DOI QR코드

DOI QR Code

Effects of electrochemical oxidation of carbon fibers on interfacial shear strength using a micro-bond method

  • Kim, Dong-Kyu (R&D Division, Korea Institute of Carbon Convergence Technology) ;
  • An, Kay-Hyeok (R&D Division, Korea Institute of Carbon Convergence Technology) ;
  • Bang, Yun Hyuk (Hyosung R&DB Labs) ;
  • Kwac, Lee-Ku (Department of Carbon Fusion Engineering, Jeonju University) ;
  • Oh, Sang-Yub (R&D Division, Korea Institute of Carbon Convergence Technology) ;
  • Kim, Byung-Joo (R&D Division, Korea Institute of Carbon Convergence Technology)
  • Received : 2015.12.12
  • Accepted : 2016.03.28
  • Published : 2016.07.31

Abstract

In this work, we studied the effects of electrochemical oxidation treatments of carbon fibers (CFs) on interfacial adhesion between CF and epoxy resin with various current densities. The surface morphologies and properties of the CFs before and after electrochemical-oxidation-treatment were characterized using field emission scanning electron microscopy, atomic force microscopy, Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, and single-fiber contact angle. The mechanical interfacial shear strength of the CFs/epoxy matrix composites was investigated by using a micro-bond method. From the results, electrochemical oxidation treatment introduced oxygen functional groups and increased roughness on the fiber surface. The mechanical interfacial adhesion strength also showed higher values than that of an untreated CF-reinforced composite.

Keywords

1. Introduction

Carbon fibers (CFs) have been popularly employed as an important reinforcing material in advanced composites due to their extremely high strength, high specific modulus, heat resistance, and low weight [1]. Because of these advantages, carbon fiber-reinforced plastics (CFRPs) are widely used in the aerospace [2,3], automobile [4,5], and sports industries [6]. Thermoset matrix composites have been of significant importance to the engineering community for many years. Among the available thermoset polymers, epoxy is one of the general plastics produced and consumed in large quantities, because of its strong comprehensive performance and various applications in a wide array of fields [7,8].

It is well known that the interfacial adhesion between the fiber surface and matrix in CFRPs plays an important role for almost all the mechanical properties of the composite. However, CFRPs show poor interfacial adhesion between fibers and epoxy resin, because of the inert surface and low surface energy of the CFs. This leads to poor interfacial adhesion between CFs/epoxy resin, resulting in more defects and low mechanical properties of the composites. Therefore, surface treatment should be introduced into the manufacture process of CFs to improve the interfacial adhesion between CFs and epoxy resin, finally enhancing the mechanical properties of CFRPs [9-12]. To enhance the surface properties and surface functional groups on CFs, various surface treatment methods such as electrochemical oxidation treatment [13,14], ozone oxidation treatment [15,16], plasmas treatment [17,18], and so on have been introduced. Among them, electrochemical oxidation treatment is known to be very effective for enhancing interfacial adhesion and increasing oxygen founctional groups. It is generally preferred because the treatment process is comparatively mild, and it has been widely applied in industrial manufacturing [19,20]. In order to treat the CF surface, various electrolytes have been used such as acid solutions, basic solutions, and ammonium-salt solutions. Among these, ammonium bicarbonate (ABC) is usually chosen not only because it does not cause damage to the equipment, but also because it can eliminate the residues during the heat treatment [21]. Thus, electrochemical oxidation treatment using ABC is widely used in industries to produce CFs.

In order to experimentally measure and assess the interfacial strength of CFRPs, the interfacial shear strength (IFSS) test is important. Generally three techniques have been developed to evaluate the IFSS: the fragmentation test [22,23], pull-out test [24-26], and micro-bond test [27-29]. Among these, the micro-bond test has been one of the most extensively used methods to measure the IFSS between reinforcing fibers and polymers due to the simplicity of sample preparation and IFSS measurement [30,31].

In this work, electrochemical oxidation treatment on CF surfaces was carried out to enhance the interfacial adhesion between CFs and epoxy resin. In order to evaluate the improved interfacial adhesion, the single-fiber contact angle and IFSS measurement of electrochemical oxidation treated CFs were investigated using the Wilhelmy balance method and a micromechanical test.

