DOI QR코드

DOI QR Code

PM10 Emission Estimation from LNG G/T Power Plants and Its Important Analysis on Air Quality in Incheon Area

인천 지역 LNG G/T발전소의 미세먼지 (PM10) 배출량 평가 및 주변 대기질 영향 분석

  • Gong, Bu-Ju (National Institute of Environmental Research) ;
  • Park, Poong-Mo (Department of Environmental Engineering, University of Seoul) ;
  • Dong, Jong-In (Department of Environmental Engineering, University of Seoul)
  • Received : 2015.08.27
  • Accepted : 2015.09.24
  • Published : 2015.10.31

Abstract

Base on emission factors derived from National Institute of Environmental Research, Particulate matter from combined cycle power plants (CCPPs) has been estimated to be a important source of $PM_{10}$. Generally there is no serious emission of particulate matter in CCPPs. because the fuel of them is natural gas. But emission gas after long shut down season has very high dust content. Therefore $PM_{10}$ emission rate is dependent on its operation mode. In this study, particulate dispersion study for new city near CCPPs complex has performed using CALPUFF model for three case. $PM_{10}$ concentration has big difference between normal operation and 2 case start-up condition after long shutdown. In normal operating conditions, daily $0.32{\sim}0.50{\mu}g/m^3$ influence on of the surrounding area. But when 1~2 aerobic high concentration discharged conditions, average concentration is higher about $9.2{\sim}34.1{\mu}g/m^3$ than normal operating conditions.

Keywords

References

  1. Craig, B. (2005) Identify, correct HRSG gas-side corrosion problems, Combined Cycle Journal, Third Quarter, OH14-OH16.
  2. Korea Electric Power Corporation (KEPC) (2015) The Monthly Report on Major Electric Power Statistics, KEPC, Official Press Release No. 2015-08468126-Jeong 0099.
  3. Korea Institute of Energy Technology Evaluation and Planning (2011) KETEP Issue paper-Status of domestic and foreign on Gas Turbine Tech., (3), 3-7.
  4. Malik, A.U., S.A. Al-Fozan, M. Mobin, and M. Al-Hajri (2013) Studies on the Failure of Economizer Tubes Involving Acid Dew-Point Corrosion in High Pressure Boilers, Intl. J. of Sci. & Eng. Research, 4(9), 1726-1736.
  5. National Institute of Environmental Research (NIER) (2010) National Air Pollutant Emission Calculation Method Manual (II), NIER Official Press Release No. 11-1480523-000189-01.
  6. National Institute of Environmental Research (NIER) (2013) National Air Pollutant Emission Calculation Method Manual (III), NIER Official Press Release No. 11-1480523-001501-01.
  7. National Institute of Environmental Research (NIER) (2014) Metropolitan landfill odor monitoring research (II), NIER Official Press Release No. 11-1480523-002016-01.
  8. US EPA (2007) Guidance on the Use of Models and Other Analyses for Demonstrating Attainment of Air Quality Goals for Ozone, $PM_{2.5}$, and Regional Haze, EPA-454/B-07-02. Power Industry News, 2014.
  9. Usami, A., T. Noguchi, H. Tezuka, S. Nishimura, and T. Kusunoki (2003) Development of a Water Dew Corrosion Resistant New Steel Element for Air Preheaters at Natural Gas Fired Power Plants, NIPPON STEEL TECHNICAL REPORT No. 87, 10-13.