When the queue length of congestion vehicles in tunnel fire is extended beyond tunnel length, the capacity of smoke control system needs to be increased in line with ventilation resistance. However, the vehicle queue length is not defined, so a rational equation is necessary in current fire prevention guideline. This study is intended to propose an equation to calculate the queue length considering the number of vehicles in queue in tunnel fire and evaluate the applicability by tunnel length as well. When it comes to normal tunnel, it is necessary to compare the vehicle queue length with tunnel length up to the length of 1,200 m in a bid to avoid applying the vehicle queue length excessively in case of fire. As a result of evaluation of applicability to model a tunnel, saving the number of jet fan for smoke control appeared to be effective. Besides, quantitative approach to explain the vehicle queue length through the relationship between the percentage of large vehicles and tunnel length was presented. Consequently, when the queue length of the congestion vehicles exceeds the tunnel length in determining the capacity of smoke control system in case of fire, the number of vehicles beyond the tunnel length needs to be excluded from estimating the ventilation resistance by vehicles.
터널 화재시 정체차량에 의한 정체길이가 터널연장을 초과할 경우, 환기저항의 증가에 따른 제연설비 용량의 증가가 발생하게 된다. 그러나 현행 방재지침에는 정체길이에 대한 정의가 없기 때문에 합리적 산출식의 제시가 필요하다. 본 연구에서는 터널 화재시 정체차량 대수에 의한 정체길이의 산정식을 제시하고, 터널연장별 적용성 분석을 수행하였다. 일반적인 터널의 경우, 화재시 정체길이의 과도한 적용을 방지하기 위해서는 터널연장 1,200 m 까지는 정체길이와 터널연장과의 상호비교가 필요한 것으로 분석되었고, 모델터널에 대한 적용성 평가결과 제연용 제트팬의 절감효과가 있는 것으로 분석되었다. 더불어 정체길이의 판별여부를 대형차혼입률과 터널연장의 관계로 설명할 수 있는 정량화 선도를 제시하였다. 결과적으로 제연설비 용량결정시, 정체차량에 의한 정체길이가 터널연장을 초과하는 경우에는 터널연장을 초과하는 차량대수는 차량에 의한 환기저항 산정에서 제외하는 것이 타당한 것으로 분석된다.