 

2. Experimental

2.1. Materials

Un-sized polyacrylonitrile-based carbon fibers (48K; A-Company, Jeonju, Korea) were used as a reinforcing material, and ABC (Daejung Chem. Co., Korea) was used in the electrolyte. Epoxy resin (YD-128; Kukdo Chemicals & Metals Co., Siheung, Korea), diglycidylether of bisphenol-A (DGEBA), was used as the main matrix resin, and 4,4'-diaminodiphenol methane (DDM; Tokyo Chemical Industry Co., Ltd., Tokyo, Japan) was used as a curing agent. The ratio of epoxy resin to the curing agent was adjusted to 1 equivalent.

2.2. Electrochemical oxidation treatment of CFs

Electrochemical oxidation treatment was carried out using a laboratory pilot appratus. Oxidation takes place in a continuous process. CFs were treated with different current densities in a range of 1 to 4 A/m2. The concentration of ABC solution, treatment time, and treatment speed were fixed at 0.5 mol, 1.4 min, and 0.7 m/min, respectively. The fibers were first immersed in an ABC solution. After oxidation treatments, the treated CFs were washed with distilled water in order to remove the adsorptive electrolyte on the CF surfaces. The electrochemical-oxidation-treated CFs, denoted as CF-AS, CF-1.0, CF-2.0, CF-3.0, and CF-4.0, were prepared at different current density.

2.3. Sample preparation and IFSS test

To evaluate the interfacial adhesion between electrochemical oxidation treated CFs and epoxy, a sample preparation and debonding process were conducted, as shown in Fig. 1. CFs with minimal damage were carefully selected and placed at the centerline in the middle of a paper frame, and then glued by an epoxy resin. Using a sharp needle, epoxy droplets of approximately 80–150 µm diameter were then placed on the fiber. The epoxy resin was allowed to cure at room conditions for 72 h to reach full strength.

Fig. 1.Schematic of the micro-bond test.

In the traditional microbond test method, two blades are fixed so that a fiber can be pulled out from a droplet of matrix. Several significant parameters, including embedded fiber length, fiber diameter, and the peak pull-out force, are measured. At this moment, assuming that the measured force is equal to a shearing force that is applied to the whole interface and distributed evenly, the IFSS is then calculated using the following eq (1):

where F is the peak pull-out force (N), D is the fiber diameter (µm), and L is the embedded fiber length (µm) in the matrix.

2.4. Measurement of wettability and surface energies

Single-fiber contact angle measurements of electrochemical oxidation treated CFs were carried out using the Wilhelmy balance method. The dynamic contact angle is measured using two solutions, distilled water (γ = 72.8 mN/m, , and , Ström) and diiodomethane (γ = 50.8 mN/m, , and , Donnet). Where γ is the surface tension of the wetting liquide, is the dispersion component of the wetting liquide, and is the polar component of the wetting liquide. By using two testing liquids, the surface free energy of the CFs can be calculated according to the Wilhelmy balance method [32], as described in eq (2):

where F is the measured force, P is the wetted perimeter of the fiber at the liquid/air interface, γ is the surface tension of the wetting liquid, cosθ is the contact angle of the fiber surface, W is the weight of the fiber, ρ is the density of the wetting liquid, g is the gravitational acceleration, y is the immersion depth, and A is the cross-sectional area of the fiber. W is taken prior to measurement, and the buoyancy force is zero at the immersing interface. Therefore, eq (3) can be modified as:

The solid surface tensions of the investigated CFs and epoxy matrix were calculated from the measured contact angle values according to the work of adhesion (Wad). The contact angles of water and diiodomethane on the epoxy matrix were measured using the sessile drop method [33]. Wad can be estimated by applying Fowke’s theory [34] and the Young-Dupré equation [35] according to the geometric mean method, as given in the following eq (4):

where γs is the surface energetic of the CFs listed in Table 1, γL is the surface energetic of the epoxy matrix used and and [36].

