DOI QR코드

DOI QR Code

Evaluation of Structural Performance of RC Beams Retrofitted Steel Fiber consequential Replacement of Recycled Coarse Aggregate and Ground Granulated Blast Furnace Slag

순환골재와 고로슬래그 미분말을 치환한 강섬유 보강 RC보의 구조성능 평가

  • Ha, Gee-Joo (Dept. of Architecture Engineering, Kyungil University) ;
  • Yi, Dong-Ryul (Construction Technology & Policy Institute) ;
  • Ha, Jae-Hoon (Construction Technology & Policy Institute)
  • Received : 2012.10.22
  • Accepted : 2014.09.04
  • Published : 2013.10.31

Abstract

In this study, eleven reinforced concrete beams, ground granulated blast furnace slag, replacing recycled coarse aggregate (BRS series) and recycled coarse aggregate with steel fiber (BSRS series), and standard specimen (BSS) were constructed and tested under monotonic loading. Experimental programs were carried out to improve and evaluate the shear performance of such test specimens, such as the load-displacement, the failure mode and the maximum load carrying capacity. All the specimens were modeled in 1/2 scale-down size. Test results showed that test specimens (BSRS Series) was increased the compressive strength by 9%, the maximum load carrying capacity by 1~6% and the ductility capacity by 1.02~1.13 times in comparison with the standard specimen (BSS). And the specimens (BSRS Series) showed enough ductile behavior and stable flexural failure.

이 연구에서는 순환골재와 고로슬래그 미분말의 치환율에 따른 강섬유 보강 RC보의 구조성능 향상을 위하여 표준실험체(BSS), 성능개선 실험체로는 순환골재와 고로슬래그 미분말을 치환한 실험체(BRS시리즈), 순환골재와 고로슬래그의 치환율에 강섬유를 보강한 실험체(BSRS시리즈)로 총 11개의 실험체를 1/2축소 제작하여 실험을 수행하였다. 실험을 통하여 얻어진 결과를 비교 분석하여 하중-변위, 파괴형태, 최대내력 등을 규명함으로써 구조성능의 개선정도를 평가하였다. 실험 결과 순환골와 고로슬래그 미분말을 치환한 콘크리트에 강섬유를 보강한 실험체(BSRS시리즈)의 경우 표준실험체(BSS)보다 압축강도는 최대 9%, 최대내력은 1~6%, 연성능력은 각각 1.02~1.13배 증가하는 결과를 나타내었다. 또한, 충분한 연성적인 거동과 안정적인 휨인장 파괴를 나타내었다.

Keywords

References

  1. Korea Concrete Institute, Concrete and Environment, Kimoondang Publishing Company, Seoul, Korea, 2010, 299 pp.
  2. Korea Recycled Construction Resources Association, The Social, Economic and Environmental Values Evaluation and Effectiveness of Recycled Aggregate, 2005, pp. 1-50.
  3. Ministry of Environment, Comprehensive Measures to Promote Recycling of Construction Waste, 2002, pp. 1-16.
  4. Kim, K. W., Park, J. S., Lee, B. H., and Yeon, K. S., "Research and Practical Application of the Reuse of Demolished Concretes," Magazine of the Korea Concrete Institute, Vol. 6, No. 6, 1994, pp. 51-65.
  5. Kim, K. W., Yeon, K. S., and Lee, B. D., "Problems in Strength Characteristics of Recycled Waste Concrete," Proceedings of the Korea Concrete Institute, Vol. 4, No. 2, 1992, pp. 44-49.
  6. Park, J. S., "Engineering Properties of Recycled Aggregate Concrete Using Waste Concretes," Department of Architectural Engineering Graduate School of the Chungbuk National University, 1999, pp. 21-55.
  7. Sim. J. S., Park, C. W., Park, S. J., Kim, Y. J., and Kim, H. J., "Study on the Strength Characteristics of Spun- Concrete Used Recycled Aggregate," Proceedings of the Korea institute for Structural Maintenance Inspection, Vol. 8, No. 2, 2004. pp. 429-434.
  8. Korea Standards Association, KS F 2573, Recycled Aggregate Concrete, 2011, pp. 3-6.
  9. Ministry of Land, Transport and Maritime Affairs, No. 772 of the Act on Palpation of Construction Waste Recycling Regulations Based on Article 35 of the Quality Standards for Recycled Aggregates Announcement, 2009 pp. 1-82.
  10. Ministry of Environment, Promote Recycling of Construction Waste Enforcement Regulations Environmental Enforcement Ordinance of the Act No. 281, 2008.
  11. Korea Institute of Public Administration, To Promote the Recycling of Construction Waste in Accordance with the Act Revised Regulatory Impact Analysis, 2008, pp. 32-35.
  12. Ha, G. J., Shin, J. H., Kwak, Y. K., and Kwon, C. S., "Improvement and Evaluation of Structural Performance of Steel Fiber Reinforced Concrete Beams Using Early Age Concrete," Journal of the Korea institute for Structural Maintenance Inspection, Vol. 3, No. 3, 1999, pp. 129-137.
  13. Ha, G. J., Shin, J. H., and Ju, J. J., "Evaluation on the Flexural Performance of Steel Fiber Reinforced Concrete Beams," Journal of the Korea institute for Structural Maintenance Inspection, Vol. 4, No. 1, 2000. pp. 139-145.
  14. Lee, S. K., "A Study on the Shear Behavior of Recycled Aggregate Concrete Mixing Steel Fiber," Journal of the Korea Testing & Research Institute, Vol. 35, No. 67, 2009, pp. 112-123.
  15. Shin, Y. S., Cho, C. H., Kim, D. S., and Kim J. S., "A Study on the Mechanical Properties of Recycled Aggregate Concrete Mixed Steel Fiber," Journal of the Korea Institute of Building Construction, Vol. 9, No. 4, 2009, pp. 131-137. https://doi.org/10.5345/JKIC.2009.9.4.131
  16. Soroushian, P., Fiber-Type Effects on the Performance of Steel Fiber Reinforced Concrete, American Concrete Institute, 1991, pp. 129-134.
  17. Sharma, A. K., "Shear Strength of Steel Fiber Reinforced Concrete Beams," ACI Structural Journal, Vol. 83, No. 4, 1986, pp. 624-627.