• Title/Summary/Keyword: 실내공기질

Search Result 436, Processing Time 0.029 seconds

An Exploratory Research on Social Workers' Attitude and Related Factors about Indoor Air Quality Management of Social Welfare Facilities (사회복지시설 종사자의 실내공기질 관리에 대한 태도와 관련 요인에 관한 탐색적 연구)

  • Bae, Jin-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.5
    • /
    • pp.273-284
    • /
    • 2017
  • As these days people spend most of time at inner space, indoor air quality affect human life seriously. Government manage indoor air quality of various facilities based on different laws. Government released that they would try to protect environment for vulnerable people such children and seniors from indoor air pollutants in 2015. But social welfare facilities are exception under current legal systems. Clients of social welfare residential facilities are the disables, the elderly, homeless and children and they usually stay inner space very long time. The purpose of this study is explore workers' attitude and related factors about indoor air quality management of social welfare facilities. 69.5% of respondents agree to government's indoor air quality management, 80.9% of respondents think social welfare facilities must be included in legal system for indoor air quality management. Environmental awareness and law awareness were related with attitude to indoor air quality management. Based on the results of the analysis, I propose the amendment of law on indoor air quality of the Ministry of Environment, cost burden of central or local government and the necessity of education and research on indoor air quality management in social welfare facilities.

Indoor Air Quality in daycare facilities (보육시설의 실내공기질 유지관리 실태)

  • Park, Jun-Seok
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.21 no.6
    • /
    • pp.28-32
    • /
    • 2014
  • 본 투고에서는 2008년 환경부의 용역으로 실시된 "보육시설의 실내공기질 진단 및 개선 시범사업"의 결과를 바탕으로 우리나라 보육시설의 실내공기 오염 실태와 함께 개선방안, 그리고 개선효과에 대하여 소개하였다. 서울, 경기, 인천 지역의 61개 시설을 대상으로 실내공기질 측정과 설문조사를 실시한 결과 폼알데하이드와 총 휘발성유기화합물은 일부시설에서 "다중이용시설 등의 실내공기질 관리법" 기준치를 초과하는 것으로 나타났다. 반면 이산화탄소와 미세먼지는 조사 대상 시설 중 50 % 이상이 기준치를 초과하는 것으로 나타났다. 따라서 보육시설의 실내공기질 개선을 위해서는 각 오염물질의 발생원별로 유지관리 대책이 필요한 것으로 조사되었다. 또한 오염원인별 분석결과, 대부분 시설의 실외오염물질 농도가 실내보다 낮게 나타나 외기의 오염이 실내에 미치는 영향은 미비한 것으로 나타났으며, 계절에 따른 실내공기오염은 동절기에 낮은 외기온도로 인하여 실내를 하기 때문에 하절기에 비해 더 높게 나타났다. 공간에 따른 오염물질의 농도는 이산화탄소와 미세먼지의 경우 아동이 늘 상주하는 교실의 오염이 가장 심한 것으로 나타났으며 폼알데하이드와 총휘발성유기화합물의 경우 놀이실의 오염도가 교실에 비해 더 높게 나타났다. 개선방안별 개선효과에 있어서는 환기계획 몇 환기설비 설치, 지하공간 습기 문제 개선에서 가장 높은 효과가 나타났다. 향후 보육시설의 쾌적하고 건겅한 실내환경의 유지관리를 위해서는 보육종사자들이 활용할 수 있는 유지관리 지침 또는 매누얼에 대한 보급이 필요할 것으로 판단된다.

실내공기질 오염 저감을 위한 나노-환경기술

  • 최재훈;김현중;이영규;정현석;홍국선
    • Polymer Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.191-197
    • /
    • 2004
  • 실내 환경 (indoor environment)에 대한 관심은 1990년대 이후 급격한 산업구조의 발달을 통한 에너지 소비가 급증하여 환경오염이 가중되면서 본격적으로 대두되었다고 할 수 있다. 실내 환경문제의 대표적인 실내공기질 (Indoor Air Quality, IAQ)에 대한 문제의 발생배경을 보면 1970년대 이후 각종 산업분야에서 에너지 절감 및 효율을 높이기 위한 노력의 일환으로 건물의 열효율을 위한 밀폐화 및 고기밀화에 따른 실내공간의 변화에 따라 이들 건물의 실내공기질이 악화되면서 발생되었다.(중략)

  • PDF

A Study on the Brand Service Design for Measuring and Managing Indoor Air Quality (실내공기질 측정 및 관리를 위한 브랜드 서비스디자인 연구)

  • Kim, Seung-Beom;Kim, Hwoi-Kwang
    • Journal of Digital Convergence
    • /
    • v.16 no.6
    • /
    • pp.325-333
    • /
    • 2018
  • The quality of indoor air quality is facing a very serious situation due to the impact of the quality of the atmosphere in the atmosphere and the surrounding environment. While awareness of the danger of these populations is increasing, there is no way to detect the quality of the indoor air quality as well as the measures to detect the quality of indoor air quality as well as the countermeasures. The study drew a general problem with the design of the service design, the general purpose of the general office, and the use of the public facilities for the purpose of measuring the usage of indoor air quality, the general purpose of public facilities, and the interpretation of the current law. Based on this research, most of the general users' perception of the seriousness of the disease is not reflected in the perception that the dust and indoor air are accumulated in the eyes of the general public.

실내공기질 공정시험방법

  • 이윤규
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.1
    • /
    • pp.11-21
    • /
    • 2004
  • 실내공기질 공정시험법의 개요와 향후 연구진행 방향, 국내외의 실내공기오염물질에 대한 측정 규격의 종류 및 특성, 공정시험법 도출을 위한 기본적인 고려사항 등에 대하여 간단히 살펴보고자 한다.

  • PDF

A Prediction of $CO_2$ Concentration and Measurement of Indoor Air Quality in the EMU (전동차 실내공기질 측정 및 $CO_2$ 농도 예측)

  • So, Jin-Sub;Yoo, Seong-Yeon
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.4
    • /
    • pp.378-383
    • /
    • 2008
  • In December 2006, the Ministry of Environment Republic of Korea established the guideline which is "Indoor Air Quality Management Guidelines in Public Transportation." as control items, $CO_2$ (carbon dioxide) and PM10 (particle matter) are classified two categories, that is, Level 1 (non-rush hour), Level 2 (rush hour). Therefore, the quality of air in train and subway should be controlled in accordance with the guideline. We took a measure the air freshness inside train twice at Line 4 (Tangogae-Oido), in Sep. 2007 and at Line 1 (Dongincheon-Yongsan) in Nov. 2007, respectively and, also expected the emitted $CO_2$ concentration by using a property of matter such as EMU (Electric Multiple Unit) design reviewing specification and air. According to the measured values, the concentration of PM10 was 44, 57, 45% and the concentration of $CO_2$ was 39, 36, 44% respectively, all measured values are within the guideline and also, as a result we found the expected value and measured value are similar.