2.5. Characterization

The CF surface and microfailure modes of the microdroplet were studied by field emission scanning electron microscopy (SUPRA 40VP; Carl Zeiss, Germany). After applying Os coating, measurements were taken at an acceleration voltage of 2 kV. Surface topographical images were obtained by atomic force microscopy (AFM; Park Systems Corp., Suwon, Korea). In this analysis the tapping mode was employed with a scanning scope of 3 µm. The infrared spectra of the electrochemical oxidaition treated CFs were obtained by Fourier transform infrared spectroscopy (FT-IR; Nicolet iS 10, Thermo, USA) at 4000–500 cm−1 wavelengths. Chemical components and the relative content of functional groups on the CF surface were analyzed through X-ray photoelectron spectroscopy (XPS; PHI 5000 Versa Probe II, ULVAC-PHI; Chigasaki, Japan). The single-fiber contact angle was measured using a Krüss K-100SF (Krüss GmbH Ltd., Hamburg, Germany) with 1 µg weight resolution. A tensile test of the fiber was carried out on a Favigraph semiautomatic device (Textechno Company, Mönchengladbach, Germany). The gauge length of the fiber was 20 mm and the draw-off clamp speed was set at 1 mm/min. A micro-bond test for single-fiber was carried out on a universal material testing machine (Lloyd, UK) with a constant speed of 0.1 mm/min.

 

3. Results and Discussion

3.1. Surface wettability of CFs

Table 1 shows the dispersive and polar components of the surface free energies and the work of adhesion for the untreated and electrochemical oxidation treated CFs. The surface free energy and work of adhesion of the CFs increased after electrochemical oxidation treatment. If the value of the polar component after the treatment is high, many hydrophilic groups such as hydroxyl (-OH), carbonyl (C=O), carboxyl (-COOH), and amine (-NH2) can exist on the fiber surface [37]. Meanwhile, an increase of dispersive components is possible due to the increase of specific surface area due to the roughness change after the treatment. Therefore, from this result it is seen that the surface of the electrochemical-oxidation-treated CFs was significantly changed in terms of both dispersive and polar components, resulting in improvement of the surface adhesion with matrices.

Table 1.CF, carbon fiber; Wad, work of adhesion; γs, surface free energy of the carbon fibers;, dispersion component of the surface free energy;, polar component of the surface free energy.

3.2. Surface properties of CFs

The effects of the electrochemical oxidation treatment on the surface morphology of CFs were analyzed with scanning electron microscopy (SEM) and AFM images. As shown in Fig. 2, the surface of CF-AS showed a characteristic flat topography. After electrochemical oxidation treatment, the surface is uniformly rough with many deep grooves. In addition, after electrochemical oxidation, the value of the root mean square average roughness (Rq) was increased from 50.9 to 90.7 µm. The electrochemical oxidation reaction generally damages the CFs and leads to deep grooves and edges on the CF surface, and this is believed to account for the greater roughness. This increase in surface roughness should be advantageous for mechanical properties of CFPRs because a rough surface would lead to good mechanical interlocking and enhance the interfacial bonding strength between the CFs and epoxy resin.

Fig. 2.Surface analysis of carbon fibers before (CF-AS) and after (CF-4.0) electrochemical oxidation: (a) scheme of surface oxidation, (b) scanning electron microscopy images of the CFs, (c) atomic force microscopy images of the CFs.

Besides enhancing mechanical interlocking between CFs and epoxy resin, electrochemical oxidation treatment introduced oxygen-containing functional groups and thereby increased the surface polarity. Fig. 3 shows the FT-IR spectra of the electrochemical-oxidation-treated CFs as a function of current densities. The oxygen functional groups including -OH (3500 cm−1), C=O (1634 cm−1), and C-O (1082 cm−1) are improved with increasing current density. The -OH or -COOH groups are capable of forming covalent interfacial bonds in the cross-linked polymer adhesive. These bonds couple to the fiber and optimally transfer stresses between the matrix and the fiber, thereby enhancing the interfacial adhesion [38,39]. It is wellknown fact that the increase in oxygen functional group after a surface treatment can lead to the enhancement in mechanical properties [40].

