Effectiveness of a fast spin echo technique using the signal void in acquisition of black blood images

흑혈류영상 획득 시 신호소실을 활용한 고속스핀에코기법의 유용성

  • Choi, Kwan-Woo (Department of Health Science, Graduate School Hanyang University) ;
  • Kim, Yoon-Shin (Department of Health Science, Graduate School Hanyang University) ;
  • Son, Soon-Yong (Department of Radiology, Asan Medical Center) ;
  • Lee, Hee-Ju (Department of Radiology, Asan Medical Center) ;
  • Min, Jung-Whan (Department of Radiology, Shin-Gu University) ;
  • Lee, Jong-Seok (Department of Radiotechnology, Wonkwang Health Science University) ;
  • Yoo, Beong-Gyu (Department of Radiotechnology, Wonkwang Health Science University)
  • 최관우 (한양대학교 대학원 보건학과) ;
  • 김윤신 (한양대학교 대학원 보건학과) ;
  • 손순룡 (서울아산병원 영상의학과) ;
  • 이희주 (서울아산병원 영상의학과) ;
  • 민정환 (신구대학교 방사선과) ;
  • 이종석 (원광보건대학교 방사선과) ;
  • 유병규 (원광보건대학교 방사선과)
  • Received : 2013.06.24
  • Accepted : 2013.09.06
  • Published : 2013.09.30

Abstract

The purpose of our study is to shorten the scanning time and minimize the inconveniences of the patients in acquisition of the black blood images using the signal void effect in the fast spin echo technique while keeping the diagnostic value of the test. Thirty-two consecutive patients who underwent black blood MR imaging were examed with additional double inversion recovery (DIR) sequence and the conventional fast spin echo (FSE) sequence. Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of the internal carotid arteries' lumen were compared in T1 and T2 weighted images to determine whether there are differences between the two techniques for depiction of the signal void effect inside the vessel wall. The FSE images showed lower SNR values than the DIR images in both of the T1 and T2 weighted images (11.49% and 13.66% respectively). While the CNR values were higher in the FSE images than in the DIR images in both of the T1 and T2 weighted images (8.69% and 7.55% respectively).There was no significant difference between the two techniques for either of the SNR or CNR (p>0.05, p>0.05 respectively). The DIR and the FSE images demonstrated almost identical imaging patterns. Therefore, it is anticipated that the use of FSE technique in acquisition of the black blood imaging could reduce the inconveniences of the patients during the scanning and minimize exam time while keeping the diagnostic value of the test.

본 연구는 흑혈류영상 획득에서 고속스핀에코기법의 신호소실 현상을 이용하여 검사시간을 최소화시켜 환자의 불편을 줄이고 진단적 가치를 유지하고자 하였다. 연구방법은 흑혈류영상을 획득한 환자 32명을 대상으로, 기존의 이중역전회복기법과 새로운 기법인 고속스핀에코기법을 각각 적용한 후, 기법에 따른 혈류의 신호소거 차이를 알아보기 위해 T1, T2 강조영상에서 내경동맥 내강의 SNR과 CNR을 비교 평가하였다. 연구결과, SNR은 고속스핀에코기법이 이중역전회복기법 보다 T1, T2 강조영상에서 11.49%(4.73), 13.66%(6.03) 낮았으며, CNR은 고속스핀에코기법이 T1 강조영상에서 8.69%(15.04) 높았고, T2 강조영상에서 7.55% (13.17) 낮았으나, 통계적 수준에서 두 기법간의 SNR과 CNR의 차이는 유의하지 않았다. 그러므로 흑혈류영상 획득 시 고속스핀에코기법을 이용한다면 진단적 가치는 유지하면서 검사시간을 최소화하여 환자의 불편을 줄일 수 있다고 판단된다.

