Process, Proceeding of KSMTE, 371-374.
- Park, Y. M., Shin, H. G., Seo, Y. H., Kim, B. H., 2009, Fabrication of Polymer Replica with Nano Patterns Using Porous Alumina Structure, Proceeding of KSMTE, 456-459.
- Sambrook, J., Russell, David. W., 1982, Molecular Cloning: A Laboratory Manual, Cold Spring Harbor, New York, USA.
피인용 문헌
- Development of Vacuum Thin-Film-Forming Mold using Porous Aluminum vol.29, pp.6, 2017, https://doi.org/10.7735/ksmte.2020.29.6.435