참고문헌
- J. Lee and J. Lin, "A microprocessor-based noninvasive arterial pulse wave analyzer", IEEE Trans. Biomed. Eng., Vol. 32, No. 6, pp.451-455, 1985.
- M. Sherebrin and R. Sherebrin, "Frequency analysis of the peripheral pulse wave detected in the finger with a photoplethysmograph", IEEE Trans. Biomed. Eng., Vol. 37, No. 3, pp.313-317, 1990. https://doi.org/10.1109/10.52332
- G. Pressman and P. Newgard, "A transducer for the continuous external measurement of arterial blood pressure", IEEE Trans. Biomed. Eng., Vol. 10, No. 2, pp.73-81, 1963.
- D. Hkanson, D. Strandness, and C. Miller, "An echo tracking system for recording arterial-wall motion", IEEE Trnas. Sonics Ultrson., Vol. 17, No. 3, pp.130-132, 1970. https://doi.org/10.1109/T-SU.1970.29551
- B. Lee, J. Jung, and K. Chun, "A cantilever type contact force sensor array for blood pressure measurement", J. Sensor Sci. & Tech., Vol. 21, No. 2, pp. 121-126, 2012. https://doi.org/10.5369/JSST.2012.21.2.121
- J. Kim, S. Jee, and S. Yoo, "Fabrication and evaluation of sensor for measuring pulse wave velocity using piezo film and conductive textile", J. Sensor Sci. & Tech., Vol. 21, No. 2, pp. 135-143, 2012. https://doi.org/10.5369/JSST.2012.21.2.135
- Y. Noh and D. Jeong, "Basic study for stress analysis using an unconstrained BCG monitoring system", J. Sensor Sci. & Tech., Vol. 20, No. 2, pp. 118-123, 2011. https://doi.org/10.5369/JSST.2011.20.2.118
- J. Park, "Fiber Fabry-Perot interferometrric sensor for the measurment of electric current flowing through a fuse", Jpn. J. Appl. Phys., Vol. 46, No. 6A , pp. 3665-3666, 2007. https://doi.org/10.1143/JJAP.46.3665
- S. Eom, J. Park, and J. Lee, "Optical fiber arterial pulsewave sensor", Microwave and Optical Tech. Lett., Vol. 52, No. 6, pp. 1318-1321, 2010. https://doi.org/10.1002/mop.25200
- E. Stenow and P. Oberg, "Venous occlusion plethysmography using a fiber-optic sensor", IEEE Trans. Biomed. Eng., Vol. 40, No. 3, pp. 284-288, 1993. https://doi.org/10.1109/10.216412
- O. Tohyama, M. Kohashi, M. Sugihara, and H. Itoh, "A fiber-optic pressure microsensor for biomedical applications", Sens. Actuator A-Phys., Vol. 66, No. 1, pp. 150-154, 1998. https://doi.org/10.1016/S0924-4247(97)01764-0
- A. Grillet, D. Kinet, J. Witt, M. Schukar, K. Krebber, F. Pirotte, and A. Depre, "Optical fiber sensors embedded into medical textiles for healthcare monitoring", IEEE Sensors J., Vol. 8, No. 7, pp. 1215-1222, 2008. https://doi.org/10.1109/JSEN.2008.926518
- K. Oh, S. Choi, Y. Jung, and J. Lee, "Novel hollow optical fibers and their applications in photonic devices for optical communications", J. Lightwave Technol., Vol. 23, pp. 524-532, 2005. https://doi.org/10.1109/JLT.2004.842307
- S. Kim, J. Park, and W. Han, "Optical fiber AC voltage sensor", Microwave and Optical Tech.. Lett., Vol. 51, No. 7, pp. 1689-1691, 2009. https://doi.org/10.1002/mop.24434
- Y. Yeh, C. Lee, R. Atkins, W. Gibler, and H. Taylor, "Fiber optic sensor for substrate temperature monitoring", J. Vac. Sci. Technol. A, Vol. 8, No. 4, pp. 3247-3250, 1990. https://doi.org/10.1116/1.576572
- H. Seo, A study on the implementation of USN module for an environment purifying using zigbee, Master Thesis, Hanbat National University, 2006.
- J. Park, K. Lee, and Y. Shin, "An energy efficient clustering scheme by adjusting group size in zigbee environment", J. Sensor Sci. & Tech., Vol. 19, No. 5, pp. 342-348, 2010. https://doi.org/10.5369/JSST.2010.19.5.342
피인용 문헌
- Real Time Driver's Respiration Monitoring vol.23, pp.2, 2014, https://doi.org/10.5369/JSST.2014.23.2.142