DOI QR코드

DOI QR Code

Analysis on Characteristics and Related Factors of Indoor Air Quality in Newly Built Wooden Houses

신축목조주택의 실내공기질 특성 및 관련요인 분석

  • 최윤정 (충북대학교 주거환경학과) ;
  • 이재경 (충북대학교 주거환경학과) ;
  • 차예랑 (충북대학교 주거환경학과)
  • Received : 2015.03.27
  • Accepted : 2015.08.13
  • Published : 2015.08.25

Abstract

The purpose of this research is to analyze characteristics and related factors of IAQ (Indoor Air Quality) in newly built wooden houses by measuring pre and post occupancy. The subjects were five wooden houses which were built with similar materials and completed from July to December 2013. Measuring factors were TVOC, HCHO, PM10, $CO_2$, CO, indoor temperature, and relative humidity. As the result of pre occupancy measuring, the houses that revealed the lowest TVOC concentration or HCHO concentration were satisfied with "the standard for newly built apartment houses". Therefore, IAQ by the wooden structures is considered to be in good condition. However, in cases of partial value exceeded the standard, the reason is analyzed to be the materials of molding, wrapping doors, built-in closet, or kitchen furniture, etc. rather than structure materials. Most PM10 concentration level showed slightly below "the standard for occupied multi-use facilities". Remaining of construction dust was considered to be the reason. As the result of post occupancy measuring, every value except of one subject's TVOC concentration was lower than pre occupancy, explaining the importance of natural ventilation.

Keywords

References

  1. Cho, J. H., & Choi, Y. J. (2013). The Indoor Thermal and Air Environment of General Apartment Houses during Winter in Cheongju City. Journal of the Korea Institute of Ecological Architecture & Environment, 13(3), 111-120.
  2. Cho, K. H., & Yoon, J. O. (2010). Airtightness and Insulation Performance for Test House with Wood Frame. Proceeding of Spring Annual Conference of Korea Institute of Ecological Architecture and Environment, 15-18.
  3. Ko, Y. S. (2012). A Study on the Indoor Thermal Environment of Newly Built Wooden House in Summer Season. Proceeding of Autumn Annual Conference of Architectural Institute of Korea, 32(2), 299-300.
  4. Lee, H. Y., Park, S. B., Lee, S. M., & Park, J. Y. (2007). The Comparison for Emission Characteristics of Volatile Organic Compounds by Finished Materials in Newly Built Wooden House. Proceeding of Spring Annual Conference of Korea Furniture Society, 100-103.
  5. Lee, S. J., Koo, B. K., Lim, J. H., & Song, S. Y. (2012). Suggestions on the Improvement Scheme of Insulation Regulation through Thermal Performance Evaluation on the Exterior Wall in Wooden or Steel Structure. Proceeding of Autumn Annual Conference of Architectural Institute of Korea, 32(2), 369-370.
  6. Yoon, C. S. & Choi, Y. J. (2014). Housing and Environment. Revised edition. Seoul: Kyomunsa.
  7. Yu, S. G., Kim, S. H., Seo J. K., & Kim, S. M. (2013). Analysis of Energy Efficiency of Light-Weigh Wood Frame House and Wooden Passive House Using PHPP. Journal of the Architectural Institute of Korea Planning & Design, 29(8), 199-207. https://doi.org/10.5659/JAIK_PD.2013.29.8.199
  8. Korea Wood Construction Association. www.kwca.co.kr