References
- ACI Committee 349. (1990). "Code requirements for nuclear safety related concrete structures (ACI 349-01): Appendix B Anchoring to Concrete." pp. 80-86.
- Hwang, Y. S. (2010). A study on the fracture resistance characteristics of post-installed anchor, M.S. Dissertation, Seoul National University of Science and Technology.
- Jin, S. H. (2011). Tension and shear strenth valuation of large size concrete anchor bolt, M.S. Dissertation, Pusan National University.
- Kim, J. S., Kwon, M. H., Seo, H. S. and Park, J. H. (2013). "Performance evaluation and analysis model for the post-installed anchor." Journal of Korean Society of Hazard Mitigation, Korean Society of Hazard Mitigation, Vol. 13, No. 2, pp. 89-95 (in Korean).
- Kim, S. Y., Han, D. J. and Shin, C. H. (2005). "Strength of anchors under load applied angles." Journal of Korean Society of Hazard Mitigation, Korean Society of Hazard Mitigation, Vol. 5, No. 1, pp. 69-76 (in Korean).
- Kim, S. Y. and Kim, K. S. (2003). "Shear strength of anchors installed in uncracked and unreinforced concrete." Journal of the Architectural Institute of Korea, Architectural Institute of Korea, Vol. 19, No. 9, pp. 69-78 (in Korean).
- Ko, J. Y., Kim, S. Y., Kim, Y. H., Seo, S. Y. and Kim, K. S. (2002). "Shear strength of single anchors in uncracked and unreinforced concrete." Proceedings of Annual Conference of the Architectural Institute of Korea, Architectural Institute of Korea, Vol. 22, No. 2, pp. 197-200 (in Korean).
- Lee, K. M., Lee, C. Y., Jung, S. H. and Choi, S. W. (2009). "Tensile and shear test method for post-installed mechanical anchors embedded in concrete." Proceedings of Magazine of the Korea Concrete Institute, KCI, Vol. 2009, No. 5, pp. 97-98 (in Korean).
- Moon, I. H. and Lee, N. H. (2000). "Break-out strength of anchor bolt based on concrete fracture model." Proceedings of Conference on Korean Society of Civil Engineers, KSCE, pp. 801-804 (in Korean).
- Nam, Y. H. (2006). Development of automated design system for concrete anchor systems, M.S. Dissertation, Hanyang National University.
- Son, J. W. (2002). Fracture analysis of concrete anchor systems subjected to shear loads, M.S. Dissertation, Yonsei University.
- Werner, F. and Rolf, E. (1989). Tragverhalten con befestin-gungsmittein im gerissenen beton bei querzugbeanspruchung, Report 1/41-89/15 Universtat Stuttgart.
- Werner, F., Rolf, E. and John E. B. (1995). "Concrete capacity design(CCD) approach for fastening to concrete." ACI Structural Journal, Vol. 92, No. 1, pp. 73-94.
- Wiewel, H. (1991). Design guidelines for anchorage to concrete, ACI SP-130, pp. 1-18.
- Yoo, S. W., Jung, S. H., Kwak, K. S. and Lee, J. H. (2006). "Experimental study on pull out characteristics of adhesive anchor." Journal of the Korean Society of Civil Engineers, KSCE, Vol. 26, No. 3, pp. 555-563 (in Korean).
Cited by
- A Parameter Study on the Shear Failure Behavior of Post-installed Set Anchor for Light Load vol.19, pp.3, 2015, https://doi.org/10.11112/jksmi.2015.19.3.055
- An Experimental Study on the Shear Behaviour of Post-Installed Anchors for Seismic Retrofit vol.30, pp.9, 2014, https://doi.org/10.5659/JAIK_SC.2014.30.9.41
- Structural Performance Evaluation of Bolt Connection for Half-sphere Joint between PHC Pile and Steel Column vol.15, pp.4, 2015, https://doi.org/10.9712/KASS.2015.15.4.065