Abstract
One of the most significant requisite that should be considered for effective rapping of the electrostatic precipitator using electromagnetic vibration exciter is vibration acceleration and resonance frequency of collecting plates. This vibration acceleration shows its peak points when natural frequencies of the system are corresponded with excitation frequency from the power source, and effective rapping performance can be expected. In this research, extend view of single electrostatic precipitator using one electromagnetic vibration exciter, the system was remodeled by arrangement of the exciters in view of multiple modules of the electrostatic precipitator in fields. And vibration acceleration measurement experiment is performed and measured values are compared with these remodeled systems. By this experimental comparison in series and parallel arrangement, effectiveness of arrangement methods for the electromagnetic vibration exciter, expected rapping performance, and power consumption are verified.
전자기 진동 가진기를 적용한 전기 집진기의 효과적인 탈진 여부를 판단할 수 있는 기준은 집진기내 집진판들의 진동 가속도이다. 이러한 진동 가속도는 외부로부터의 가진 주파수와 시스템의 고유주파수의 일치로 인하여 공진이 일어날 때 간헐적으로 최대치를 보이며 효율적인 탈진성능을 기대할 수 있다. 본 연구에서는 한대의 전자기 진동 가진기를 이용하는 단일 객체를 대상으로 한 관점에서 더 나아가, 실제 현장에서 복수의 전기집진탈진기가 설치됨을 고려하여 진동 탈진기의 설치방식에 따라 시스템을 모델링 하였다. 이러한 직렬 및 병렬회로로 연결된 가진기를 적용한 시스템을 대상으로 진동 가속도 계측 실험을 수행하여 직렬 및 병렬식 연결에 따른 진동 가속도의 차이를 비교함으로써 가진기의 배열 방식과 그에 따른 기대 탈진 성능 및 소비전력의 유효성을 검증하였다. 최종적으로 직렬 배열형 모듈이 증가할수록 선형적으로 필요전류량이 증가할 것으로 예상하였으나 급격한 감소나 (6.9% ~ 37.6%) 증가를 (5% ~ 45%) 보여주었다. 단독의 가진기가 사용된 병렬 배열보다, 2대의 가진기가 사용되고 그 전기회로의 연결이 병렬일 때 동일한 전류가 인가되었음에도 약 11.64% 의 가속도 감소 현상을 보였다. 2대의 가진기를 사용하고 입력전류의 값을 소비 전력의 관점에서 동일하게 보정하였을 경우 약 16.80 % 의 가속도 증가 현상을 확인하였다.