References
- Al-Abidi K, Ellakwa A. The effect of adding a stone base on the accuracy of working casts using different types of dental stone. J Contemp Dent Pract 2006;7:17-28.
- Anusavice KJ. Phillip's science of dental material. 11th ed. Philadelphia; WB Saunders; 2003. p. 621-54.
- ISO 6873. Dental gypsum products. International Organization for Standardization. 3rd ed. Geneva; Switzerland, 2013.
- Retrieved April 12, 2014, Available from http://en.zhermack.com/ImagePub.aspx?id=120081.pdf.
- Kim KB, Kim JH, Kim WC, Kim HY, Kim JH. Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and three-dimensional replica techniques. J Adv Prosthodont 2013;5:179-86. https://doi.org/10.4047/jap.2013.5.2.179
- American Dental Association. Specification No. 25 for dental gypsum products. In: Certification program for dental materials. Chicago; American Dental Association; 1990. p. 1-14.
- Millstein PL. Determining the accuracy of gypsum casts made from type IV dental stone. J Oral Rehabil 1992;19:239-43. https://doi.org/10.1111/j.1365-2842.1992.tb01098.x
- Duke P, Moore BK, Haug SP, Andres CJ. Study of the physical properties of type IV gypsum, resin-containing, and epoxy die materials. J Prosthet Dent 2000;83:466-73. https://doi.org/10.1016/S0022-3913(00)70043-6
- Kim JH, Kim KB, Kim WC, Kim JH, Kim HY. Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique. Korean J Orthod 2014;44:69-76. https://doi.org/10.4041/kjod.2014.44.2.69
- Linke BA, Nicholls JI, Faucher RR. Distortion analysis of stone casts made from impression materials. J Prosthet Dent 1985;54:794-802. https://doi.org/10.1016/0022-3913(85)90473-1
- DeLong R, Pintado MR, Ko CC, Hodges JS, Douglas WH. Factors influencing optical 3D scanning of vinyl polysiloxane impression materials. J Prosthodont 2001;10:78-85. https://doi.org/10.1111/j.1532-849X.2001.00078.x
- Rodriguez JM, Curtis RV, Bartlett DW. Surface roughness of impression materials and dental stones scanned by non-contacting laser profilometry. Dent Mater 2009;25:500-5. https://doi.org/10.1016/j.dental.2008.10.003
- Beuer F, Aggstaller H, Edelhoff D, Gernet W, Sorensen J. Marginal and internal fits of fixed dental prostheses zirconia retainers. Dent Mater 2009;25:94-102. https://doi.org/10.1016/j.dental.2008.04.018
- Kokubo Y, Nagayama Y, Tsumita M, Ohkubo C, Fukushima S, Vult von Steyern P. Clinical marginal and internal gaps of In-Ceram crowns fabricated using the GN-I system. J Oral Rehabil 2005;32:753-8. https://doi.org/10.1111/j.1365-2842.2005.01506.x
- Williams GJ, Wild S, Bates JF. A study of some factors affecting the surface properties of dental stone. Br Dent J 1984;156:46-53. https://doi.org/10.1038/sj.bdj.4805269
- Keuter FM, Davidson CL. Surface roughness of dental stone casts from alginate impressions. J Dent 1986;14:23-8. https://doi.org/10.1016/0300-5712(86)90098-9
- Nanami T, Ostlund SG. Surface texture of stone model setting against elastomer impression materials. Swed Dent J 1984;8:251-5.
- Ender A, Mehl A. Influence of scanning strategies on the accuracy of digital intraoral scanning systems. Int J Comput Dent 2013;16:11-21.
- Karl M, Graef F, Schubinski P, Taylor T. Effect of intraoral scanning on the passivity of fit of implant-supported fixed dental prostheses. Quintessence Int 2012;43:555-62.
- Luthardt RG, Sandkuhl O, Herold V, Walter MH. Accuracy of mechanical digitizing with a CAD/CAM system for fixed restorations. Int J Prosthodont 2001;14:146-51.
- Reports of councils and bureaus: Revised American National Standards Institute/American Dental Association Specification No. 8 for zinc phosphate cement. J Am Dent Assoc 1978;96:121-3. https://doi.org/10.14219/jada.archive.1978.0032
- Sorensen SE, Larsen IB, Jorgensen KD. Gingival and alveolar bone reaction to marginal fit of subgingival crown margins. Scand J Dent Res 1986;94:109-14.
- McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J 1971;131:107-11. https://doi.org/10.1038/sj.bdj.4802708
- Jorgensen KD, Esbensen AL. The relationship between the film thickness of zinc phosphate cement and the retention of veneer crowns. Acta Odontol Scand 1968;26:169-75. https://doi.org/10.3109/00016356809026130
- Passon C, Lambert RH, Lambert RL, Newman S. The effect of multiple layers of die-spacer on crown retention. Oper Dent 1992;17:42-9.
- Persson AS, Andersson M, Oden A, Sandborgh-Englund G. Computer aided analysis of digitized dental stone replicas by dental CAD/CAM technology. Dent Mater 2008;24:1123-30. https://doi.org/10.1016/j.dental.2008.01.008
Cited by
- Surface Quality of 3D-Printed Models as a Function of Various Printing Parameters vol.12, pp.12, 2015, https://doi.org/10.3390/ma12121970
- Effect of Die Materials on Marginal and Internal Adaptation of Zirconia Copings: An In Vitro Study vol.15, pp.1, 2015, https://doi.org/10.2174/1874210602115010708