Fig. 3.Fourier transform infrared spectroscopy spectra of the untreated and electrochemical oxidation treated carbon fibers (CFs) as a function of current densities.

XPS survey spectra of the electrochemical-oxidation-treated CFs and analysis results are shown in Fig. 4 and Table 2. Fig. 4a shows the carbon (C1s, BE [binding energy] = 284 eV), oxygen (O1s, BE = 532 eV), and nitrogen (N1s, BE = 400 eV) peaks. It was found that C1s peak decreased with increasing current density, while the O1s peak increased. As can be seen from the XPS sub-peak analysis, the content of oxygen functional groups, such as C-OH (BE = 285.9–286.2 eV), C=O (BE = 287.3–287.6 eV), and COOH (BE = 288.6–288.7 eV), increased with current density. The O1s/C1s ratios and elemental content on the surfaces of CFs by the electrochemical oxidation treatment are shown in Table 2. The increased degree of oxygen content on the CF surface can be confirmed by the O1s/C1s. All treated CFs showed higher oxygen content than that of the CF-AS. This indicates that the electrochemical oxidation treatment effectively introduced a large amount of oxygen containing functional groups. This in turn improves the interfacial adhesion between CFs and epoxy resin in a composite system.

Fig. 4.X-ray photoelectron spectroscopy (XPS) analysis results; (a) XPS survey spectra of the untreated and electrochemical oxidation treated carbon fibers (CFs) as a function of current densities, (b) High resolution before and after electrochemical oxidation treatment.

Table 2.CF, carbon fiber.

3.3. Mechanical properties of CFs

IFSS and tensile strength values of untreated and surface treated CFs are shown in Fig. 5. The tensile strength value of the CFs slightly decreased (86% of original strength) with increasing current densities. This showed that the chemical etching effect on the CF surface in the process of electrochemical oxidation could degrade the mechanical properties of the CFs. In contrast, the IFSS values of the CFs increased (144% enhanced) with increasing current densities. The roughness of the CF surfaces could result in an increase of the surface contact area and enhance the physical bonding between the CFs and epoxy resin, and the increased content of oxygen functional groups could improve the interfacial adhesion between the CFs and epoxy resin, as confirmed by the work of adhesion. Therefore, because of the increase in the amount of oxygen functional groups and the roughness of the CF surface during the electrochemical oxidation treatment process, the mechanical interfacial strength of the CFRPs was dramatically enhanced.

Fig. 5.Interfacial shear strength (IFSS) and tensile strength of the carbon fibers (CFs) before and after the electrochemical oxidation treatment for various current densities.

The trend of the IFSS results is similar to that of the surface free energy (γs). In fact, the correlation of IFSS with γs is almost linear for all samples with different current densities, as shown in Fig. 6. Therefore, γs is one of main factors affecting the adhesion between the fibers and the epoxy matrix.

Fig. 6.Dependence of interfacial shear strength (IFSS) on the γs. R, Pearson correlation coefficient; γs, surface free energy of the carbon fibers.

3.4. Fracture morphological structure after IFSS test

Fig. 7 shows SEM images for the untreated and electrochemical oxidation treated CF/epoxy composites after the micro-bond test for CF-AS and CF-4.0. As shown in the figure, the morphology of the untreated and electrochemicaloxidation-treated sample images differs. In Fig. 7a, no residual epoxy resin in the de-bonding zone was observed for the untreated CFs while a large amount of residual epoxy resin remained in the de-bonding zone for the electrochemicaloxidation-treated CFs. This showed that the electrochemical oxidation treatment on CFs provided better IFSS due to increased surface roughness and the introduction of oxygen functional groups.

Fig. 7.Fractured morphologies of the carbon fiber (CF)/epoxy after interfacial shear strength test: (a) CF-AS, (b) CF-4.0.

 

4. Conclusions

In this study, electrochemical oxidation treatment with different current densities was performed. After electrochemical oxidation treatment, the adhesion strength between CFs and epoxy resin predominantly increased. The electrochemical oxidation on the CF surface improved the IFSS of the composites due to the introduction of oxygen functional groups and an increase in roughness, attributed to the polar and dispersive component on the CF surface, resulting in enhanced interfacial adhesion between the CFs and epoxy resin in this composite system.

