Abstract
In the fabrication of electronic circuits used in electronic products, molybdenum thin films are deposited on semiconductors to prevent oxidation. During the deposition, the presence of a particle or dust at the interface between the thin film and substrate causes the decrease of adhesion, performance, and life cycle. In this study, a damage measurement targeting two kinds of glass substrate, with and without particles, was performed in order to measure the change in the molybdenum thin film deposition area in the presence of a particle. Clean and dirty molybdenum thin film specimens were fabricated and directly deposited on a substrate using the sputtering method, and a reflection-type digital holographic interferometer was configured for measuring the damage. Reflection-type digital holography has several advantages; e.g., the configuration of the interferometer is simple, the measurement range can be varied depending on the magnification of a microscopic lens, and the measuring time is short. The results confirm that reflection-type digital holography is useful for the measurement of the damage and defects of thin films.
전자제품에 필수적으로 사용되는 전자회로의 제작 시, 반도체 위에 증착하는 박막의 산화를 방지하기 위하여 molybdenum을 증착한다. Molybdenum 박막 증착 시 표면의 particle 또는 dust의 존재는 밀착력 감소 및 성능 저하, 수명 단축, 안전도 저하를 유발한다. 본 논문에서는 particle의 유무에 따른 molybdenum 박막 증착부의 변화를 보기 위하여, 두 가지 glass substrate를 대상으로 손상 측정 실험을 하였다. Sputtering 증착 기법으로 molybdenum이 glass substrate에 직접 코팅이 되는 clean과 dirty 두 종류의 molybdenum 박막을 제작하고, 손상 측정을 위해 반사형 디지털 홀로그래피를 구성하였다. 반사형 디지털 홀로그래피는 간섭계의 구성이 손쉽고 다양한 배율렌즈를 적용하여 측정영역에 다양성을 줄 수 있으며, 측정시간이 타 기법에 비해 짧다는 장점을 가진다. 실험 결과로부터 반사형 디지털 홀로그래피가 박막의 손상 및 결함 측정에 유용한 기술임을 확인하였다.