After an earthquake occurred in the Gyeongju, 2016, many low-story buildings have been questioned in terms of the seismic performance since mostly they have been exempted from the seismic design requirement since 1988. In this study, a 3-story moment resisting frame (MRF) building was analyzed and evaluated the seismic performance. Due to the insufficient seismic performance required for the seismic performance levels, three different seismic retrofit schemes were proposed and their seismic performances were re-evaluated. While steel brace and open shear wall retrofit systems mainly focused on the strength retrofit, the VES damper retrofit system is mainly to enhance the energy dissipation capacity of the system and resultes in the increased ductility. The original building and 3 retrofitted buildings were evaluated using the nonlinear static and nonlinear dynamic analyses and suggestions were proposed. Through the analysis of nonlinear time history and push-over using MIDAS/Gen program, damages of the building in terms of top story and average story drift and effect of reinforcement were analyzed.

Keywords

References

  1. Architectural Institute of Korea. Architectural Structure Design Standards and Commentary. c2009.
  2. Architectural Institute of Korea. Architectural Structure Design Standards and Commentary. c2016.
  3. Federal Emergency Management Agency, FEMA-P965. Quantification of Building Seismic Performance Factors. FEMA. c2009.
  4. Ministry of Land, Transport and Maritime Affairs. Seismic Performance Evaluation Method of Existing Structures. c2011.
  5. Korean Educational Development Institute. Seismic Performance Evaluation and Seismic Retrofit Guidelines for School Structures. c2011.
  6. Ministry of Construction & Transportation, Seismic Design Criteria Research(II). c1997.
  7. Kim DH, Lee DK, Lee KH. Journal of the Korean Association for Spatial Structures, Vol. 15, No. 2. Structural Performance Evaluation of VES Damper System subjected to Cyclic Loadings (CST30). c2015.
  8. Ahn CW, Yoon JH, Song DY, Shang BS, Min CG. EESK J Earthquake Eng. 17(6):293-303, The design considerations of steel braced frame for seismic retrofit through increasing the lateral strength of existing RC buildings. c2013.
  9. Yi YS, Hong SG. Journal of the Korea Concrete Institute. Seismic Performance Evaluation of Shear Wall Retrofitted with FRP. c2013.
  10. National Emergency Management Agency. Guidelines for evaluation of seismic performance of buildings. c2012.
  11. Hong Juhee. Seismic performance evaluation of MRF building structures retrofitted using VES30 damper systems. Sejong University, c2016.
  12. Seismic evaluation and retrofit of concrete buildings. ATC-40.
  13. Prestandard and Comnmentary for the seismic rehabilitation of buildings(FEMA 356).