References
- Hebel KS, Gajjar RC. Cement-retained versus screw-retained implant restorations: achieving optimal occlusion and esthetics in implant dentistry. J Prosthet Dent 1997;77:28-35. https://doi.org/10.1016/S0022-3913(97)70203-8
- Chee W, Felton DA, Johnson PF, Sullivan DY. Cemented versus screw-retained implant prostheses: which is better? Int J Oral Maxillofac Implants 1999;14:137-41.
- Taylor TD, Agar JR, Vogiatzi T. Implant prosthodontics: current perspective and future directions. Int J Oral Maxillofac Implants 2000;15:66-75.
- Michalakis KX, Hirayama H, Garefis PD. Cement-retained versus screw-retained implant restorations: a critical review. Int J Oral Maxillofac Implants 2003;18:719-28.
- Vigolo P, Givani A, Majzoub Z, Cordioli G. Cemented versus screw-retained implant-supported single-tooth crowns: a 4-year prospective clinical study. Int J Oral Maxillofac Implants 2004;19:260-5.
- Weber HP, Sukotjo C. Does the type of implant prosthesis affect outcomes in the partially edentulous patient? Int J Oral Maxillofac Implants 2007;22:140-72.
- Michalakis KX, Pissiotis AL, Hirayama H. Cement failure loads of 4 provisional luting agents used for the cementation of implant-supported fixed partial dentures. Int J Oral Maxillofac Implants 2000;15:545-9.
- Breeding LC, Dixon DL, Bogacki MT, Tietge JD. Use of luting agents with an implant system: Part I. J Prosthet Dent 1992;68:737-41. https://doi.org/10.1016/0022-3913(92)90194-F
- Mehl C, Harder S, Wolfar t M, Kern M, Wolfar t S. Retrievability of implant-retained crowns following cementation. Clin Oral Implants Res 2008;19:1304-11. https://doi.org/10.1111/j.1600-0501.2008.01587.x
- Schneider RL. Evaluation of the retention of castings to endosseous dental implants. J Prosthet Dent 1987;58:73-8. https://doi.org/10.1016/S0022-3913(87)80147-6
- Rosenstiel SF, Land MF, Fujimoto J. Contemporary fixed prosthodontics. 4th ed. St. Louis: Mosby; 2006. p. 229.
- Covey DA, Kent DK, St Germain HA Jr, Koka S. Effects of abutment size and luting cement type on the uniaxial retention force of implant-supported crowns. J Prosthet Dent 2000;83:344-8. https://doi.org/10.1016/S0022-3913(00)70138-7
- Akca K, Iplikcioglu H, Cehreli MC. Comparison of uniaxial resistance forces of cements used with implant-supported crowns. Int J Oral Maxillofac Implants 2002;17:536-42.
- Juntavee N, Millstein PL. Effect of surface roughness and cement space on crown retention. J Prosthet Dent 1992;68: 482-6. https://doi.org/10.1016/0022-3913(92)90415-7
- Tuntiprawon M. Effect of tooth surface roughness on marginal seating and retention of complete metal crowns. J Prosthet Dent 1999;81:142-7. https://doi.org/10.1016/S0022-3913(99)70241-6
- Oilo G, Jorgensen KD. The influence of surface roughness on the retentive ability of two dental luting cements. J Oral Rehabil 1978;5:377-89. https://doi.org/10.1111/j.1365-2842.1978.tb01257.x
- Felton DA, Kanoy BE, White JT. The effect of surface roughness of crown preparations on retention of cemented castings. J Prosthet Dent 1987;58:292-6. https://doi.org/10.1016/0022-3913(87)90043-6
- Ayad MF, Rosenstiel SF, Salama M. Influence of tooth surface roughness and type of cement on retention of complete cast crowns. J Prosthet Dent 1997;77:116-21. https://doi.org/10.1016/S0022-3913(97)70223-3
- Ramp MH, Dixon DL, Ramp LC, Breeding LC, Barber LL. Tensile bond strengths of provisional luting agents used with an implant system. J Prosthet Dent 1999;81:510-4. https://doi.org/10.1016/S0022-3913(99)70203-9
- Grasso CA, Caluori DM, Goldstein GR, Hittelman E. In vivo evaluation of three cleansing techniques for prepared abutment teeth. J Prosthet Dent 2002;88:437-41. https://doi.org/10.1067/mpr.2002.128123
- Erkut S, Kucukesmen HC, Eminkahyagil N, Imirzalioglu P, Karabulut E. Influence of previous provisional cementation on the bond strength between two definitive resin-based lut-ing and dentin bonding agents and human dentin. Oper Dent 2007;32:84-93. https://doi.org/10.2341/06-27
