연구용 원자로 내부에 설치되는 이차정지구동장치의 내진낙하성능

Seismic Drop Performance for Second Shutdown Drive Mechanism Installed in Research Reactor

  • 투고 : 2016.07.12
  • 심사 : 2016.08.30
  • 발행 : 2016.11.20

초록

The second shutdown drive mechanism (SSDM) that is classified into seismic category I as an active mechanical equipment shall maintain the structural integrity and its designed inherent safety functions during and/or after normal operation, anticipated operational occurrences, accidents and seismic occurrences. Therefore, not only a structural integrity assessment through numerical analyses but also a qualification test by using the prototype SSDM shall be conducted to verify the adequacy of the SSDM design. This paper describes a sort of seismic qualification test of the prototype SSDM to demonstrate that the structural integrity and operability (functionality) of SSDM are maintained during and/or after seismic excitations. From the results, this paper shows that the SSDM satisfies all design requirements without any malfunctions during and after the seismic test.

키워드

참고문헌

  1. Kim, S., Kim, G. H., Sun, J. O., Cho, Y. G., Kim, J. H. et al., 2016, Seismic Qualification for Second Shutdown Drive Mechanism of JRTR, Proceedings of the KSNVE Annual Spring Conference, pp. 247~250.
  2. Kim, S., Kim, G. H., Sun, J. O., Cho, Y. G., Jung, T. H. et al., 2016, Seismic Qualification Test for SSDM Hydraulic System of Research Reactor, Transactions of Korean Society of Pressure Vessel and Piping (KPVP), Vol 12, No. 1, pp. 23~29. https://doi.org/10.20466/KPVP.2016.12.1.023
  3. US NRC Regulatory Guide 1.29, 2007, Seismic Design Classification, Rev. 4. Nuclear Regulatory Commission.
  4. US NRC Regulatory Guide 1.100, 1988, Seismic Qualification of Electric and Mechanical Equipment for Nuclear Power Plants, Rev. 2, Nuclear Regulatory Commission.
  5. NSSC Regulatory Guide KINS/RG-N03.02, 2011, Seismic Qualification of Mechanical and Electric Equipment for Nuclear Power Plants, Nuclear Safety andSecurity Commission.
  6. IEEE 344, 1987, Recommended Practice for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations, IEEE Power Engineering Society.
  7. KEPIC END 2000, 2005 through 2006 addenda, Seismic Qualification of Class 1E Equipment, Korea Electric Association.
  8. IEEE 600, 1983, Trial-use Standard Requirements for Organizations that Conduct Qualification Testing Safety Systems Equipment for Use in Nuclear Power Generating Stations, IEEE Power Engineering Society.
  9. KEPIC END 1200, 2005, Organizations that Conduct Qualification Testing Safety Systems Equipment, Korea Electric Association.
  10. ASME QME-1, 1997, Qualification of Active Mechanical Equipment Used in Nuclear Power Plants, American Society of Mechanical Engineers.
  11. KEPIC MF, 2005 through 2006 addenda, Qualification of Active Mechanical Equipment Used in Nuclear Power Plants, Korea Electric Association.
  12. IEEE 323, 2003, Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations, IEEE Power Engineering Society.
  13. KEPIC END 1100, 2005, Qualifying Class 1E Equipment, Korea Electric Association.
  14. NSSC Regulation No.3, 2011, Regulation on Standards of Nuclear Reactor Facilities, Nuclear Safety and Security Commission.
  15. IAEA Safety Requirements NS-R-4, 2005, Safety Standards, Safety of Research Reactors, International Atomic Energy Agency.
  16. NSSC Regulation 2012-9, 2012, Regulation on Safety Classification and Applicable Codes and Standards for Nuclear Reactor Facilities, Nuclear Safety and Security Commission.
  17. NSSC Notice 2012-13, 2012, Guideline on Applicable Korea Electric Power Industry Code for Nuclear Reactor Facilities, Nuclear Safety and Security Commission.
  18. KEPIC MNG, 2005 Through 2006 Addenda, Core Support Structures, Korea Electric Association.
  19. NSSC Notice 2012-17, 2012, Regulation on Standards for Quality Assurance Requirements of Reactor Facilities, Nuclear Safety and Security Commission.
  20. ASME NQA-1, 1994, Quality Assurance Requirements for Nuclear Facility Applications, American Society of Mechanical Engineers.
  21. KEPIC QAP, 2005, Nuclear Quality Assurance Requirements, Korea Electric Association.