References
- Raigrodski AJ, Chiche GJ, Potiket N, Hochstedler JL, Mohamed SE, Billiot S, Mercante DE. The efficacy of posterior threeunit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study. J Prosthet Dent 2006;96:237-44. https://doi.org/10.1016/j.prosdent.2006.08.010
- Rosentritt M, Steiger D, Behr M, Handel G, Kolbeck C. Influence of substructure design and spacer settings on the in vitro performance of molar zirconia crowns. J Dent 2009;37:978-83. https://doi.org/10.1016/j.jdent.2009.08.003
- Coelho PG, Silva NR, Bonfante EA, Guess PC, Rekow ED, Thompson VP. Fatigue testing of two porcelain-zirconia allceramic crown systems. Dent Mater 2009;25:1122-7. https://doi.org/10.1016/j.dental.2009.03.009
- Marchack BW, Futatsuki Y, Marchack CB, White SN. Customization of milled zirconia copings for all-ceramic crowns: a clinical report. J Prosthet Dent 2008;99:169-73. https://doi.org/10.1016/S0022-3913(08)00028-0
- Shoher I, Whiteman AE. Reinforced porcelain system: a new concept in ceramometal restorations. J Prosthet Dent 1983;50:489-96. https://doi.org/10.1016/0022-3913(83)90567-X
- Marker JC, Goodkind RJ, Gerberich WW. The compressive strength of nonprecious versus precious ceramometal restorations with various frame designs. J Prosthet Dent 1986;55:560-7. https://doi.org/10.1016/0022-3913(86)90031-4
- Sailer I, Fehér A, Filser F, Lüthy H, Gauckler LJ, Schärer P, Franz Hämmerle CH. Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow-up. Quintessence Int 2006;37:685-93.
- Al-Amleh B1, Lyons K, Swain M. Clinical trials in zirconia: a systematic review. J Oral Rehabil 2010;37:641-52.
- Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Spiekermann H. Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results. Int J Prosthodont 2008;21:217-22.
- Larsson C1, El Madhoun S, Wennerberg A, Vult von Steyern P. Fracture strength of yttria-stabilized tetragonal zirconia polycrystals crowns with different design: an in vitro study. Clin Oral Implants Res 2012;23:820-6. https://doi.org/10.1111/j.1600-0501.2011.02224.x
- Swain MV. Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures. Acta Biomater 2009;5:1668-77. https://doi.org/10.1016/j.actbio.2008.12.016
- Richerson D, Richerson DW, Lee WE. Modern ceramic engineering: properties, processing and use in design. 3rd ed. Boca Raton: Taylor and Francis Group; 2006.
- Bonfante EA, da Silva NR, Coelho PG, Bayardo-González DE, Thompson VP, Bonfante G. Effect of framework design on crown failure. Eur J Oral Sci 2009;117:194-9. https://doi.org/10.1111/j.1600-0722.2008.00608.x
- Khers SC, Carpenter CW, Vetter JD, Staley RN. Anatomy of cusps of posterior teeth and their fracture potential. J Prosthet Dent 1990;64:139-47. https://doi.org/10.1016/0022-3913(90)90168-C
- Pinho ST, D'avila CG, Camanho PP, Iannucci L, Robinson P. Failure models and criteria for FRP under in-plane or threedimensional stress states including shear non-linearity. NASA/TM-2005-213530, L-19089.
- Cavel WT, Kelsey WP, Blankenau RJ. An in vivo study of cuspal fracture. J Prosthet Dent 1985;53:38-42. https://doi.org/10.1016/0022-3913(85)90061-7
- Farah JW, Craig RG. Distribution of stresses in porcelainfused-to-metal and porcelain jacket crowns. J Dent Res 1975;54:255-61.
- Craig RG, el-Ebrashi MK, Peyton FA. Stress distribution in porcelain-fused-to-gold crowns and preparations constructed with photoelastic plastics. J Dent Res 1971;50:1278-83. https://doi.org/10.1177/00220345710500053101
- Nally JN, Farah JW, Craig RG. Experimental stress analysis of dental restorations. IX. Two-dimensional photoelastic stress analysis of porcelain bonded to gold crowns. J Prosthet Dent 1971;25:307-16. https://doi.org/10.1016/0022-3913(71)90192-2
- Lawn BR, Pajares A, Zhang Y, Deng Y, Polack MA, Lloyd IK, Rekow ED, Thompson VP. Materials design in the performance of all-ceramic crowns. Biomaterials 2004;25:2885-92. https://doi.org/10.1016/j.biomaterials.2003.09.050
- Kleinfelder JW, Ludwigt K. Maximal bite force in patients with reduced periodontal tissue support with and without splinting. J Periodontol 2002;73:1184-7. https://doi.org/10.1902/jop.2002.73.10.1184
Cited by
- Veneered Zirconia-Based Restorations Fracture Resistance Analysis pp.1059941X, 2016, https://doi.org/10.1111/jopr.12490
- Effect of Two Polishing Systems on Surface Roughness, Topography, and Flexural Strength of a Monolithic Lithium Disilicate Ceramic pp.1059941X, 2017, https://doi.org/10.1111/jopr.12586
- Effect of screw access hole design on the fracture resistance of implant-supported zirconia-based restorations pp.14964155, 2018, https://doi.org/10.1111/jerd.12422
- Mechanical and Surface Properties of Monolithic Zirconia vol.43, pp.3, 2018, https://doi.org/10.2341/17-019-L
- Numerical Analysis of a Dental Zirconium Restoration and the Stresses That Occur in Dental Tissues vol.2019, pp.None, 2015, https://doi.org/10.1155/2019/1049306
- Effect of artificial aging on high translucent dental zirconia: simulation of early failure vol.128, pp.6, 2015, https://doi.org/10.1111/eos.12739
- Shear Bond Strength of Veneered Zirconia Repaired Using Various Methods and Adhesive Systems: A Comparative Study vol.13, pp.6, 2015, https://doi.org/10.3390/polym13060910
- A REVIEW OF MECHANICAL BEHAVIOR OF DENTAL CERAMIC RESTORATIONS vol.21, pp.8, 2015, https://doi.org/10.1142/s0219519421500639