An Analysis on a Torque Error of a 3-Phase Induction Motor due to Simplified Equivalent Circuit

3상 유도전동기의 간이등가회로에 의한 토크 오차 분석

  • Shin, Myoung-Ho (Dept. of Electrical and Information Engineering, Seoul Nat'l Univ. of Science and Technology)
  • 신명호 (서울과학기술대학교 전기정보공학과)
  • Received : 2013.10.02
  • Accepted : 2013.10.28
  • Published : 2014.01.31

Abstract

Torque of an induction motor is generally calculated by simplified equivalent circuit. However, the torque has an error since it is calculated by simplified equivalent circuit. In this paper, stator and rotor currents, torque, efficiency, and power factor are derived from the equivalent circuit of an induction motor using mesh analysis method. Then, they are compared with those calculated from simplified equivalent circuit.

Keywords

Acknowledgement

Supported by : 서울과학기술대학교

References

  1. M.-H. Shin, D.-S. Hyun, and S.-B. Cho "Maximum torque control of stator-flux-oriented induction machine drive in the field-weakening region" IEEE Trans. on IA, vol. 38, no. 1, pp. 117-122, 2002.
  2. Myoung-Ho Shin, "Analysis on Parameter Detuning of Induction Motor Drives in Constant Torque Region", Journal of KIIEE, vol. 26, no. 11, pp. 81-86, 2012. https://doi.org/10.5207/JIEIE.2012.26.11.081
  3. Yoon-Jong Lee, "Electric Machinery" Dongmyoung Press, Korea, pp. 285-286, 2001.
  4. Stephen J. Champan, "Electric Machinery Fundamentals", 5th Edition, McGraw-Hill Korea, 2012.
  5. Energy Conversion Lab. of Hanyang Univ., "Electric Machinery", 2nd Edition, Hongneung Science Press, Korea,pp.373, 2011.
  6. Myoung-Ho Shin, "Errors of Proportional Shifting due to Simplified Equivalent Circuit of a 3-Phase Induction Motor", Journal of KIIEE, vol. 27, no. 1, pp. 109-112, 2013. https://doi.org/10.5207/JIEIE.2013.27.1.109