References

  1. Diaz A, Guizar-Sicairos M, Poeppel A, Menzel A, Bunk O. Characterization of carbon fibers using X-ray phase nanotomography. Carbon, 67, 98 (2014). http://dx.doi.org/10.1016/j.carbon.2013.09.066.
  2. Yu Q, Chen P, Wang L. Degradation in mechanical and physical properties of carbon fiber/bismaleimide composite subjected to proton irradiation in a space environment. Nucl Instrum Methods Phys Res Sect B: Beam Interact Mater At, 298, 42 (2013). http://dx.doi.org/10.1016/j.nimb.2013.01.007.
  3. Lv M, Zheng F, Wang Q, Wang T, Liang Y. Friction and wear behaviors of carbon and aramid fibers reinforced polyimide composites in simulated space environment. Tribol Int, 92, 246 (2015). http://dx.doi.org/10.1016/j.triboint.2015.06.004.
  4. Yang KS, Kim BH, Yoon SH. Pitch based carbon fibers for automotive body and electrodes. Carbon Lett, 15, 162 (2014). http://dx.doi.org/10.5714/cl.2014.15.3.162.
  5. Jin FL, Park SJ. Preparation and characterization of carbon fiber-reinforcedthermosetting composites: a review. Carbon Lett, 16, 67(2015). http://dx.doi.org/10.5714/cl.2015.16.2.067.
  6. Shin HK, Park M, Kang PH, Choi HS, Park SJ. Preparation and characterization of polyacrylonitrile-based carbon fibers produced by electron beam irradiation pretreatment. J Ind Eng Chem, 20, 3789 (2014). http://dx.doi.org/10.1016/j.jiec.2013.12.080.
  7. Liu Y, Zhang X, Song C, Zhang Y, Fang Y, Yang B, Wang X. An effective surface modification of carbon fiber for improving the interfacial adhesion of polypropylene composites. Mater Des, 88, 810 (2015). http://dx.doi.org/10.1016/j.matdes.2015.09.100.
  8. Zvetkov VL, Djoumaliisky S, Simeonova-Ivanova E. The non-isothermal DSC kinetics of polyethylene tereftalate-epoxy compatible blends. Thermochim Acta, 553, 16, (2013). http://dx.doi.org/10.1016/j.tca.2012.11.026.
  9. Wang C, Ji X, Roy A, Silberschmidt VV, Chen Z. Shear strength and fracture toughness of carbon fibre/epoxy interface: effect of surface treatment. Mater Des, 85, 800 (2015). http://dx.doi.org/10.1016/j.matdes.2015.07.104.
  10. Yuan H, Wang C, Zhang S, Lin X. Effect of surface modification on carbon fiber and its reinforced phenolic matrix composite. Appl Surf Sci, 259, 288 (2012). http://dx.doi.org/10.1016/j.apsusc.2012.07.034.
  11. Han SH, Oh HJ, Lee HC, Kim SS. The effect of post-processing of carbon fibers on the mechanical properties of epoxy-based composites. Compos Part B: Eng, 45, 172 (2013). http://dx.doi.org/10.1016/j.compositesb.2012.05.022.
  12. Zhang G, Sun S, Yang D, Dodelet JP, Sacher E. The surface analytical characterization of carbon fibers functionalized by H2SO4/HNO3 treatment. Carbon, 46, 196 (2008). http://dx.doi.org/10.1016/j.carbon.2007.11.002.
  13. Gulyás J, Földes E, Lázár A, Pukánszky B. Electrochemical oxidation of carbon fibres: surface chemistry and adhesion. Comps Part A: Appl Sci Manuf, 32, 353 (2001). http://dx.doi.org/10.1016/s1359-835x(00)00123-8.
  14. Fukunaga A, Ueda S, Nagumo M. Anodic surface oxidation mechanisms of PAN-based and pitch-based carbon fibres. J Mater Sci, 34, 2851 (1999). http://dx.doi.org/10.1023/a:1004679200908.
  15. Han W, Choi WK, An KH, Kim HG, Kang SJ, Kim BJ. Effects of crack resistance properties of ozone-treated carbon fibers-reinforced nylon-6 matrix composites. Appl Chem Eng, 24, 363(2013).