- Peutzfeldt A, Asmussen E. Influence of eugenol-containing temporary cement on efficacy of dentin-bonding systems. Eur J Oral Sci 1999;107:65-9. https://doi.org/10.1046/j.0909-8836.1999.eos107110.x
- Lingard GL, Davies EH, von Fraunhofer JA. The interaction between lining materials and composite resin restorative materials. J Oral Rehabil 1981;8:121-9. https://doi.org/10.1111/j.1365-2842.1981.tb00485.x
- Marshall SJ, Marshall GW Jr, Harcourt JK. The influence of various cavity bases on the micro-hardness of composites. Aust Dent J 1982;27:291-5. https://doi.org/10.1111/j.1834-7819.1982.tb05249.x
- Kanakuri K, Kawamoto Y, Matsumura H. Influence of temporary cement remnant and surface cleaning method on bond strength to dentin of a composite luting system. J Oral Sci 2005;47:9-13. https://doi.org/10.2334/josnusd.47.9
- Koka S, Ewoldsen NO, Dana CL, Beatty MW. The effect of cementing agent and technique on the retention of a CeraOne gold cylinder: a pilot study. Implant Dent 1995;4: 32-5. https://doi.org/10.1097/00008505-199504000-00005
- Dudley JE, Richards LC, Abbott JR. Retention of cast crown copings cemented to implant abutments. Aust Dent J 2008; 53:332-9. https://doi.org/10.1111/j.1834-7819.2008.00075.x
- Button GL, Barnes RF, Moon PC. Surface preparation and shear bond strength of the casting-cement interface. J Prosthet Dent 1985;53:34-8. https://doi.org/10.1016/0022-3913(85)90060-5
- Cobb DS, Vargas MA, Fridrich TA, Bouschlicher MR. Metal surface treatment: characterization and effect on compositeto- metal bond strength. Oper Dent 2000;25:427-33.
- Al-Zain SA. The effect of different metal cleaning methods on retention of cast crowns. Egypt Dent J 2006;52:2087-92.
- Mosharraf R. A simple method for cleaning zinc oxide-eugenol provisional cement residues from the intaglio surface of casting restorations. J Prosthet Dent 2004;91:200. https://doi.org/10.1016/j.prosdent.2003.12.001
- Homiak AW, Cook PA, DeBoer J. Effect of hygiene instrumentation on titanium abutments: a scanning electron microscopy study. J Prosthet Dent 1992;67:364-9. https://doi.org/10.1016/0022-3913(92)90248-9
- Speelman JA, Collaert B, Klinge B. Evaluation of different methods to clean titanium abutments. A scanning electron microscopic study. Clin Oral Implants Res 1992;3:120-7. https://doi.org/10.1034/j.1600-0501.1992.030304.x
- Brookshire FV, Nagy WW, Dhuru VB, Ziebert GJ, Chada S. The qualitative effects of various types of hygiene instrumentation on commercially pure titanium and titanium alloy implant abutments: an in vitro and scanning electron microscope study. J Prosthet Dent 1997;78:286-94. https://doi.org/10.1016/S0022-3913(97)70028-3
- Mengel R, Buns CE, Mengel C, Flores-de-Jacoby L. An in vitro study of the treatment of implant surfaces with different instruments. Int J Oral Maxillofac Implants 1998;13:91-6.
- Bain CA. An in vitro and in vivo evaluation of various implant- cleaning instruments. Quintessence Int 1998;29:423-7.
- Razzoog ME, Koka S. In vitro analysis of the effects of two air-abrasive prophylaxis systems and inlet air pressure on the surface of titanium abutment cylinders. J Prosthodont 1994; 3:103-7. https://doi.org/10.1111/j.1532-849X.1994.tb00136.x
- Augthun M, Tinschert J, Huber A. In vitro studies on the effect of cleaning methods on different implant surfaces. J Periodontol 1998;69:857-64. https://doi.org/10.1902/jop.1998.69.8.857
- Dario LJ. Implant angulation and position and screw or cement retention: clinical guidelines. Implant Dent 1996;5: 101-4. https://doi.org/10.1097/00008505-199600520-00005
- Kreisler M, Kohnen W, Christoffers AB, Gotz H, Jansen B, Duschner H, d'Hoedt B. In vitro evaluation of the biocompatibility of contaminated implant surfaces treated with an Er : YAG laser and an air powder system. Clin Oral Implants Res 2005;16:36-43.
Cited by
- Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation vol.6, pp.3, 2014, https://doi.org/10.4047/jap.2014.6.3.233
- 치과 보철용 크라운에 잔존하는 임시 시멘트의 용해액의 개발 vol.37, pp.1, 2017, https://doi.org/10.22805/jit.2017.37.1.012