DOI QR코드

DOI QR Code

Simulation of Containment Pressurization in a Large Break-Loss of Coolant Accident Using Single-Cell and Multicell Models and CONTAIN Code

  • 투고 : 2015.09.26
  • 심사 : 2016.03.16
  • 발행 : 2016.10.25

초록

Since the inception of nuclear power as a commercial energy source, safety has been recognized as a prime consideration in the design, construction, operation, maintenance, and decommissioning of nuclear power plants. The release of radioactivity to the environment requires the failure of multiple safety systems and the breach of three physical barriers: fuel cladding, the reactor cooling system, and containment. In this study, nuclear reactor containment pressurization has been modeled in a large break-loss of coolant accident (LB-LOCA) by programming single-cell and multicell models in MATLAB. First, containment has been considered as a control volume (single-cell model). In addition, spray operation has been added to this model. In the second step, the single-cell model has been developed into a multicell model to consider the effects of the nodalization and spatial location of cells in the containment pressurization in comparison with the single-cell model. In the third step, the accident has been simulated using the CONTAIN 2.0 code. Finally, Bushehr nuclear power plant (BNPP) containment has been considered as a case study. The results of BNPP containment pressurization due to LB-LOCA have been compared between models, final safety analysis report, and CONTAIN code's results.

키워드

참고문헌

  1. B. De Boeck, A review of containment accidents, Nucl. Eng. Des. 145 (1993) 279-288. https://doi.org/10.1016/0029-5493(93)90239-6
  2. I. Kljenak, B. Mavko, Simulation of containment thermal-hydraulics in the Marviken Blowdown 16 experiment with ASTEC and CONTAIN codes, Nucl. Eng. Des. 241 (2011) 1063-1070. https://doi.org/10.1016/j.nucengdes.2010.06.015
  3. D. Papini, D. Grgic, A. Cammi, M.E. Ricotti, Analysis of different containment models for IRIS small break LOCA, using GOTHIC and RELAP5 codes, Nucl. Eng. Des. 241 (2011) 1152-1164. https://doi.org/10.1016/j.nucengdes.2010.06.016
  4. T.-M. Kim, J.-H. Park, A containment analysis for SBLOCA in the refurbished Wolsong-1 nuclear power plant, Nucl. Eng. Des. 241 (2011) 3804-3811. https://doi.org/10.1016/j.nucengdes.2011.06.040
  5. O.E. Ozdemir, T.L. George, M.D. Marshall, Fukushima Daiichi Unit 1 power plant containment analysis using GOTHIC, Ann. Nucl. Energy 85 (2015) 621-632. https://doi.org/10.1016/j.anucene.2015.06.017
  6. O. Noori-Kalkhoran, M. Rahgoshay, A. Minuchehr, A.S. Shirani, Analysis of thermal-hydraulic parameters of WWER-1000 containment in a large break LOCA, Ann. Nucl. Energy 68 (2014) 101-111. https://doi.org/10.1016/j.anucene.2014.01.009
  7. Y.-S. Chen, Y.-R. Yuann, L.-C. Dai, Lungmen ABWR containment analyses during short-term main steam line break LOCA using GOTHIC, Nucl. Eng. Des. 247 (2012) 106-115. https://doi.org/10.1016/j.nucengdes.2012.02.012
  8. A. Lin, Y.-S. Chen, Y.-R. Yuann, Kuosheng Mark III containment analyses using GOTHIC, Nucl. Eng. Des. 263 (2013) 255-262. https://doi.org/10.1016/j.nucengdes.2013.05.005
  9. G. Jimenez, C. Serrano, E. Lopez-Alonso, M.d.C. Molina, D. Calvo, J. Garcia, C. Queral, J.V. Zuriaga, M. Gonzalez, BWR Mark III containment analyses using a GOTHIC 8.0 3D model, Ann. Nucl. Energy 85 (2015) 687-703. https://doi.org/10.1016/j.anucene.2015.06.025
  10. F.P. Incropera, D.P. DeWitt, Fundamentals of Heat Transfer, Wiley, Hoboken, NJ, 1981.
  11. D. Brosche, H. Karwat, The Development of Pressure Differentials across Containments of Large Water Cooled Power Reactors, Institut fur MeB- und Regelungstechnik, Technische Hochschule, Berlin, Germany, 1967.
  12. R.B. Bird, W.E. Stewart, E.N. Lightfoot, Transport Phenomena, Wiley, Hoboken, NJ, 2007.
  13. Sandia National Laboratories, Code Manual for CONTAIN 2.0: a Computer Code for Nuclear Reactor Containment Analysis, Albuquerque, NM, 1997.
  14. Atomic Energy Organization of Iran, Final Safety Analysis Report of BNPP, Tehran, Iran, 2007.