Abstract

Evacuation fire doors were manufactured by applying phosphorescent paint to the whole fire door whose performance was already recognized, and applying heat sensitive paint around the grip. The facility was improved by the evacuation and safety functions on the fire door, which has been used as only a fire facility, and the fire door is also used as an evacuation facility. The brilliance of the evacuation safety fire door manufactured in this study passed the brilliance test of Korea Fire Institute with a performance more than the brilliance (7mcd after 60 minutes) of the existing inducement sign. During a fire, the visible area is larger than the evacuation door inducement, etc. and light preventive status in the lower part of the fire door was observed during the descent of smoke. Therefore, it is considered to extend the evacuation effective time of evacuators. In heat sensitive paint applied around the grip, a color change is observed on the fire door when approaching a certain temperature ($70^{\circ}C$). Therefore, the first disaster that evacuators can encounter on the grip of a fire door during a fire can be prevented and should be helpful in recognizing the backfiring possibility and preventing safety accidents for firefighters who must enter a fire space.

피난방화문이란 기존에 성능을 인정받은 방화문의 전면에 축광도료를 바르고 손잡이 부근에는 시온도료를 발라 제작한 방화문으로 기존에 방화설비로만 사용되었던 방화문에 피난 및 안전 기능을 추가, 방화문 자체가 피난설비로서의 기능을 겸용하는 설비이다. 피난안전방화문의 휘도는 기존의 유도표지 휘도(60분후 7mcd)이상의 성능으로 한국소방산업기술원의 휘도시험을 통과한 설비로, 화재 시 가시성의 면적이 피난구유도등에 비해 크며 연기의 하강에도 방화문 아랫부분의 방광상태가 관찰되어 피난자들의 피난유효 시간을 연장시켜 줄 것으로 사료된다. 손잡이 부근에 발라져 있는 시온도료는 일정온도에 도달하면($70^{\circ}C$) 색상이 변화 위험경고가 방화문 바탕에 나타나게 되어 화재 시 피난자들이 방화문 손잡이에 입을 수 있는 1차 재해를 예방할 수 있으며, 화재공간에 진입을 하여야 하는 소방관들에게는 역화 가능성을 사전에 인지 안전 사고를 예방하는데 도움을 줄 것으로 판단된다.

Keywords

References

  1. Eun-Sun Baek, Geon-Jong Baek, Hoon Shin, Min-Jeong Song, Chan Kook, Sun-Woo Kim, "A study on the awareness of fire safety and evacuation guide system" Journal of korean institute of fir science & engineering., Vol. 24, No. 6, pp45-53, 2010.
  2. Myoung-Sin Ahn, "A study of the improvement methodology of the performance and the maintenance efficiency of the management of exit light" P.87, University of Seoul, 2008.
  3. Jae-Cheol Lee, "Analysis of the cause of fire and fire safety service for Multiple complex", P.75, Kyungli University, 2010.
  4. Man-Sung Hur, Akihiro Fujita, Bitosho, "A Study about the Evacuation Guidance that Used Phosphorescent Material for Stairs" Journal of korean institute of fir science & engineering., Vol. 22, No. 1, pp29-36, 2008.
  5. Wook-Jung Na, Gyu-Yeob Jeon, Won-Hwa Hong, "A study on Comparison with Evacuation Performance according to the type of Egress Induction Equipment" Fall Conference of the KIAEBS., P.249-252, 2007.
  6. Jeong-Soo Lee, Heung-Soon Kwon, "Evacuation Behaviors under the Corridor and Stair Width Variations in Evacuation Experiments" Journal of the Korea Academia-Industrial cooperation Society Vol. 13, No. 5 pp. 2374-2381, 2012. DOI: http://dx.doi.org/10.5762/KAIS.2012.13.5.2374
  7. National Emergency Management Agency, "Status of fire statistics" 2012.