References
- Kim WJ, Lee YD, Park HG, Lee JS, Jung SJ. Research on the mock-up fo CFT using 100 MPa high strength concrete and 800 MPa strength steel. Proceedings of the Korea Institute of Building Construction; 2011 May 20; Dong-eui University, Busan. Seoul(Korea): The Korea Institute of Building Construction; 2011. p. 35-7.
- Kim KY, Kim YS, Lee TG, Kang SJ, Kim MH. An experimental study on the evaluation of fire-resist performance of high-strength concrete filled steel tube column. Journal of the Architectural Institute of Korea. 2008 Aug;24(8):147-54.
- Park SH, Ryoo JY, Chung KS, Choi SM. An evaluation for the fire resistance of concrete-filled steel square tube columns under constant axial loads. Journal of Korean society of steel construction. 2007 Dec;19(6):703-14.
- Han HC, Kim YG, Kang SJ, Choi, SM. The 1st site application of non-fire-protection CFT columns. Journal of Korean society of steel construction. 2007 Jun;19(2):77-83.
- Cho KS, Kim HY, Kim HJ, Kwon IK. The study on the fire resistance performance of the CFT column according to the concrete compressive strength and load ratio. The 1st site application of non-fire-protection CFT columns. Journal of the Korean Institute of Fire Sci. & Eng. 2010 Apr;24(2):44-51.
- Kim JH, Kim TW, Chung KS, Kim DH, Choi IR. Application of unprotected CFT columns for Pohang/Gwangyang sports complex projects. Journal of Korean society of steel construction. 2011 Oct;23(5):49-53.
- Kim KY, Lee TG, Kim YS, Min CS, Kang YW. Evaluation of mechanical properties of CFT stub column at elevated temperature. Journal of the Architectural Institute of Korea. 2011 Jul;27(7):159-66.
- Venkatesh Kodur. Guidelines for fire resistant design of concrete-filled steel HSS columns-state-of-the-art and research needs. International Journal of Steel Structures. 2009 Sep;7(3):173-82.
- Song KC, Bang JS, Park SH, Chung KS, Choi, SM. An experimental study on fire resistance of concrete filled double skin tubular columns. Proceedings of the Architectural Institute of Korea.; 2009 Oct 23-24; Kangwon University. Seoul (Korea): The Architectural Institute of Korea; 2009. p. 433-6.
- Kim WJ, Kim HB, Kim KY, Kim YS. An experimental study on the fire resistant performance of the high strength concrete with loading and unloading test. Proceedings of the Korea Institute of Building Construction; 2009 Nov 14; ChungJu University. Seoul (Korea): The Korea Institute of Building Construction; 2009. p. 61-4.
- Seo I, Jun WC, Hong SB, Park HG, Kim WJ, Lee JS. An experimental study to evaluate compaction of high performance concrete for concrete filled tube. Proceedings of the Korea Concrete Institute; 2011 May 11-13; Jeju. Seoul (Korea): The Korea Concrete Institute; 2011. p. 553-4.
- Ko JW, Kim JJ, Lee SH, Moon HJ, Park SJ. An experimental study on the physical property change of high strength concrete for high-rise building before and after concrete pumping transfer. Journal of the Architectural Institute of Korea. 2010 Sep;26(9):71-8.
- Won JP, Jang CI, Lee SW, Kim HY, Kim WY. Fire reistance performance for hybrid fiber reinforced high strength concrete column member. Journal of the Korea Concrete Institute. 2008 Dec;20(6):827-32. https://doi.org/10.4334/JKCI.2008.20.6.827
- Kim KY, Lee HJ, Lee TG, Kim YS, Kang SJ. A study on the prediction of residual strength of concrete filled steel tube column without fire protective coating by unstressed heating. Journal of the Korean Institute of Fire Sci. & Eng. 2009 Jun;23(3):31-9.
Cited by
- An Experimental Study on the Ensuring the Fire Resistance Performance of Non-Refractory Coating CFT vol.15, pp.3, 2015, https://doi.org/10.5345/JKIBC.2015.15.3.273