DOI QR코드

DOI QR Code

An Experimental Study on Comparing Solar Heat Shading Performances in Accordance with the Type of Internal Blinds in the Summer

하절기 내측 블라인드의 유형별 일사차폐성능 비교 실측연구

  • Park, Eun-Mi (Department of Architecture, Graduate School, Catholic University of Daegu) ;
  • Choi, Dong-Ho (Department of Architecture, Catholic University of Daegu)
  • 박은미 (대구가톨릭대학교 대학원 건축학과) ;
  • 최동호 (대구가톨릭대학교 건축학부)
  • Received : 2015.03.05
  • Accepted : 2016.08.10
  • Published : 2016.08.30

Abstract

The purpose of this study was to compare heat shading performance of various blind types in summer. 4 types of blinds were employed and the results are summarized as follows: 1) There were significant differences in indoor thermal environment and heat shading performance between different heat shading devices, and functional blinds demonstrated relatively superior heat shading performance. 2) Indoor long wave radiation influx measures were lowest for the coating roll blind (Blind B), followed by the coating venetian blind (Blind C), the venetian blind (Blind A), the roll blind, and not having any blinds at all. 3) Such examination results carry implications to reduce cooling load and enhance the indoor environment.

Keywords

References

  1. Jang, S. H., Development of heat energy controllable multi-functional window systems, Ministry of Construction Transportation, 2010
  2. Hwang, D. S., Lee. K. H., A Study on the Change of Indoor Thermal Environment According to the location of Blinds, Journal of the Korean Solar Energy Society, Vol. 31, No. 5, pp. 113-118, 2011 https://doi.org/10.7836/kses.2011.31.5.113
  3. Yoon, K. C., Kim, K. S., An Evaluation of Energy Performance in an Office with Venetian Blinds in Summer, Journal of the Architectural Institute of Korea, Vol. 28, No. 1, pp. 285-292, 2012
  4. Lee, H. J., Ku, H. Y., Koo, S. Y., You, Y. D., Yeo, M. S., Kim, K. W., An Experimental Study of Performance Evaluation on an Automated Venetian Blind, Proceeding of Annual Conference of the Architectural Institute of Korea, Vol. 28, No. 1, pp. 619-622, 2008
  5. Yoon, Y. B., Kim, D. S., Park, J. W., Lee, K. H., A Study on the Building Energy Performance Depending on the Blind Location, Blind Operation and Glazing Type, Journal of the Architectural Institute of Korea, Vol. 29, No. 7, pp. 309-316, 2013
  6. Chung, J. W., Suh, H. S., Tae, C. S., Study on Energy Saving Effects of Glass Coating Materials to Reduce Solar Radiation, Proceeding of Summer Annual Conference of Air-conditioning and Refrigeration, pp. 825-830, 2011
  7. Park, E. M., Choi, D. H., Park, M. Y., Lee, K. H., Comparing Solar Heat Shading Performances of Internal Blinds in the summer, Journal of the Korean Solar Energy Society, Vol. 34, No. 6, pp. 75-83, 2014 https://doi.org/10.7836/KSES.2014.34.6.075