DOI QR코드

DOI QR Code

A Study on Performance Characteristics of Wetted-type Multi Path Ultrasonic Flowmeter

습식 다회선 초음파유량계의 특성평가 연구

  • Lee, Dong-Keun (K-water Institute, Korea Water Resources Corporation) ;
  • Cho, Yong (K-water Institute, Korea Water Resources Corporation) ;
  • Ko, Jae-Myoung (K-water Institute, Korea Water Resources Corporation) ;
  • Park, Tae-Jin (K-water Institute, Korea Water Resources Corporation) ;
  • Park, Jong-Ho (Dept. of Mechanical Eng., Chungnam National University)
  • Received : 2011.06.08
  • Accepted : 2013.07.23
  • Published : 2013.08.01

Abstract

An experimental investigation has been carried out in order to evaluate characteristics of wetted-type multi-path ultrasonic flowmeters. The multi-path ultrasonic flowmeters were installed at various entrance and exit locations for several cases of pipe fitting(straight, $90^{\circ}$ double elbow) and valve(gate valve, butterfly valve). We measured the flow-rate at each location. The measurement data of test flowmeter were compared with the measured data of reference flowmeter. The uncertainties of reference flowmeter and test flowmeter are 0.3 %, 0.4 %, respectively. The results demonstrate the effects of flowmeter location as well as the measurement errors in flow rate. The distance between the flow disturbance factor and a flowmeter was an important element of the test.

Keywords

References

  1. Drenthen, J. G. and de Boer, G., 2001, "The Manufacturing of Ultrasonic Gas Flow Meters," Flow Measurement and Instrumentation, Vol. 12, pp. 89-99. https://doi.org/10.1016/S0955-5986(01)00003-6
  2. Park, K. A., Choi, Y. M., Choi, H. M., Yoon, B. R., and Hwang, K. B., 1999, "Installation Effects on the Characteristics of Multi-path Ultrasonic Flowmeter," Proceedings of the KFMA Annual Meeting, pp. 114-117.
  3. Hwang, S. Y., Seo, K. H., Kim, B. C., Kim, K. S., and Tyan, H. S, 2000, "Installation Effects on the Characteristics of Multi-path Ultrasonic Flowmeter with Valve," Proceedings of the KFMA Annual Meeting, pp. 65-74.
  4. Carlander, C. and Delsing, J. 2000, "Installation Effects on an Ultrasonic Flow Meter with Implications for Self Diagnostics," Flow Measurement and Instrumentation, Vol. 11. pp. 109-122. https://doi.org/10.1016/S0955-5986(00)00005-4
  5. Yeh, T. T. and Mattingly, G. E., 1997, "Computer Simulations of Ultrasonic Flow Meter Performance in Ideal and Non-ideal Pipeflows," ASME Fluids Engineering Division Summer Meeting, pp. 1-6.
  6. Ruppel. C. and Peter. F., 2004, "Effects of Upstream Installation on the Reading of an Ultrasonic Flowmeter," Flow Measurement and Instrumentation, Vol. 15, pp. 166-177.
  7. Berrebi, J., 2004, "Ultrasonic Flow Metering Errors Due to Pulsating Flow," Flow Measurement and Instrumentation, Vol. 15, pp. 179-185. https://doi.org/10.1016/j.flowmeasinst.2003.12.003
  8. Xiong, W., 2003, "Velocity and Turbulence Measurements Downstream of Flow Conditioners," Flow Measurement and Instrumentation, Vol 14, pp. 249-260. https://doi.org/10.1016/S0955-5986(03)00031-1

Cited by

  1. vol.17, pp.2, 2014, https://doi.org/10.5293/kfma.2014.17.2.079