  16. Park SJ, Kim BJ. Roles of acidic functional groups of carbon fiber surfaces in enhancing interfacial adhesion behavior. Mater Sci Eng: A, 408, 269 (2005). http://dx.doi.org/10.1016/j.msea.2005.08.129.
  17. Park OK, Kim WY, Kim SM, You NH, Jeong Y, Lee HS, Ku BC. Effect of oxygen plasma treatment on the mechanical properties of carbon nanotube fibers. Mater Lett, 156, 17 (2015). http://dx.doi.org/10.1016/j.matlet.2015.04.141.
  18. Lee H, Ohsawa I, Takahashi J. Effect of plasma surface treatment of recycled carbon fiber on carbon fiber-reinforced plastics (CFRP) interfacial properties. Appl Surf Sci, 328, 241 (2015). http://dx.doi.org/10.1016/j.apsusc.2014.12.012.
  19. Liu J, Tian Y, Chen Y, Liang J. Interfacial and mechanical properties of carbon fibers modified by electrochemical oxidation in (NH4HCO3)/(NH4)2C2O4·H2O aqueous compound solution. Appl Surf Sci, 256, 6199 (2010). http://dx.doi.org/10.1016/j.apsusc.2010.03.141.
  20. Li Z, Wang J, Tong Y, Xu L. Anodic oxidation on structural evolution and tensile properties of polyacrylonitrile based carbon fibers with different surface morphology. J Mater Sci Technol, 28, 1123(2012). http://dx.doi.org/10.1016/s1005-0302(12)60181-9.
  21. Qian X, Wang X, Ouyang Q, Chen Y, Yan Q. Effect of ammonium-salt solutions on the surface properties of carbon fibers in electrochemical anodic oxidation. Appl Surf Sci, 259, 238 (2012). http://dx.doi.org/10.1016/j.apsusc.2012.07.025.
  22. Tripathi D, Jones FR. Single fibre fragmentation test for assessing adhesion in fibre reinforced composites. J Mater Sci, 33, 1 (1998).
  23. Zhao FM, Takeda N. Effect of interfacial adhesion and statistical fiber strength on tensile strength of unidirectional glass fiber/epoxy composites. Part Ι: experiment results. Compos Part A: Appl Sci Manuf, 31, 1203 (2000). http://dx.doi.org/10.1016/s1359-835x(00)00085-3.
  24. Zhandarov S, Mäder E. Characterization of fiber/matrix interface strength: applicability of different test, approaches and parameters. Compos Sci Technol, 65, 149 (2005). http://dx.doi.org/10.1016/j.compscitech.2004.07.003.
  25. Tsuda T, Ogasawara T, Deng F, Takeda N. Direct measurements of interfacial shear strength of multi-walled carbon nanotube/PEEK composite using a nano-pullout method. Compos Sci Technol, 71, 1295 (2011). http://dx.doi.org/10.1016/j.compscitech.2011.04.014.
  26. Domnanovich A, Peterlik H, Kromp K. Determination of interface parameters for carbon/carbon composites by the fibre-bundle pull-out test. Compos Sci Technol, 56, 1017 (1996). http://dx.doi.org/10.1016/0266-3538(96)00060-7.
  27. Zhandarov S, Mäder E. An alternative method of determining the local interfacial shear strength from force-displacement curves in the pull-out and microbond test. Int J Adhes Adhes, 55, 37 (2014). http://dx.doi.org/10.1016/j.ijadhadh.2014.07.006.
  28. Miller B, Muri P, Rebenfeld L. A microbond method for determination of the shear strength of a fiber/resin interface. Comps Sci Technol, 28, 17 (1987). http://dx.doi.org/10.1016/0266-3538(87)90059-5.