Keywords

References

  1. H. S. Seo, "Pathophysiology of Atherosclerosis", Clinical Vascular Medicine, pp. 14-25, 2009.
  2. Seoul National University Hospital. Knowledge encyclopedia. NHN Corp., Available From: http://terms.naver.com/entry.nhn?cid=865&docId=92733 8&mobile&categoryId=1747, (accessed Jan., 23, 2013)
  3. D. K. Lee, Y. J. Kwon, S. M. Lee, J. Y. Yang, C. S. Choi, M. B. Ju, "MR Angiographic Findings in Ischemic Stroke patients with Extracranial Caretid Artery Stenosis", J Korean Neurosurg Soc., Vol. 33, pp. 353-357, 2003.
  4. Jean M, Rikin A, Evis Sala, Martin J, Mathew G, Nicholas J, Justin C, William H, Richard A, Peter J, Nagui M, Jonathan H, "Evaluation of carotid stenosis with acial high resolution black-blood MR imaging", Eur Radiol., Vol. 14, pp. 1154-1161, 2004.
  5. Tobias S, Jose G, Clemens C, Katja B, Georgios M, Olaf D, Dirk A, Ute F, Chun Y, Thomas S, Abd W, Maximilian F, Konstantin N, "High resolution carotid black-blood 3T MR with parallel imaging and dedicated 4-channel surface coils", J Cardiovasc Magn Reson., pp. 1-12, 2009. DOI: http://dx.doi.org/10.1186/1532-429X-11-41
  6. H. K. Song, Alexander C, Ronald L, Felix W, "Multislice Double Inversion Pulse Sequence for Efficient Black-Blood MRI", Magn Reson Med., Vol. 47, pp. 616-620, 2002. DOI: http://dx.doi.org/10.1002/mrm.10094
  7. Stavros M, Jonathan N, William A, Alan J, "Does black blood MRA have an rele in th assessment of intracerebral aneurysms?", Eur Radiol, Vol. 19, pp. 184-192, 2009. DOI: http://dx.doi.org/10.1007/s00330-008-1127-2
  8. Mathias Goyen, Tomas C. Lauenstein, Christoph U. Herborn, Jorg F, Debatin, MBA, Silke Bosk, Stefan G, Ruehm, "0.5M Gd chelate(Magnevist) Versus 1.0M Gd Chelate(Gadovist): Dose-Independent Effect on Image Quality of Pelvic Three-Dimensional MR-Angiography", J Magn Reson Imaging., Vol 14, pp. 602-607, 2001. DOI: http://dx.doi.org/10.1002/jmri.1225
  9. S. Haneder, U. Attenberger1, S. O. Schonberg, C. Loewe, J. Arnaiz Garcia, H. J. Michaely, Mannheim/DE, Vienna/AT, Santander/ES, "Intra-individual efficacy evaluation of Dotarem(R)-enhanced MRA compared to Gadovist(R)-enhanced MRA in the diagnosis of clinically significant abdominal or lower limb arterial diseases", Eur Radiol., pp. C-1016, 2010.
  10. Tobias S, Jose G, Clemens C, Katja B, Georgios M, Olaf D, Dirk A, Ute F, Chun Y, Thomas S, Abe W, Maximilian F, Konstantin N, "High resolution carotid black-blood 3T MR with parallel imaging and dedicated 4-channel surface coils", J Cardiovasc Magn Reson., Vol. 11, pp. 1-12, 2009. https://doi.org/10.1186/1532-429X-11-1
  11. Sarah C, Khaled A, Daniel R, Messroghli, Timothy J, John P, Ridgway Mohan U, "The reproducibility of left ventricular volume and mass measurements: a comparison between dual-inversion-recovery black-blood sequence and SSFP", Eur Radiol, Vol. 16, pp. 32-37, 2006. DOI: http://dx.doi.org/10.1007/s00330-005-2853-3
  12. SeshaSailaja A, H. K. Song, Alexander C, Felix W, "High-resolution black-blood MRI of the carotid vessel wall using phased-array coils at 1.5 and 3 Tesla", Acad Radiol., Vol. 12, pp. 1521-1526, 2005. DOI: http://dx.doi.org/10.1016/j.acra.2005.08.009
  13. Indesey C, Peter G, Clare C, David N, FIRMIN, "A Volume Selective 3D Turbo Spin Echo Sequence for Vessel Wall and Ompliance Measurement", J Magn Reson Imaging., Vol. 10, pp. 1, 2002.
  14. Benjamin W, Lowie M, Han W. K, Lubna B, Christoph J, Elizabeth J, Wolfgang G, Deneen Spatz1, Y. Y. Kim, Michele P, Raymond J, "Assessment and improvement of image homogeneity in black-blood T2-weighted turbo spin-echo CMR", J Cardiovasc Magn Reson., pp. 1-2, 2012. DOI: http://dx.doi.org/10.1186%2F1532-429X-14-S1-O113 https://doi.org/10.1186%2F1532-429X-14-S1-O113
  15. Meihan W, Christopher M, Craig H, "DANTE preparation for black-blood coronary wall imaging", J Cardiovasc Magn Reson., pp. 237, 2013. DOI: http://dx.doi.org/10.1186/1532-429x-15-s1-p237