References
- Duret F, Blouin JL, Duret B. CAD-CAM in dentistry. J Am Dent Assoc 1988;117:715-20. https://doi.org/10.14219/jada.archive.1988.0096
- Priest G. Virtual-designed and computer-milled implant abutments. J Oral Maxillofac Surg 2005;63:22-32.
- Calamia JR. Advances in computer-aided design and computer- aided manufacture technology. J Philipp Dent Assoc 1996; 48:31-40.
- Duke ES. The status of CAD/CAM in restorative dentistry. Compend Contin Educ Dent 2001;22:968-72.
- Grossmann Y, Pasciuta M, Finger IM. A novel technique using a coded healing abutment for the fabrication of a CAD/ CAM titanium abutment for an implant-supported restoration. J Prosthet Dent 2006;95:258-61. https://doi.org/10.1016/j.prosdent.2005.12.013
- Wiskott HW, Belser UC, Scherrer SS. The effect of film thickness and surface texture on the resistance of cemented extracoronal restorations to lateral fatigue loading. Int J Prosthodont 1999;12:255-62.
- Binon PP. Evaluation of machining accuracy and consistency of selected implants, standard abutments, and laboratory analogs. Int J Prosthodont 1995;8:162-78.
- Binon PP, McHugh MJ. The effect of eliminating implant/ abutment rotational misfit on screw joint stability. Int J Prosthodont 1996;9:511-9.
- Cibirka RM, Nelson SK, Lang BR, Rueggeberg FA. Examination of the implant-abutment interface after fatigue testing. J Prosthet Dent 2001;85:268-75. https://doi.org/10.1067/mpr.2001.114266
- Jörnéus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992;7:353-9.
- McGlumphy EA, Mendel DA, Holloway JA. Implant screw mechanics. Dent Clin North Am 1998;42:71-89.
- Haack JE, Sakaguchi RL, Sun T, Coffey JP. Elongation and preload stress in dental implant abutment screws. Int J Oral Maxillofac Implants 1995;10:529-36.
- Martin WC, Woody RD, Miller BH, Miller AW. Implant abutment screw rotations and preloads for four different screw materials and surfaces. J Prosthet Dent 2001;86:24-32. https://doi.org/10.1067/mpr.2001.116230
- Byrne D, Houston F, Cleary R, Claffey N. The fit of cast and premachined implant abutments. J Prosthet Dent 1998;80: 184-92. https://doi.org/10.1016/S0022-3913(98)70108-8
- Coelho AL, Suzuki M, Dibart S, DA Silva N, Coelho PG. Cross-sectional analysis of the implant-abutment interface. J Oral Rehabil 2007;34:508-16. https://doi.org/10.1111/j.1365-2842.2007.01714.x
- Groten M, Girthofer S, Pröbster L. Marginal fit consistency of copy-milled all-ceramic crowns during fabrication by light and scanning electron microscopic analysis in vitro. J Oral Rehabil 1997;24:871-81. https://doi.org/10.1046/j.1365-2842.1997.00592.x
- Groten M, Axmann D, Pröbster L, Weber H. Determination of the minimum number of marginal gap measurements required for practical in-vitro testing. J Prosthet Dent 2000;83: 40-9. https://doi.org/10.1016/S0022-3913(00)70087-4
- Sorensen JA. A standardized method for determination of crown margin fidelity. J Prosthet Dent 1990;64:18-24. https://doi.org/10.1016/0022-3913(90)90147-5
- Anusavice KJ, Carroll JE. Effect of incompatibility stress on the fit of metal-ceramic crowns. J Dent Res 1987;66:1341-5. https://doi.org/10.1177/00220345870660081101
- Rinke S, Hüls A, Jahn L. Marginal accuracy and fracture strength of conventional and copy-milled all-ceramic crowns. Int J Prosthodont 1995;8:303-10.
- Yeo IS, Yang JH, Lee JB. In vitro marginal fit of three all-ceramic crown systems. J Prosthet Dent 2003;90:459-64. https://doi.org/10.1016/j.prosdent.2003.08.005
- Richter EJ. In vivo vertical forces on implants. Int J Oral Maxillofac Implants 1995;10:99-108.
- Sakaguchi RL, Douglas WH, DeLong R, Pintado MR. The wear of a posterior composite in an artificial mouth: a clinical correlation. Dent Mater 1986;2:235-40. https://doi.org/10.1016/S0109-5641(86)80034-3
- Hakimeh S, Vaidyanathan J, Houpt ML, Vaidyanathan TK, Von Hagen S. Microleakage of compomer class V restorations: effect of load cycling, thermal cycling, and cavity shape differences. J Prosthet Dent 2000;83:194-203. https://doi.org/10.1016/S0022-3913(00)80012-8
- Lewis S, Beumer J 3rd, Hornburg W, Moy P. The "UCLA" abutment. Int J Oral Maxillofac Implants 1988;3:183-9.
- Quek HC, Tan KB, Nicholls JI. Load fatigue performance of four implant-abutment interface designs: effect of torque level and implant system. Int J Oral Maxillofac Implants 2008;23:253-62.
- Steinebrunner L, Wolfart S, Ludwig K, Kern M. Implantabutment interface design affects fatigue and fracture strength of implants. Clin Oral Implants Res 2008;19:1276-84. https://doi.org/10.1111/j.1600-0501.2008.01581.x
- Pyzdek T. Quality engineering handbook. In: Keller PA (ed). Planning, controlling, and assuring product and process quality. 2nd ed., New York: Marcel Dekker, 2003, p. 226-30.
- Kalpakjian S. Manufacturing engineering and technology. In: Schmid S (ed). Cold welding and roll bonding. 5th ed., Upper Saddle River, NJ: Pearson/Prentice Hall, 2006, p. 981.
- Sutter F, Weber HP, Sorensen J, Belser U. The new restorative concept of the ITI dental implant system: design and engineering. Int J Periodont Res Dent 1993;13:409-431.
- Norton MR. An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design. Clin Oral Implants Res 1997;8:290-8. https://doi.org/10.1034/j.1600-0501.1997.080407.x
Cited by
- Peri-implantitis and the prosthodontist vol.223, pp.5, 2017, https://doi.org/10.1038/sj.bdj.2017.755
- Effects of cleaning methods for custom abutment surfaces on gene expression of human gingival fibroblasts vol.59, pp.4, 2014, https://doi.org/10.2334/josnusd.16-0681