  29. Liu WB, Zhang S, Hao LF, Jiao WC, Yang F, Li XF, Wang RG. Properties of carbon fiber sized with poly(phthalazinone ether ketone) resin. J Appl Polym Sci, 128, 3702 (2013). http://dx.doi.org/10.1002/app.38605.
  30. Wang H, Wang H, Li W, Ren D, Yu Y. An improved microbond test method for determination of the interfacial shear strength between carbon fibers and epoxy resin. Polym Test, 32, 1460 (2013). http://dx.doi.org/10.1016/j.polymertesting.2013.09.017.
  31. Liu B, Liu Z, Wang X, Zhang G, Long S, Yang J. Interfacial shear strength of carbon fiber reinforced polyphenylene sulfide measured by the microbond test. Polym Test, 32, 724 (2013). http://dx.doi.org/10.1016/j.polymertesting.2013.03.020.
  32. Wilhelmy L. Ueber die Abhängigkeit der Capillaritäts-Constanten des Alkohols von Substanz und Gestalt des benetzten festen Körpers. Annalen der Physik und Chemie, 195, 177 (1863). http://dx.doi.org/10.1002/andp.18631950602.
  33. Habal A, Singh D. Comparison of Wilhelmy plate and Sessile drop methods to rank moisture damage susceptibility of asphalt: aggregates combinations. Constr Build Mater, 113, 351 (2016). http://dx.doi.org/10.1016/j.conbuildmat.2016.03.060.
  34. Fowkes FM. Attractive forces at interfaces. Ind Eng Chem, 56, 40 (1964). http://dx.doi.org/10.1021/ie50660a008.
  35. Barraza HJ, Hwa MJ, Blakley K, O'Rear EA, Grady BP. Wetting behavior of elastomer-modified glass fibers. Langmuir, 17, 5288(2001). http://dx.doi.org/10.1021/la010207l.
  36. Kim HI, Choi WK, Oh SY, Seo MK, Park SJ, An KH, Lee YS, Kim BJ. Effects of oxyfluorination on surface and mechanical properties of carbon fiber-reinforced polarized-polypropylene matrix composites. J Nanosci Nanotechnol, 14, 9097 (2014). http://dx.doi.org/10.1166/jnn.2014.10095.
  37. Park JM, Kim DS, Kong JW, Kim M, Kim W, Park IS. Interfacial adhesion and microfailure modes of electrodeposited carbon fiber/epoxy-PEI composites by microdroplet and surface wettabilitytests. J Colloid Interface Sci, 249, 62 (2002). http://dx.doi.org/10.1006/jcis.2002.8252.
  38. Zhu J, Kim J, Peng H, Margrave JL, Khabashesku VN, Barrera EV. Improving the dispersion and integration of single-walled carbon nanotubes in epoxy composites through functionalization. Nano Lett, 3, 1107 (2003). http://dx.doi.org/10.1021/nl0342489.
  39. Liu Z, Jones FR, Zhai Z, Feng L. Interfacial adhesion of polyamide 66 fibres to an aqueous polyurethane-acrylic hybrid polymer adhesive. J Adhes, 90, 310 (2014). http://dx.doi.org/10.1080/00218464.2013.795115.
  40. Choi WK, Kim HI, Kang SJ, Lee YS, Han JH, Kim BJ. Mechanical interfacial adhesion of carbon fibers-reinforced polarized-polypropylene matrix composites: effects of silane coupling agents. Carbon Lett, 17, 79 (2016). http://dx.doi.org/10.5714/cl.2016.17.1.079.

Cited by

  1. Next generation high-performance carbon fiber thermoplastic composites based on polyaryletherketones vol.134, pp.6, 2017, https://doi.org/10.1002/app.44441
  2. Studies on Preparation and Characterization of Aluminum Nitride-Coated Carbon Fibers and Thermal Conductivity of Epoxy Matrix Composites vol.7, pp.8, 2017, https://doi.org/10.3390/coatings7080121
  3. Effects of Biceramic AlN-SiC Microparticles on the Thermal Properties of Paraffin for Thermal Energy Storage vol.2018, pp.1687-4129, 2018, https://doi.org/10.1155/2018/8632350