DOI QR코드

DOI QR Code

The Study on Predicting Method for Evaluating Structural Safety of a School under Fire

화재상황에서의 학교건축물 구조안전성 변화 예측 기법 연구

  • Received : 2015.01.07
  • Accepted : 2015.08.17
  • Published : 2015.08.30

Abstract

The purpose of this study was to find variables effecting on fire simulation and to evaluate safety of the structural members based on temperature distributions. Toward that goal, fire simulation, transient heat transfer analysis, structural safety evaluation are carried out sequentially using Fire Dynamics Simulator (FDS), ABAQUS 6.10-3, MIDAS 785, respectively. Fire simulation is performed on a 5-story building used for a school, located in Seoul, South Korea. The results of this study were as follows; structural members are exposed spatially non-uniform temperatures which can cause significant eccentric deformation and acceleration of structural damages. Using non-uniform temperatures, reduction ratios of structural performance in structural members are deducted.

Keywords

Acknowledgement

Supported by : 한국연구재단

References

  1. An, A. Y., Ryu, E. M., & Kim, H. S. (2014). Investigations on structural safety of office room based on fire simulation and transient heat transfer analysis, World Journal of Engineering and Technology, 2, 20-26 https://doi.org/10.4236/wjet.2014.23B004
  2. Andrew H. Buchanan (2001). Structural Design for Fire Safety, JOHN WILEY & SONS, STD, 130
  3. Au, S. K., Wang, Z., & Lo, S. (2007). Compartment fire risk analysis by advanced Monte Carlo simulation, Engineering Structures, 29, 2834-2835
  4. Bjorn Karlsson, James G. Quintiere (2000). Enclosure Fire Dynamics, CRC Press LLC 2000 N.W. Corporate Blvd., Boca Raton, Florida 33431
  5. Choi, E. G. (2008). Performance assessment of high strength concrete members subjected to fire, Ph.D. thesis, Ewha Womans University
  6. Choi, J. H. (2008). Concurrent Fire Dynamics Models and Thermomechanical Analysis of Steel and Concrete Structures, Ph.D. Thesis, Georgia Institute of Technology
  7. Choi, J. H., Haj-Ali, R. M., & Kim H. S. (2012). Integrated fire dynamic and thermomechanical modeling of a bridge under fire. Structural Engineering and Mechanics, 42
  8. Choi, J. H., Kim, H. S., & Haj-Ali, R. M. (2010). Integrated fire dynamic and thermomechanical modeling framework for steel-concrete composite structures. Steel and Composite Structures, 10, 129-135 https://doi.org/10.12989/scs.2010.10.2.129
  9. Chow, A. U. (2012). Concerns on estimating heat release rate of design fires in fire engineering approach, International Journal on Engineering Performance-Based Fire Codes, 11
  10. Eurocode 2 (2004). Design of concrete structures, Part 1-2: General rules-Structural fire design. BS EN 1992-1-2
  11. Harmathy, T. Z. (1983). Properties of building materials at elevated temperatures, Division of Building Research, 1080
  12. Harmathy, T. Z. (1988). Properties of building materials in SFPE Handbook of fire protection engineering, Ed. Dinenno, 1
  13. Karlsson, B., & Quintiere, J. G. (2000). Enclosure Fire Dynamics, CRC Press
  14. Kim, H. S., Mun, J. Y., Park, J. S., & Shin, Y. S. (2011). Structural capacity evaluation of high strength concrete short columns with various design parameters under high temperatures, Journal of the Korea Concrete Institute, 23(5), 637-645 https://doi.org/10.4334/JKCI.2011.23.5.637
  15. McGrattan, K., Hostikka, S., Floyd, J., Baum, H., Rehm, R. Mell, W., & McDermott, R. (2010). Fire Dynamics Simulator (Version 5) Technical Reference Guide, National Institute of Standards and Technology (NIST), 1, 45-53
  16. McGrattan, K., & McDermott, R. (2010). Fire Dynamics Simulator (version 5)-User's Guide, National Institute of Standards and Technology (NIST), 23-26
  17. Madrzykowski, D. (1996). Office Work station Heat Release Rate Study; Full Scale vs. Bench Scale, Interflam. Proceedings of 7th International Interflam Conference, 52
  18. Shin, Y. S., Park, J. S., Mun, J. Y., & Kim, H. S. (2011). Experimental studies on the effect of various design parameters on thermal behaviors of high strength concrete columns under high temperatures, Journal of the Korea Concrete Institute, 23(3), 377-379 https://doi.org/10.4334/JKCI.2011.23.3.377